KALITE SISTEM MERKEZ LABORATORIES Q&A DEPARTMENT ANALYSIS RESULTS Protocol Number : 1002014005582 Company / Address : SERENAY AMBALAJ SAN.TİC.LTD.ŞTİ. / ÇORLU / TEKİRDAĞ Matrix Producer / Trademark : Plastic Material (Cutlery) : -/- Customer Number : - Sample's Number Sample's Amount / Pieces Temperature at Sampling : : 100 Pieces + 50 Pieces x 2 + 50 Pieces x 2 / 5 :- Temperature at Receival Production Date / Expiry Date. Serial / Lot Number Process Type ::-/:-/: Regular :- Received by Receiving Place / Package Sample was taken on / at Sample was received on / at Analysis Starting and Ending Date :-/:: 10.03.2014 18:33 : 10.03.2014 / 19.03.2014 : 21.03.2014 Issuing Date Analysis Results L Limit Value Min Max ANALYSIS RESULTS CConformity Measurement Recovery Limit Uncertainty of Measurement Overall Migration(10 % 6 mg/kg 60 mg/kg + 7.2 mg/kg 60 mg/kg + 3.7 mg/kg 60 mg/kg + 8.5 mg/kg 60 mg/kg + 11.2 mg/kg 60 mg/kg + TS EN 1186-9 March 2006, TS EN 1186-3 March 2006 Ethanol)1.9 Overall Migration(20 % TS EN 1186-9 March 2006, TS EN 1186-3 March 2006 2.9 Ethanol) Overall Migration (3% Acetic Acid)3.9 TS EN 1186-9 March 2006, TS EN 1186-3 March 2006 Overall Migration(50 % TS EN 1186-9 March 2006, TS EN 1186-3 March 2006 4.9 Ethanol) Overall Migration(Fatty Foodstuffs- TS EN 1186-14, January 2004; TS EN 1186-3, March 2006 Ethanol)5.6.9 Overall Migration(Fatty Foodstuffs- TS EN 1186-14, January 11.4 mg/kg 60 mg/kg + 2004; TS EN 1186-3, March 2006 Isooctane)7.8.9 Copper Migration3.9 Barrium Migration3.9 Analysis Methods R Not detected 5 mg/kg + 0.5 mg/kg KSL AR-GE Not detected 1 mg/kg + 0.05 mg/kg KSL AR-GE N.B:This document is a translation of the original document written in Turkish No parts of this document can be used either alone or separately. Our documents may not be published or reproduced without our permission and unsigned documents are invalid. The results on the document belong only to the analyzed sample. Kalite Sistem Merkez Laboratories, Accreditation No:AB-0598-T, TSE Laboratory Document No:34/0017 Degirmen sok. Ar Plaza B Blok No:16 34742 Kozyatagi Kadikoy/Istanbul Tel: +216 445 27 27 (pbx) - Faks: +216 416 07 08 E-Mail: info@kalitesistem.com 1/2 KALITE SISTEM MERKEZ LABORATORIES Q&A DEPARTMENT ANALYSIS RESULTS Protocol Number : 1002014005582 Zinc Migration3.9 Not detected 25 mg/kg + 0.25 mg/kg KSL AR-GE Iron Migration3.9 Not detected 48 mg/kg + 0.5 mg/kg KSL AR-GE + 0.01 mg/L KSL AR-GE 0.6 mg/kg + 0.2 mg/kg KSL AR-GE 0.6 mg/kg + 0.005 mg/kg KSL AR-GE 0.05 Cobalt Migration3.9 Not detected mg/kg Lithium Migration3.9 Not detected Manganese Migration3.9 Not detected ¹ : Analysis Conditions: 10 % Ethanol , 40⁰C, 4 hours 2 : Analysis Conditions: 20 % Ethanol , 40⁰C, 4 hours 3 : Analysis Conditions: 3 % Acetic Acid , 40⁰C, 4 hours 4 : Analysis Conditions: 50 % Ethanol , 40⁰C, 4 hours 5 : Analysis Conditions: 95 % Ethanol , 40⁰C, 4 hours 6 : Reduction factor did not apply. 7 : Analysis Conditions: Isooctane , 20⁰C, 0,5 hour 8 : Reduction factor did not apply. 9 : Reference of Limit: TGK 2013/34, Commission Regulation (EU) No: 10/2011 NOTES : 1- All the information related to the sample belongs to the owner of the sample. 2- The sample was brought in closed packaging company to the laboratory. 3- Note of sample: (plastic knife 100 pieces, plastic forks 50 pieces x 2, plastic spoons 50 pieces x 2) samples were analyzed. Head of Instrumental Analysis Laboratory Dr. Çelik ERGENE Laboratories Coordinator N.Gülce DURMAZ N.B:This document is a translation of the original document written in Turkish 2/2
© Copyright 2024 Paperzz