ALB Emtia Raporu 27 03 2015

KALITE SISTEM
MERKEZ LABORATORIES
Q&A DEPARTMENT
ANALYSIS RESULTS
Protocol Number
: 1002014005582
Company / Address
: SERENAY AMBALAJ SAN.TİC.LTD.ŞTİ. / ÇORLU /
TEKİRDAĞ
Matrix
Producer / Trademark
: Plastic Material (Cutlery)
: -/-
Customer Number
: -
Sample's Number
Sample's
Amount / Pieces
Temperature at Sampling
: : 100 Pieces + 50 Pieces x 2 + 50 Pieces x 2 / 5
:-
Temperature at Receival
Production Date / Expiry Date.
Serial / Lot Number
Process Type
::-/:-/: Regular
:-
Received by
Receiving Place / Package
Sample was taken on / at
Sample was received on / at
Analysis Starting and Ending Date
:-/:: 10.03.2014 18:33
: 10.03.2014 / 19.03.2014
: 21.03.2014
Issuing Date
Analysis
Results
L Limit Value
Min
Max
ANALYSIS RESULTS
CConformity Measurement Recovery
Limit
Uncertainty of
Measurement
Overall
Migration(10 %
6 mg/kg
60 mg/kg
+
7.2 mg/kg
60 mg/kg
+
3.7 mg/kg
60 mg/kg
+
8.5 mg/kg
60 mg/kg
+
11.2 mg/kg
60 mg/kg
+
TS EN 1186-9 March 2006,
TS EN 1186-3 March 2006
Ethanol)1.9
Overall
Migration(20 %
TS EN 1186-9 March 2006,
TS EN 1186-3 March 2006
2.9
Ethanol)
Overall Migration
(3% Acetic Acid)3.9
TS EN 1186-9 March 2006,
TS EN 1186-3 March 2006
Overall
Migration(50 %
TS EN 1186-9 March 2006,
TS EN 1186-3 March 2006
4.9
Ethanol)
Overall
Migration(Fatty
Foodstuffs-
TS EN 1186-14, January
2004; TS EN 1186-3, March
2006
Ethanol)5.6.9
Overall
Migration(Fatty
Foodstuffs-
TS EN 1186-14, January
11.4 mg/kg
60 mg/kg
+
2004; TS EN 1186-3, March
2006
Isooctane)7.8.9
Copper
Migration3.9
Barrium
Migration3.9
Analysis Methods
R
Not detected
5 mg/kg
+
0.5 mg/kg
KSL AR-GE
Not detected
1 mg/kg
+
0.05 mg/kg
KSL AR-GE
N.B:This document is a translation of the original document written in Turkish
No parts of this document can be used either alone or separately. Our documents may not be published or reproduced without our
permission and unsigned documents are invalid. The results on the document belong only to the analyzed sample.
Kalite Sistem Merkez Laboratories, Accreditation No:AB-0598-T, TSE Laboratory Document No:34/0017
Degirmen sok. Ar Plaza B Blok No:16 34742 Kozyatagi Kadikoy/Istanbul
Tel: +216 445 27 27 (pbx) - Faks: +216 416 07 08 E-Mail: info@kalitesistem.com
1/2
KALITE SISTEM
MERKEZ LABORATORIES
Q&A DEPARTMENT
ANALYSIS RESULTS
Protocol Number
: 1002014005582
Zinc Migration3.9
Not detected
25 mg/kg
+
0.25 mg/kg
KSL AR-GE
Iron Migration3.9
Not detected
48 mg/kg
+
0.5 mg/kg
KSL AR-GE
+
0.01 mg/L
KSL AR-GE
0.6 mg/kg
+
0.2 mg/kg
KSL AR-GE
0.6 mg/kg
+
0.005 mg/kg
KSL AR-GE
0.05
Cobalt Migration3.9 Not detected
mg/kg
Lithium Migration3.9 Not detected
Manganese
Migration3.9
Not detected
¹ : Analysis Conditions: 10 % Ethanol , 40⁰C, 4 hours
2
: Analysis Conditions: 20 % Ethanol , 40⁰C, 4 hours
3
: Analysis Conditions: 3 % Acetic Acid , 40⁰C, 4 hours
4
: Analysis Conditions: 50 % Ethanol , 40⁰C, 4 hours
5
: Analysis Conditions: 95 % Ethanol , 40⁰C, 4 hours
6
: Reduction factor did not apply.
7
: Analysis Conditions: Isooctane , 20⁰C, 0,5 hour
8
: Reduction factor did not apply.
9
: Reference of Limit: TGK 2013/34, Commission Regulation (EU) No: 10/2011
NOTES : 1- All the information related to the sample belongs to the owner of the sample.
2- The sample was brought in closed packaging company to the laboratory.
3- Note of sample: (plastic knife 100 pieces, plastic forks 50 pieces x 2, plastic spoons 50 pieces x 2)
samples were analyzed.
Head of Instrumental Analysis Laboratory
Dr. Çelik ERGENE
Laboratories Coordinator
N.Gülce DURMAZ
N.B:This document is a translation of the original document written in Turkish
2/2