LumenOptix How To Design a Better Fixture

How To
Design A
Better Fixture...
Start With A Better Lamp
Goal: Use a powerful lamp that maintains light output, is rated for 35,000 hours, and is small in diameter
to allow the design of accurate reflectors.
Millions of T5HO lamps have been installed over the past 10 years. They have proven to be a cost-effective reliable light source and are
optimal for extremely efficient reflector designs. Additionally, T5HO lamps maintain a higher percentage of their lumen output over time.
T=Tubular Diameter in 1 / 8 th of an Inch
94% Lumen Maintenance
T5
94 %
1
T12 = 1 /2Лќ Diameter
T8 =1Лќ Diameter
T5 =5/8Лќ Diameter
Percent Rated Lumens
100
LumenOptix T5 Lamps are
rated for 35,000 Hours.
Based on 12 hours per start. ANSI testing “hour rating” is the
point at which 50% of lamps have failed.
80
60
400W Metal
Halide
40
45 %
20
5
10
15
Burning Hours (thousands)
20
Notice how 400 watt metal halide lamps dip below 50% light
output at 15,000 hours.
Thermal Management:
Goal: Use thermal management techniques to design a fixture for optimal efficiency and peak lumen output.
A popular misconception is that room temperature has to be 35˚C / 95˚F for T5 lamps to peak their lumen output (5,000 lumens). The reality is that the maximum light output of a T5 lamp is when the mercury “cold spot” is 48˚C/118˚F. LumenOptix applies thermal management techniques to assure
that fixtures operate at ideal temperatures.
100%
90%
80%
70%
The lamp cold spot is located 1/8” in from the end of lamp and is where excess mercury is stored when lamp is off.
Efficiency
60%
50%
40%
30%
20%
10%
LumenOptix further manages
heat with aluminum ballast
compartments
Misconception
Reality
Thermal
Management Design
Total Luminaire
Efficiency
T5HO Cold Spot
Temperature
Test 1
81.4%
60.9ЛљC / 142ЛљF
Test 2
86.7%
57.0ЛљC / 135ЛљF
Test 3
96.2%
48.5ЛљC / 119ЛљF
65ЛљC
60ЛљC
55ЛљC
50ЛљC
45ЛљC
40ЛљC
35ЛљC
30ЛљC
25ЛљC
20ЛљC
0%
Lab test for the identical fixture, ballast, and lamp produced the
results listed. The only variance was the amount of lamp venting.
Understanding Reflector Design
Goal: Maintain Beam Spread, Minimize bounces, get the maximum light out of fixture.
Fixture efficiency, by definition, is the percentage of total light output of the fixture divided into total light output of just the bare
A. Bare
Run
B. on
Luminaire
Run
lamps.Lamp
The measurements
are taken
a Gonio photometer
and represent how much of the total light gets trapped in the fixture.
One Bounce and Out
360Лљ
30%
trapped
10,000
Lumens
in
fixture
=
20,000 Lumens
70% efficient
With 95% reflective material, each bounce costs 5% light output
10,000
Lumens
20,000
Lumens
-5%
360Лљ
50%
-5%
-5%
-5%
96% efficient
= .50 only
= 4% trapped in fixture
95%
LumenOptix Competitor precision less efficient, optics multiple bounces
85%
Using “Ray Trace” computer modeling, LumenOptix traces 29,000,000 theoretical rays to calculate beam and efficiency.
Narrow Beam
Wide Beam
Yellow Rays =
0 Bounce
Green Rays =
1 Bounce
Red Rays =
More than 1 Bounce
the difference between success and Failure
Goal: Use precision tooling to ensure reflector design matches fabrication.
LumenOptix’s reflector designs are engineered to the tenth of a degree for bending angles, and to the thousandth of an inch
for facet length. If fabrication tolerance does not match design, theoretical efficiencies are not realized. Below was a real world
“miss”. One angle missed by 2˚ and the reflector spacing criteria was out of spec. LumenOptix controls this situation by using
precise CNC machinery to produce reflectors.
Compromised
at 152Лљ
Specified
at 154Лљ
Use the Proper Reflector Material
Goal: Total Reflectivity —The sum of diffuse and specular reflectivity.
ela
and
1C
To make accurate reflectors you need to minimize diffusion. Diffusion is
when light scatters randomly in a material. LumenOptix uses specular
material that is not only highly reflective, but is also minimally diffuse.
dela
Can
.95
95% Reflective
Laser Shows Diffusion
Enhanced reflector material
Standard specular material
Standard diffuse
material: laser reflects but scatters
Very accurate specular material: Beams reflect without
scattering
APPLICATION Efficiency / BEAM CONTROL
Goal: Eliminating wasted light in the application, drives further efficiency.
Most lighting manufacturers offer a generic, one-size-fits-all fixture that can provide up to 50% energy savings. LumenOptix
delivers lighting systems that are optimized for savings, given a specific facility. By creating a unique, application-specific system
for each facility, LumenOptix has delivered savings up to 75% AND improved light levels (15-25% over anything a competitor can
offer).
Narrow beam
48'
Medium beam
Wide areas, low ceiling
Neutral Area
Usable Light
Neutral Area
Typical metal halide round
beam/wastes light
Wasted Light
Wasted Light
Neutral Area
Usable Light
Linear fixture makes more sense for aisles
Wasted Light
End Result
Goal: More Foot-Candles for less watts — true efficiency.
Tight beam control
2 lamp 117w fixture mounted at 33' on 36' centers. You can see where the aisles will be prior to rack
assembly—notice the accurate beam control.
Same wattage
twice the light!
Notice the sharp cutoff angles vs. the competitors.
LumenOptix aisle = 21 foot candles
Competitor aisle = 10 foot candles
Better control translates into less energy by
eliminating wasted light.
Competitor Demo
10 foot candles at floor
Demo /using narrow beam
21 foot candles at floor
SAME light
HALF THE wattage!
Half the energy for the same light, 46 ft. mount height.
Competitor
LumenOptix
LumenOptix
(Existing foreground at 46’ mounting) - 465 Watt/HiD System
Competitor
226 Watt
117 Watt
234 Watt
234 Watt
Their 6 lamp T8—
6 footcandles В­
Our 2 lamp T5HO Narrow Beam —
11 footcandles В­
Our 4 lamp T5HO Narrow Beam —
24 footcandles В­
Their 4 lamp T5HO
Cookie Cutter —
12 footcandles В­
Sunny Delight
(Food Processing)
Case # 00600-08
Monthly KwH Savings
63%
Annual Energy Savings
$160,622 Utility Incentive
$36,450
West Marine
(Distribution)
Case # 00606-08
Payback
< 13 months
Annual Energy Savings
$151,000
Compounded Annual Return
23%
Ace Hardware
(Distribution)
Case # 00617-07
Annual Savings
$120,154
Energy Savings
70%
Sea Gull Lighting
(Distribution)
Case # 00919-07
Annual Savings vs. Metal Halides $80,000
Annual Savings vs. T8 Fluorescent System
$26,000
CSX LOCOMOTIVE SHOP
(Maintenance)
Energy Savings
with 8 lamp fluorescent high bay
46Вґ mounting height required
LumenOptix precision optics
Case # 00616-07
65%
WESTINGHOUSE
LIGHTING
SOLUTIONS
LumenOptix
meets the specified foot candle levels using less
energy and fewer lamps than any other manufacturer.
The choice is not T5 or T8,
the choice is which is the better investment.
Helpful Industry Terms
Industrial lighting Glossary
A
B
ADA - Americans with Disabilities Act as it relates to lighting
products requires that wall mounted lighting (sconces) not
extend more than 4” from the wall unless positioned over a
certain height.
AMPERE (AMP) – Standard unit for measuring the strength
of an electric current defined as rate of flow of charge.
ANSI – American National Standards Institute. The
coordinator of standards, including lighting standards,
on a national level. It is composed of trade organizations,
technical societies, professional groups, consumer
organizations, as well as company members.
ARC TUBE – A tube in which a current traverses a gas
between two electrodes.
ASHRAE –American Society of Heating, Refrigeration, and Air
Conditioning Engineers sets guidelines regarding energy
usage and system design.
BALLAST – Electrical device used with fluorescent and
high intensity discharge lamps to provide the necessary
starting and operating power conditions.
BALLAST CYCLING – The ballast turning lamps on and
off (cycles) due to the overheating of the thermal switch
C
inside the ballast. This may be due to lamp misapplication,
improper voltage, high ambient temperature, or the early
stage of ballast failure.
BALLAST, COLD WEATHER – A ballast designed to provide
sufficient starting voltage for fluorescent lamps in cold weather,
generally down to 20Лљ F.
MADE
IN
USA
BALLAST, DIMMING – A ballast which when used together
with a dimmer control will vary the light output of a lamp.
BALLAST, ELECTRONIC – A ballast made of electronic
components to start and operate the lamp.
BALLAST COVER – A component installed to cover ballast
and wiring also referred to as a channel cover or wireway cover.
BALLAST EFFICIENCY FACTOR (BEF) – The ballast factor
divided by the input power of the ballast. The higher the BEF,
the more efficient the ballast.
BALLAST FACTOR (BF) – A light loss factor applied to
lighting calculations for fluorescent lamps. Lamps operated
by a ballast with a BF of 0.90 will provide 90 percent of their
rated light output (lumens). BFs between 0.85 and 1.0 are the
most common.
BALLAST, MAGNETIC – A ballast using a core and coil
transformer to start and operate the lamp.
BI-LEVEL SWITCHING – A fixture or string of fixtures set
up to operate at two levels, which usually switch half the lamps
off based on programming a sensor, timer or 2nd circuit.
CANDELA – A unit of luminous intensity.
CANDLEPOWER – The luminous intensity of a light source
expressed in candelas. Candlepower is a measurement of
light intensity. It is used as a measurement of beam intensity
at various angles from reflector lamps or fixtures.
CHANNEL – A fluorescent fixture composed of only a
wireway and cover to hold the ballast and sockets. Also called
a strip light.
CLASS “P” – A safety feature that switches the ballast off if
the ballast case temperature rises above 105Лљ F.
COEFFICIENT OF UTILIZATION (CU) – A percentage
commonly applied to indicate the efficiency of a luminaire
determined by room size and mounting height.
COLOR RENDERING INDEX (CRI) – A measure of
the color shift created by artificial light. Color rendering is
measured on a scale from zero to 100, with natural outdoor
light having a CRI of 100. The higher the index, the more
true to life colors appear.
COLOR TEMPERATURE – Expressed in degrees Kelvin,
color temperature indicates the color of a light source. For
example, incandescent lamps are approximately 2700Лљ Kelvin
(KЛљ) and appear yellowish. Fluorescent range from 2700Лљ
Kelvin up to 7500˚ with those at the high end appearing bluewhite, or “cool”. Rather than being the physical temperature of
the light itself, the Kelvin number refers to the color a theoretical “black body” would be if heated to that temperature.
COMPACT FLUORESCENT – A small fluorescent lamp that
is often used as an alternative to incandescent lighting. The lamp
life is about 10 times longer than incandescent lamps and is
3-4 times more efficacious. Also referred to as PL, DL, CFL,
or BIAX lamps.
CONDUIT – A metal tube or pipe used as an enclosure to
protect wires.
CONSTANT-WATTAGE AUTOTRANSFORMER (CWA)
– A common type of ballast used for HID lamps which
maintains constant power wattage to the lamp when input
voltage fluctuates.
Glossary continued on back page
Call 1-800-671-6799 (EST) • Outside the United States: 215-671-2029
info@LumenOptix.com • www.LumenOptix.com
LumenOptix, LLC, Philadelphia, PA 19154-1029, U.S.A.
CONTRAST – The relationship between the
D brightness of an object and its surroundings.
E
F
G
H
CORD SET – Electrical cord which is wired
to a fixture. See also Whip
CSA – Canadian Standards Association is
similar to UL. Dual listing is available with both
entities as either cUL or CSA/US making products acceptable throughout North America.
CUTOFF ANGLE – The angle from vertical
at which a reflector, louver, or other shielding
device cuts off direct visibility of a lamp.
DAMP LOCATION FIXTURES – Fixtures
suitable for areas that do not come in direction
contact with water, including partially protected
canopies and overhangs.
DISTRIBUTION CURVE – A graphic representation of candela values.
DISABILITY GLARE – Bright light that impairs vision also known as veiling luminance.
DISCOMFORT GLARE – Glare that is uncomfortable and distracting, yet less obvious than
disability glare.
EFFICACY – A non-linear relationship of
efficiency. For instance, lumens per watt, miles
per gallon, etc.
ENHANCED ALUMINUM REFLECTOR
– Highly polished reflectors designed to
control light and improve efficacy.
EPACT 2005 – Energy Bill passed by
Congress designed to reduce energy
consumption through product regulation
and incentive programs.
FIXTURE – Any type of luminaire.
FIXTURE SCHEDULE – A form that lists
all luminaires used on an installation. The
list typically includes all the fixture types and
quantities.
FLOODLIGHTING – A type of outdoor
lighting commonly used in parking lots or
sports fields
FLUORESCENT LAMP – A light source
consisting of a tube filled with argon,
along with krypton or other inert gas. When
electrical current is applied, the resulting
arc emits ultraviolet radiation that excites
the phosphors on the inside of the lamp wall,
causing them to radiate visible light.
FOOTCANDLE (FC) – A unit of direct illumination; the amount of light produced by one
candela on a square foot of surface, every part
of which is one foot from the candle. A lumen
per square foot.
FOOTCANDLE, MAINTAINED – Illumination
level calculated using light loss factors, including lamp lumen depreciation (LLD), luminaire
dirt depreciation (LDD) and other factors which
reduce the light levels.
FUSE – An electrical safety device which
will break the circuit in the event of a current
overload.
GASKET – A devise used to form a seal
to limit light leaks or the penetration of dust,
water, oil or other contaminants.
GLARE – The effect of brightness or differences in brightness within the visual field, sufficiently high to cause annoyance, discomfort
or loss of visual performance.
Harmonics (THD) – Most electronic ballasts
provide reduced harmonics providing <10%
power quality distortion.
HID – High Intensity Discharge. Generic term
used to describe mercury vapor, metal halide,
high pressure sodium, and (informally) lowpressure sodium light sources and luminaires.
HIGHBAY – Typically pertains to general
warehouse lighting which is 15’ or higher.
HIGH OUTPUT (HO) – A lamp designed for
use with an 800 milliampere (MA) ballast; will
usually operate at low temperatures (down to
zero) while still producing high light levels.
I
L
HIGH PRESSURE SODIUM – A high-intensity
discharge (HID) lamp whose light is produced
by radiation from sodium vapor (and mercury).
HOUSING – The body of the fixture that holds
the electrical and decorative components.
IALD –International Association of Lighting
Designers.
IBEW – International Brotherhood of Electrical
Workers.
IES (IESNA) - Illumination Engineering
Society of North America.
ILLUMINANCE – A photometric term that
quantifies light incident on a surface or plane.
Illuminance is commonly referred to as light
level. It is expressed as lumens per square foot
(footcandles), or lumens per square meter (lux).
INDUSTRIAL – A strip light with an attached
reflector.
INSTANT-START – A light source that will
start from a high voltage with no preheating of
the electrodes. Instant-start lamps cannot be
interchanged with rapid-start lamps.
ITL –Independent Testing Laboratories.
Lighting manufacturers use this laboratory to
conduct photometric tests for luminaires.
KNOCKOUT (KO) – A portion of the metal
enclosure which has been partially cut out. It
can be easily removed to attach wires, convenience outlets, conduit fittings, etc.
LAMP – Industry term for commercial light bulb.
LAMP LIFE – Rated life of a lamp, as established through laboratory testing during which
a sample group of lamps is burned, including
being subjected to a scheduled number of starts
per day. The length of time required for half the
lamps to fail is the rated lamp life.
LAMP LUMEN DEPRECIATION (LLD) –
Mean lumens divided by initial lumens.
LAY-IN TROFFER – A fluorescent fixture,
which lays into a grid ceiling. Nema type G.
L.E.D. – (Light Emitting Diodes) Efficient
lamp features extended life and environmental
benefits.
LENS – Cover for the face of a lighting fixture;
diffuses or focuses light passing through it and
protects internal components. Also called
“refractor” or “ diffuser”. Usually make of glass
or acrylic, clear or prismatic.
LIGHT LOSS – Used to calculate or project
lighting system performance after a given period
of time under certain conditions; takes into
account variations in temperature and voltage,
dirt, lamp depreciation and maintenance. Also
called “maintenance factor”.
LOWBAY – Typically for mezzanine lighting
which is 15’ or lower.
LOW PRESSURE SODIUM LAMP – Lamp
where arc is passed through gaseous sodium
producing monochromatic light (589-589.6 nm).
LPD – Lighting Power Density is a calculation
derived by multiplying the number of fixtures
by input watts and dividing by the square footage of the space. This calculation is commonly
used in lighting system comparisons
LUMEN (LM) – Unit of measure for the flow
of light; expresses the total quantity of light
given off by a source regardless of direction.
Defined as the amount of light falling on a surface of one square foot, every point of which is
one foot away from one-candlepower sun.
LUMINAIRE – A complete lighting unit consisting of a lamp or lamps, along with the parts
designed to distribute the light, hold the lamps
and connect the lamps to a power source. Also
called a fixture.
LUMINAIRE EFFICIENCY – Light that
comes out of the fixture. See chart.
LTL – Luminaire Testing Laboratory. Lighting
manufacturers use this laboratory to conduct
photometric tests for luminaires.
MASTER/SATELLITE – Labor-saving, factory-installed wiring option in which ballasts
are shared by two luminaires to reduce installation labor. The master unit contains a ballast
M that provides power to some or all of the lamps
in the satellite unit. (Formerly Master/Slave).
MEDIUM BEAM – Light fixture with a
medium beam designed for aisles, open
industrial, or retail space usually mounted
from 22’ to 40’.
MERCURY VAPOR LAMP – A type of HID R
lamp in which the major portion of the light
is produced by radiation from mercury vapor.
Emits a blue-green cast of light. Available in
clear and phosphor-coated lamps.
METAL HALIDE – A type of HID lamp in which
the major portion of the light is produced by
radiation of metal halide and mercury vapors in
the arc tube. Available in clear and phosphorcoated lamps.
MOUNTING HEIGHT- The distance from the
bottom of the fixture to the floor.
MULTI-LEVEL SWITCHING – A system with
the ability to switch multi-lamp fixtures in such
a way as to provide two or more levels of light.
MULTI-TAP BALLAST – A ballast designed
to operate on more than one supply voltage.
NADIR – The point directly below the luminaire S
N (0Лљ angle)
NAED – National Association of Electrical
Distributors.
NAILD – National Association of Independent
Lighting Distributors, an organization supporting lighting distributors in the US with publica- T
tions, training, and conferences.
NARROW BEAM – Light fixture designed
to produce a narrow beam of light similar to
a spot light.
NEC – National Electrical Code. The document
compiled by the National Fire Protection Association to provide guidelines for installation
and application of electrical equipment.
NEMA – National Electrical Manufacturers
Association, the leading trade association in the
US representing the interests of electroindustry
manufacturers and providing a forum for
standardization of electrical equipment and
U
input into laws and regulations regarding
electrical products.
NEMRA – National Electrical Manufacturers
Representatives Association, an organization
promoting the use of independent manufacturers representatives as the most effective
method to market electrical products.
NLB – National Lighting Bureau, a nonprofit industry and government sponsored US
lighting information source, focusing on the
benefits of quality lighting.
OCCUPANCY SENSOR – A device that is
O preprogrammed to dim, shut off, or turn on V
a fixture or string of fixtures when a person
enters or leaves a designated area. Occupancy
Sensors can be designed to detect motion or
W
heat (IR).
ONE FOR ONE –Terminology used when retrofitting or replacing a lighting system utilizing
the same wiring and mounting location as the
existing system.
OPEN-CIRCUIT VOLTAGE – The voltage
applied across the output terminals of a ballast
when no load is connected.
PENDANT – A method of hanging luminaries.
P PHOTOCELL – A light-sensing device used
to control luminaires and dimmers in response
to detected light levels.
PHOTOMETRIC LAYOUT – A chart or
model of light levels generated by an array of
fixtures or lamps usually computer generated.
PHOTOMETRY – Numeric or graphic representation of light output of a light source.
PREHEAT – Refers to smaller fluorescent
lamps systems that use a “starter” to warm the
lamp electrodes, causing a delay before lamp
produces light.
PRISMATIC LENS – Lens with a pattern of
pyramid-shaped refracting prisms on one side
used to distribute the emitted light.
RAPID START – An instant on fluorescent
lighting system that does not use a starter.
Electronic ballasts may also feature programmed start for soft instant on in frequent
switching areas.
REFLECTOR – A piece of glass or metal,
usually concave, with a reflective surface that
directs radiant energy in a desired direction.
REFRACTOR – A translucent or transparent
“lens” or “diffuser” that changes the direction
of the light.
RESTRIKE TIME – The time required for a
lamp to start after a power interruption. Some
HID lamps need up to 11 minutes to restrike.
ROTARY LOCK LAMP HOLDER (Also
see SOCKET) – A common socket type for
European style T5 and T8 fixtures.
SOCKET – Electro-mechanical connection
in the fixture for the lamp.
SOCKET, MOGUL BASE – A 39 mm socket
commonly found in high wattage incandescent
and HID lamps.
STRIP FIXTURE – See CHANNEL.
T5 LAMP – Fluorescent lamps that are 5/8
of an inch in diameter.
T8 LAMP – Fluorescent lamps that are 8/8
or 1 inch in diameter.
T12 LAMP – Fluorescent lamps that are 12/8
or 1.5 inches in diameter.
TAMPERPROOF SCREW – A special screw
used to prevent vandalism.
TANDEM INLINE WIRING – Fixtures wired
together in pairs so they can share ballasts.
TROFFER – A long, recessed luminaire
usually installed with the opening flush with
the ceiling.
UNDERWRITERS LABORATORIES (UL)
INC. – An independent organization whose
responsibilities include rigorous testing of
electrical products. When products pass these
tests, they can be labeled (and advertised) as
“UL listed.” UL tests for product safety only.
ULTRAVIOLET (UV) – Radiant energy between
10 and 380 nanometers in wavelength, beyond
the violet end of the visible spectrum. Typically
used in ozone-producing light sources (120-220
nanometers), germicidal lamps (220-300
nanometers), and “black lights” (320-400
nanometers).
VANDAL RESISTANT – Fixtures made of
materials designed to withstand shock or
methods of vandalism.
WALLWASHER – A fixture used to illuminate
vertical surfaces from ceiling to floor.
WATT – The unit of power consumption or
use; one watt (w) is equal to one ampere of
current flowing through one ohm of resistance.
WET LOCATION FIXTURE – Fixtures designed
to come in direct contact with water.
WHIP – A prewired cable assembly attached
to the fixture to aid in installation.
WIDE BEAM – Light fixture designed to light
wide open areas, mounted 18’ to 30’
WIREGUARD – An assembly made of heavy
gauge wire to protect the housing or lamps
from breakage.
WORK PLANE – The level at which work is
done and at which illumination is specified
and measured.
Can’t find it…contact us…info@LumenOptix.com
11-0101
Industrial lighting Glossary continued