F4 PLUS F4 PLUS (AS05850) Apparecchiatura elettronica SCHEMA ELETTRICO E COLLEGAMENTI Electronic control unit ELECTRICAL CONNECTIONS I UK M1 LAMP LAMP M2 D3 D7 D8 D9 D10 D11 D12 D13 D14 D23 D24 M2 LED POWER PED START PHOTO STOP FCA M1 FCC M1 FCA M2 FCC M2 SAFETY-STOP D7 D23 D24 D3 POWER DIP1 RX P.S. TIME D10 D8 D9 D11 D12 D13 FORCE RUN M1-M2 TIME PED (NO) COM COM ANT M4 D14 F2T-160mA MEM2 MEM1 STOP (NC)/SAF.(8K2) COM FCC M2 (NC) FCA M2 (NC) FCC M1 (NC) FCA M1 (NC) PHOTO (NC) START (NO) 24Vac 0Vac EL 12Vac M1 230 Vac ~ NEUTRAL 230 Vac ~ PHASE EARTH EARTH 230Vac 40W MAX MOTOR OPEN MOTOR COM MOTOR CLOSE MOTOR OPEN MOTOR COM MOTOR CLOSE F1-5A 2 F4 PLUS I-UK SCHEMA ELETTRICO / ELECTRICAL CONNECTIONS 9 1 SW15 MEMO ON DIP2 PAUSE ON M3 F4 PLUS 3 I-UK COLLEGAMENTO ALIMENTAZIONE / POWER SUPPLY CONNECTION 2 PHASE NEUTRAL M2 INTERRUTTORE MAGNETOTERMICO OVERCURRENT CIRCUIT BREAKER 230Vac INTERRUTTORE DIFFERENZIALE RESIDUAL-CURRENT DEVICE PHASE NEUTRAL COLLEGAMENTO DI TERRA / EARTH CONNECTION 3 M2 COLLEGAMENTO LAMPEGGIANTE / FLASHING LIGHT CONNECTION ON OFF 9 LAMP LAMP M1 on off on off on off on off 230 Vac 40W max M1 LAMP M4 LAMP 4 4 DIP1_9 = ON 230 Vac 40W max F4 PLUS 4 I-UK COLLEGAMENTO SPIA DI SEGNALAZIONE / WARNING LIGHT CONNECTION 45 M4 M3 24Vac 0Vac 24Vac 3W MAX on off on off COLLEGAMENTO LUCE DI CORTESIA / COURTESY LIGHT CONNECTION 46 ON OFF 9 M1 LAMP LAMP 4 DIP1_9 = OFF on off 2 Min on off 2 Min COLLEGAMENTO DISPOSITIVI DI COMANDO / CONTROL DEVICES CONNECTION 47 PED (NO) COM START (NO) M3 COLLEGAMENTO ELETTROSERRATURA / ELECTRICAL LOCK CONNECTION M3 0Vac EL 12Vac 48 F4 PLUS 5 I-UK COLLEGAMENTO FOTOCELLULE / PHOTOCELLS CONNECTION M3 TX RX 24Vac 0Vac PHOTO (NC) M1 TX M1 M2 1 2 3 4 1 2 3 RX M2 1 2 3 4 1 2 3 COLLEGAMENTO FOTOCELLULE / PHOTOCELLS CONNECTION 10 4 ( AU01900 - AU01910 SINCRONIZZATE / SYNCHRONIZED ) M3 TX RX 12345 1234 24Vac 0Vac PHOTO (NC) TX RX 12345 1234 COLLEGAMENTO “DISPOSITIVO DI SICUREZZA” 8K2 / 8K2 “SAFETY DEVICE” CONNECTION ON M3 OFF 1 11 4 DIP2_1 = ON COM 8K2 STOP (NC)/SAF.(8K2) 8K2 COLLEGAMENTO STOP / STOP CONNECTION M3 ON COM OFF 1 STOP (NC)/SAF.(8K2) CONSULTARE IL MANUALE DELLE FOTOCELLULE PER MAGGIORI DETTAGLI / REFER TO THE PHOTOCELLS MANUAL FOR DETAILED CONNECTION DIAGRAMS 9 ( AU02000 SINCRONIZZATE / SYNCHRONIZED ) 4 DIP2_1 = OFF 12 31 4 F4 PLUS 6 I-UK IMPOSTAZIONE DI DEFAULT DIP1 / DIP1 DEFAULT SETTINGS 8 MANTENIMENTO BLOCCO OLEODINAMICO DISABILITATO HYDRAULIC BLOCK MAINTENANCE DISABLED MORSETTI 28-29 COME LUCE DI CORTESIA TERMINAL INPUTS N°28-29 AS COURTESY LIGHT INGRESSO PHOTO ABILITATO / PHOTO INPUT ENABLED FCC M2 DISABILITATO / FCC M2 DISABLED 7 FCC M2 ABILITATO / FCC M2 ENABLED FCA M2 DISABILITATO / FCA M2 DISABLED 6 FCA M2 ABILITATO / FCA M2 ENABLED FCC M1 DISABILITATO / FCC M1 DISABLED 5 FCC M1 ABILITATO / FCC M1 ENABLED FCA M1 DISABILITATO / FCA M1 DISABLED 4 FCA M1 ABILITATO / FCA M1 ENABLED COLPO D’ARIETE ABILITATO / HAMMER STROKE ENABLED 3 COLPO D’ARIETE DISABILITATO / HAMMER STROKE DISABLED LOGICA DI FUNZIONAMENTO PASSO PASSO CON STOP WORKING LOGIC - STEP BY STEP WITH STOP FOTOCELLULA IN APERTURA DISABILITATA PHOTOCELL ACTIVE DURING OPENING DISABLED 2 MANTENIMENTO BLOCCO OLEODINAMICO ABILITATO HYDRAULIC BLOCK MAINTENANCE ENABLED MORSETTI 28-29 COME LAMPEGGIANTE A LUCE FISSA TERMINAL INPUTS N°28-29 AS FIXED FLASHING LIGHT INGRESSO PHOTO DISABILITATO / PHOTO INPUT DISABLED ON 1 LOGICA DI FUNZIONAMENTO CONDOMINIALE / WORKING LOGIC - AUTOMATIC FOTOCELLULA IN APERTURA ABILITATA PHOTOCELL ACTIVE DURING OPENING ENABLED OFF 4 9 10 13 IMPOSTAZIONE DI DEFAULT DIP2 / DIP2 DEFAULT SETTINGS 14 OFF MORSETTI 23 COME STOP N.C. / TERMINAL INPUT N°23 AS N.C. STOP ON MORSETTI 23 COME COSTA 8K2 / TERMINAL INPUT N°23 AS 8K2 SAFETY DEVICE TRIMMER “FORCE” 15 31 MOVEMENT SPEED : 100% - THRUST FORCE: 25% VELOCITA’ ANTA : 100% - FORZA DI SPINTA : 25% MOVEMENT SPEED : 100% - THRUST FORCE: 100% VELOCITA’ ANTA : 100% - FORZA DI SPINTA : 100% F4 PLUS 7 I-UK TRIMMER “RUN TIME” 31 16 TEMPO DI LAVORO 2 SECONDI RUN TIME 2 SECONDS TEMPO DI LAVORO 103 SECONDI RUN TIME 103 SECONDS TRIMMER “P.S. TIME” 31 17 SFASAMENTO ANTE DISABILITATO LEAVES PHASE SHIFT TIME DISABLED SFASAMENTO ANTA 1 IN CHIUSURA: 20 SECONDI LEAF 1 CLOSING PHASE SHIFT TIME: 20 SECONDS TEMPO SFASAMENTO ANTA 2 IN APERTURA: FISSO 2 SECONDI LEAF 2 CLOSING PHASE SHIFT TIME: 2 SECONDS NOT ADJUSTABLE TRIMMER “PAUSE” 31 18 CHIUSURA AUTOMATICA DISABILITATA AUTOMATIC CLOSING DISABLED PAUSA 3 SECONDI PAUSE 3 SECONDS TEMPO PAUSA 103 SECONDI PAUSE 103 SECONDS Cod. AIC8753 - 05/2014 - Rev. 00 GI.BI.DI. S.r.l. Via Abetone Brennero, 177/B 46025 Poggio Rusco (MN) - ITALY Tel. +39.0386.52.20.11 Fax +39.0386.52.20.31 E-mail: comm@gibidi.com Numero Verde: 800.290156 w w w . g i b i d i . c o m
© Copyright 2024 Paperzz