albertone test catas - Accento Italian Contract Seatings

centro ricerche-sviluppo e laboratori prove
settori legno-arredo, ambiente e alimenti
CATAS S.p.A.
Iscr. Reg. Imprese Udine
nr. iscr. C.F. 01818850305
Reg. Impr. UD 20663
P. IVA : 01818850305
C.Soc. € 1.003.650,00 i.v.
Date received:
20-06-12
Date of issue:
10-07-12
Sede: Via Antica, 24/3
33048 S. Giovanni al Nat. UD
Tel. 0432.747211 r.a.
Fax 0432.747250
http://www.catas.com
e-mail: lab@catas.com
Filiale:
Via Braille, 5
20851 Lissone MB
Tel. 039.464567
Fax 039.464565
e-mail: lissone@catas.com
ACCENTO S.R.L.
VIALE TRIESTE 2/E
33044 MANZANO (UD)
ITALIA
Report consists of 2 test reports.
Defects before testing: None
Sample name:
ALBERT ONE PCL con basamento rovere
TEST REPORT N° 143332
Overall dimensions: 600 x 560 x 860 (h) mm
List performed tests:
1. Seat and back fatigue test EN 1728:2000
2. Leg sideways static load test EN 1728:2000
This document is validated by digital signature and time stamping in accordance
with the Italian laws and the European Directives which regulate the electronic
signature systems.
Managing Director
Dr. Andrea Giavon
The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test
report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be
reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.
Page 1 of 2
centro ricerche-sviluppo e laboratori prove
settori legno-arredo, ambiente e alimenti
CATAS S.p.A.
Iscr. Reg. Imprese Udine
nr. iscr. C.F. 01818850305
Reg. Impr. UD 20663
P. IVA : 01818850305
C.Soc. € 1.003.650,00 i.v.
Sede: Via Antica, 24/3
33048 S. Giovanni al Nat. UD
Tel. 0432.747211 r.a.
Fax 0432.747250
http://www.catas.com
e-mail: lab@catas.com
Filiale:
Via Braille, 5
20851 Lissone MB
Tel. 039.464567
Fax 039.464565
e-mail: lissone@catas.com
TEST REPORT N° 143332
Date of issue:
10-07-12
Sample weight:
Not determined
Sample name:
ALBERT ONE PCL con basamento rovere
Side view
Rear view
Bottom view
The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test
report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always
be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.
Page 2 of 2
centro ricerche-sviluppo e laboratori prove
settori legno-arredo, ambiente e alimenti
CATAS S.p.A.
Iscr. Reg. Imprese Udine
nr. iscr. C.F. 01818850305
Reg. Impr. UD 20663
P. IVA : 01818850305
C.Soc. € 1.003.650,00 i.v.
Sede: Via Antica, 24/3
33048 S. Giovanni al Nat. UD
Tel. 0432.747211 r.a.
Fax 0432.747250
http://www.catas.com
e-mail: lab@catas.com
Filiale:
Via Braille, 5
20851 Lissone MB
Tel. 039.464567
Fax 039.464565
e-mail: lissone@catas.com
TEST REPORT
143332 / 1
ACCENTO S.R.L.!
VIALE TRIESTE 2/E!
33044 MANZANO (UD)!
ITALIA
Date received:
20-06-12
Date of test:
27-06-12
Date of issue:
10-07-12
Sample name:
ALBERT ONE PCL con basamento rovere
Seat and back fatigue test EN 1728:2000
Seat and back fatigue test, clause 6.7
Test results:
Seat force
N
Back force
N
Number
of cycles
Remarks
1.000
300
200.000
No defects
Note:
The test has been carried out according to table 1 of EN 15373:2007, level 3 - severe.
This document is validated by digital signature and time stamping in accordance
with the Italian laws and the European Directives which regulate the electronic
signature systems.
Managing Director
Dr. Andrea Giavon
The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test
report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be
reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.
pag. 1/1
centro ricerche-sviluppo e laboratori prove
settori legno-arredo, ambiente e alimenti
CATAS S.p.A.
Iscr. Reg. Imprese Udine
nr. iscr. C.F. 01818850305
Reg. Impr. UD 20663
P. IVA : 01818850305
C.Soc. € 1.003.650,00 i.v.
Sede: Via Antica, 24/3
33048 S. Giovanni al Nat. UD
Tel. 0432.747211 r.a.
Fax 0432.747250
http://www.catas.com
e-mail: lab@catas.com
Filiale:
Via Braille, 5
20851 Lissone MB
Tel. 039.464567
Fax 039.464565
e-mail: lissone@catas.com
TEST REPORT
143332 / 2
ACCENTO S.R.L.!
VIALE TRIESTE 2/E!
33044 MANZANO (UD)!
ITALIA
Date received:
20-06-12
Date of test:
09-07-12
Date of issue:
10-07-12
Sample name:
ALBERT ONE PCL con basamento rovere
Leg sideways static load test EN 1728:2000
Leg sideways static load test, clause 6.13
Test results:
Sideways
horizontal force
N
Balancing
seat force
N
Number
of cycles
Remarks
760
1.800
10
No defects
Note:
The test has been carried out according to table 1 of EN 15373:2007, level 3 - severe.
This document is validated by digital signature and time stamping in accordance
with the Italian laws and the European Directives which regulate the electronic
signature systems.
Managing Director
Dr. Andrea Giavon
The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test
report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be
reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.
pag. 1/1