Core-Shell Technology Kinetex 1.7 µm UHPLC Columns The chosen core-shell brand to drive UHPLC performance to the next level Core-Shell Technology Core-Shell Technology Simply Advantageous The band broadening (wide peaks) and lengthy retention times of traditional fully porous products can limit your results. Now you can use the incredible efficiency levels of Kinetex Core-Shell Technology to achieve shorter run times, higher levels of sensitivity, and overall better UHPLC results. 1 Kinetex Core-Shell 1 Traditional Fully Porous 20 Get faster, better results with me! 15 10 APP ID 22805 mAU 4 2 2 5 4 3 3 0 28 30 32 34 Kinetex Core-Shell Traditional Fully Porous Phenomenex l WEB: www.phenomenex.com 36 min The First 1.7 µm Core-Shell Column Core-Shell Technology Upgrade the efficiency and performance of your current traditional sub2 μm column with a Kinetex 1.7 μm core-shell column. Extra resolution, higher peak capacities, and greater sensitivity are all within your reach with Kinetex Core-Shell Technology. Kinetex 1.7 µm XB-C18 % 66 19804 AU 0.035 0.030 0.025 Higher Resolution (between peaks 1 and 2) 1 138% 4 Higher Resolution (between peaks 5 and 6) 21% Higher Resolution (between peaks 7 and 8) 6 2 0.020 8 5 7 3 0.010 APP ID 19804 0.015 0.005 0 2 3 4 min Waters® ACQUITY® BEH 1.7 µm C18 AU 0.035 0.030 0.025 1 0.020 4 6 2 8 5 0.010 3 7 APP ID 19805 0.015 0.005 0 2 3 Conditions for both columns: Column: Kinetex 1.7 µm XB-C18 ACQUITY BEH 1.7 µm C18 Dimensions: 150 x 2.1 mm Mobile Phase: A: Milli-Q® Water B: Acetonitrile Gradient: Time (min) %B 0 30 5 100 Flow Rate: 0.5 mL/min Temperature: Ambient Detection: UV @ 210 nm (ambient) Backpressure: 891 bar (Kinetex) 935 bar (ACQUITY) Instrument: Waters ACQUITY UPLC® Sample: 1. Hydrocortisone 2. Cortisone 3. Corticosterone 4. Cortisone-21-Acetate 5. DHEA (Dehydroepiandrosterone) 6. 17-Hydroxyprogesterone 7. Deoxycorticosterone 8. Progesterone Comparative separations may not be representative of all applications. Phenomenex 4 l WEB: www.phenomenex.com min Superior and Faster Resolving Power Core-Shell Technology The increased efficiency of Kinetex 1.7 μm allows you to use shorter columns for faster run times while keeping optimal performance. Now it’s time for you to challenge your difficult separations with the superior efficiency and resolving power of a Kinetex 1.7 μm core-shell column. Faster analysis, better sensitivity, and overall better resolution! Kinetex 1.7 µm C18 APP ID 20686 Intensity, cps 1.4e4 7000 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 min 1.0 1.2 1.4 1.6 1.8 min 1.0 1.2 1.4 1.6 1.8 min 5500 APP ID 20686 Intensity, cps Fully Porous 3.5 µm C18 0 0.2 0.4 0.6 0.8 Fused-Core® 2.7 µm C18 6000 APP ID 20686 Intensity, cps 1.15e4 0 0.2 0.4 0.6 0.8 Conditions for all columns: Columns: Fully porous 3.5 µm C18 (50 x 2.1 mm) Fused-Core 2.7 µm C18 (50 x 2.1 mm) Kinetex 1.7 µm C18 (30 x 2.1 mm) Mobile Phase: A: 10 mM Ammonium Formate B: Acetonitrile Gradient: Time (min) %B 0 5 2 100 2.1 5 Flow Rate: Temperature: Detection: Sample: 0.7 mL/min 22 °C MS/MS (SCIEX API 4000™) Lorazepam glucuronide Comparative separations may not be representative of all applications. Phenomenex l WEB: www.phenomenex.com Core-Shell Technology Trust / Consistency Highly sensitive UHPLC separations are dependent upon consistent quantitation and consistent results. With the reliability of the Kinetex columns and media batches, you no longer have to settle for the inconsistent results of inferior products that exist on the market. Our highest standards of quality will ensure that you are fully satisfied with each and every Kinetex column! mAU 60 Batch 12 5 6 50 APP ID 22782 7 40 2 30 20 1 4 3 10 0 0 1 2 3 min 4 mAU 60 Batch 13 5 6 50 7 APP ID 22782 40 2 30 20 1 4 3 10 0 0 1 2 3 min 4 mAU 60 Batch 14 5 6 50 APP ID 22782 7 40 2 30 20 1 4 3 10 0 0 1 2 3 4 Detection: UV @ 254 nm (ambient) Sample: 1. Uracil 2. Pindolol 3. Chlorpheniramine 4. Nortriptyline 5. 3-Methyl-4-Nitrobenzoic acid 6. 5-Methyl Salicyl Aldehyde 7. Hexaphenone Conditions same for all batches: Column: Kinetex 1.7 µm F5 Dimensions: 50 x 4.6 mm Mobile Phase: A: 0.1 % Formic Acid in Water B: 0.1 % Formic Acid in Acetonitrile Gradient: 5-95 % B over 5 min Flow Rate: 1.85 mL/min Temperature: 30 ˚C Comparative separations may not be representative of all applications. Phenomenex l WEB: www.phenomenex.com min Upgrade from Hybrid Materials Core-Shell Technology By upgrading from fully porous hybrid UHPLC columns to the Kinetex 1.7 μm EVO C18, you can keep the pH stability but gain much greater performance. With the core-shell advantage at your disposal your new methods will be faster and more sensitive, leaving room for greater productivity. Berberine Standard mAU 120 Kinetex 1.7 µm EVO C18 57% Increase in Peak Height Response 100 Waters® ACQUITY® BEH 1.7 µm C18 80 60 APP ID 23111 and 23109 40 Greater Resolution of Impurities 20 0 1 2 3 Conditions for both columns: Column: Kinetex 1.7 µm EVO C18 ACQUITY BEH 1.7 µm C18 Dimensions: 50 x 2.1 mm Mobile Phase: A: 0.1 % Formic Acid in Water B: 0.1 % Formic Acid in Methanol Gradient: Time (min) %B 0 2 5 95 Flow Rate: 0.5 mL/min Temperature: 30 º C Detection: UV @ 254 nm (ambient) Sample: 1. Berberine Comparative separations may not be representative of all applications. Phenomenex l WEB: www.phenomenex.com min Core-Shell Technology UHPLC Compatible Kinetex columns are compatible with ALL UHPLC Instruments. Kinetex on Agilent® 1290 Kinetex on JASCO® X-LC Kinetex on Shimadzu® Nexera® Kinetex on Waters® ACQUITY UPLC® Need help installing your Kinetex column? www.phenomenex.com/kinetex/technicalresources Phenomenex l WEB: www.phenomenex.com Utilizing Powerful Selectivities Core-Shell Technology With the combination of the novel Kinetex EVO C18, F5, and Biphenyl selectivities at your disposal, reversed phase UHPLC method development can be taken to the next level. With its exceptional peak shape for basic compounds, the EVO C18 is a dynamic tool that gives core-shell high performance while allowing retention to be enhanced by adjusting the pH of the mobile phase. Kinetex 1.7 µm EVO C18 mAU 800 TMS APP ID 23079 pH 2.5 600 TMS 400 EVO 200 1 C18 0 1 2 3 4 5 6 7 min Utilize High pH Stability of EVO C18 to Enhance Retention Kinetex 1.7 µm EVO C18 mAU 700 600 TMS pH 10 TMS APP ID 23082 500 400 300 1 EVO 200 C18 100 0 0 1 2 3 4 5 6 Conditions for all columns same except where noted: Column: Kinetex 1.7 µm EVO C18 Dimensions: 50 x 2.1 mm Part No.: 00B-4726-AN Mobile Phase: A: 20 mM Potassium phosphate (pH 2.5) B: Methanol Mobile Phase: A: 20 mM Potassium phosphate (pH 10) B: Methanol Gradient: Time (min) % B 0 5 8 90 Flow Rate: 0.5 mL/min Temperature: 30 º C Detection: UV @ 210 nm (ambient) Sample: 1. Fluvoxamine Phenomenex l WEB: www.phenomenex.com 7 min Mo Orth Sol Core-Shell Technology Next to the EVO C18, the orthogonal Kinetex F5 and Biphenyl will drive enhancement of reversed phase methods with their versatile array of interaction mechanisms. Varying degrees of electrostatic, aromatic, reversed phase, steric, and hydrogen bonding between the F5 and Biphenyl mean that these two stationary phases are both excellent alternatives to a C18. Additionally the F5 is known for its ability to separate isomeric species, while the pi electron cloud created by the dual ring of the Biphenyl phase acts like a weak negative charge and aids basic compound retention. Kinetex 1.7 µm F5 mAU 700 600 500 400 300 200 100 0 F F F pH 2.5 F TMS TMS F5 0 APP ID 23080 F 1 1 2 3 4 5 6 7 min Kinetex 1.7 µm Biphenyl mAU 700 600 500 TMS pH 2.5 TMS APP ID 23081 ove to hogonal lutions! Utilizing Powerful Selectivities 400 300 Biphenyl 200 1 100 0 0 1 2 3 4 5 Conditions for all columns: Column: Kinetex 1.7 µm F5 Kinetex 1.7 µm Biphenyl Dimensions: 50 x 2.1 mm Part No.: Kinetex F5: 00B-4722-AN Kinetex Biphenyl: 00B-4628-AN Mobile Phase: A: 20 mM Potassium phosphate (pH 2.5) B: Methanol Gradient: Time (min) % B 0 5 8 90 Flow Rate: 0.5 mL/min Temperature: 30 º C Detection: UV @ 210 nm (ambient) Sample: 1. Fluvoxamine Phenomenex l WEB: www.phenomenex.com 6 7 min Protect any UHPLC Column Core-Shell Technology Protect your column, including Kinetex coreshell columns, from damaging contaminants and microparticulates with the SecurityGuard ULTRA guard cartridge system! UHPLC Column Protection • Simple to use • Extend column lifetime • Pressure rated to 20,000 psi (1,378 bar) • Fits virtually all manufacturers’ columns 2.1 to 4.6 mm ID From Injection SecurityGuard ULTRA Guard Cartridge System (Cartridge connected to Holder) Cartridge Holder SecurityGuard™ ULTRA Frit UHPLC Column to Detector Material Chamber } Compounds of Interest Contaminants and Particulates See it in action: www.phenomenex.com/SecurityGuardULTRA Phenomenex l WEB: www.phenomenex.com Core-Shell Technology Kinetex Phase Selection Phase Best Use pH Stability EVO C18 Robust reversed phase methods even in alkaline conditions with improved peak shape for polar basic compounds 1 - 12 C18 All purpose phase that offers the hydrophobic retention and methylene selectivity chromatographers expect from a C18 column 1.5 - 8.5* XB-C18 C18 phase with protective butyl side chains for improved peak shape for basic compounds under neutral and acidic conditions 1.5 - 8.5* C8 USP L7 phase that provides less hydrophobic and methylene selectivity than a C18 1.5 - 8.5* F5 Highly reproducible pentafluorophenyl propyl phase that offers a unique combination of polar, hydrophobic, aromatic, and shape selectivity 1.5 - 8.5 Biphenyl 100% aqueous stable and allows for excellent reversed phase retention and enhanced polar and aromatic selectivity 1.5 - 8.5* phase chemistry that allows for greater retention and separation Phenyl-Hexyl Reversed of aromatic hydrocarbons HILIC Unbonded silica phase for HILIC conditions to provide selectivity for polar compounds 1.5 - 8.5* 2.0 - 7.5 *pH stability under gradient conditions. pH stability is 1.5-10 under isocratic conditions. Ordering Information 50 x 2.1 100 x 2.1 150 x 2.1 SecurityGuard™ ULTRA Cartridges‡ 3/pk –– 00B-4726-AN 00D-4726-AN 00F-4726-AN AJ0-9298 –– –– 00A-4498-AN 00A-4475-AN 00A-4499-AN 00A-4474-AN –– 00B-4722-AN 00B-4628-AN 00B-4498-AN 00B-4475-AN 00B-4499-AN 00B-4474-AN 00B-4500-AN 00D-4722-AN 00D-4628-AN 00D-4498-AN 00D-4475-AN 00D-4499-AN 00D-4474-AN 00D-4500-AN 00F-4722-AN 00F-4628-AN 00F-4498-AN 00F-4475-AN 00F-4499-AN –– 00F-4500-AN AJ0-9322 AJ0-9209 AJ0-8782 AJ0-8782 AJ0-8784 AJ0-8786 AJ0-8788 for 2.1 mm ID 1.7 μm Minibore Columns (mm) Phases 30 x 2.1 EVO C18 F5 Biphenyl XB-C18 C18 C8 HILIC Phenyl-Hexyl ‡ SecurityGuard ULTRA Cartridges require holder, Part No.: AJ0-9000 If you are not completely satisfied with Kinetex core-shell columns, send in your comparative data to a similar product within 45 days and keep the column for FREE. Phenomenex l WEB: www.phenomenex.com Australia t: +61 (0)2-9428-6444 f: +61 (0)2-9428-6445 auinfo@phenomenex.com Austria t: +43 (0)1-319-1301 f: +43 (0)1-319-1300 anfrage@phenomenex.com Belgium t: +32 (0)2 503 4015 (French) t: +32 (0)2 511 8666(Dutch) f: +31 (0)30-2383749 beinfo@phenomenex.com Canada t: +1 (800) 543-3681 f: +1 (310) 328-7768 info@phenomenex.com China t: +86 (0)20 2282-6668 f: +86 (0)20 2809-8130 chinainfo@phenomenex.com Denmark t: +45 4824 8048 f: +45 4810 6265 nordicinfo@phenomenex.com Finland t: +358 (0)9 4789 0063 f: +45 4810 6265 nordicinfo@phenomenex.com France t: +33 (0)1 30 09 21 10 f: +33 (0)1 30 09 21 11 franceinfo@phenomenex.com Germany t: +49 (0)6021-58830-0 f: +49 (0)6021-58830-11 anfrage@phenomenex.com India t: +91 (0)40-3012 2400 f: +91 (0)40-3012 2411 indiainfo@phenomenex.com Ireland t: + 353 (0)1 247 5405 f: +44 1625-501796 eireinfo@phenomenex.com Italy Norway t: +47 810 02 005 f: +45 4810 6265 nordicinfo@phenomenex.com Puerto Rico t: +1 (800) 541-HPLC f: +1 (310) 328-7768 info@phenomenex.com Spain t: +34 91-413-8613 f: +34 91-413-2290 espinfo@phenomenex.com Sweden t: +39 051 6327511 f: +39 051 6327555 t: +46 (0)8 611 6950 f: +45 4810 6265 Luxembourg t: +31 (0)30-2418700 f: +31 (0)30-2383749 nlinfo@phenomenex.com United Kingdom t: +44 (0)1625-501367 f: +44 (0)1625-501796 ukinfo@phenomenex.com italiainfo@phenomenex.com Mexico t: 001-800-844-5226 f: 001-310-328-7768 tecnicomx@phenomenex.com nordicinfo@phenomenex.com USA t: +1 (310) 212-0555 f: +1 (310) 328-7768 info@phenomenex.com The Netherlands t: +31 (0)30-2418700 f: +31 (0)30-2383749 nlinfo@phenomenex.com All other countries Corporate Office USA t: +1 (310) 212-0555 f: +1 (310) 328-7768 info@phenomenex.com New Zealand t: +64 (0)9-4780951 f: +64 (0)9-4780952 nzinfo@phenomenex.com www.phenomenex.com BR39820216_I_2 Phenomenex products are available worldwide. For the distributor in your country, contact Phenomenex USA, International Department at international@phenomenex.com Terms and Conditions Subject to Phenomenex Standard Terms & Conditions, which may be viewed at www.phenomenex.com/TermsAndConditions. Trademarks Kinetex is a registered trademark and SecurityGuard is a trademark of Phenomenex. Waters, ACQUITY, and UPLC are registered trademarks, and BEH Technology is a trademark of Waters Corporation. Agilent is a registered trademark of Agilent Technologies, Inc. Shimadzu and Nexera are registered trademarks of Shimadzu Corporation. JASCO is a registered trademark of JASCO, Corporation. Fused-Core is a registered trademark of Advanced Materials Technology, Inc. API 4000 is a trademark of AB SCIEX Pte. Ltd. AB SCIEX is being used under license. Milli-Q is a registered trademark of Merck KGaA, Darmstadt, Germany. Disclaimer Phenomenex is not affiliated with Advanced Materials Technology, Agilent Technologies, JASCO, or Waters Corporation. Comparative separations may not be representative of all applications. Kinetex EVO is patented by Phenomenex. U.S. Patent Nos. 7,563,367 and 8,658,038 and foreign counterparts. © 2016 Phenomenex, Inc. All rights reserved.
© Copyright 2024 Paperzz