DEESYS TOTAL PRODUCTS GUIDE 디지털 전력보호 계전기기 Digital Power Protective Relay Venture Company KEPCO Venture Nuclear electrical Manufacturer’ s ISO9001 KSA9001 KSC 1303: Panel Meter KSC1706 : C.T/P.T Korea Fire Equipment Inspection Corp. Germanischer Lloyd TUV Product Service GMBH JIS C 1102 Korean Agency for Technology and Standards Digital Multi-Power Protective Relay Power Quality Meter Communication for Electrical protection System - Digital Protective Relay Digital Type Protective Relay Marine Type Protective Relay Digital Earth Leakage Detector and Relay Earth Leakage Ground Fault Relay Low Voltage Zero Phase Sequence Current Transformer Motor Protective Relay Induction Type Protective Relay Panel Board Meter Current and Voltage Transformer Insulator DEESYS TOTAL PRODUCTS GUIDE Digital Power Protective Relay Digital Multi-Power Protective Relay Power Quality Meter Communication for Electrical Protection System - Digital Protective Relay Digital Type Protective Relay Marine Type Protective Relay Digital Earth Leakage Detector and Relay Earth Leakage Ground Fault Relay Low Voltage Zero Phase Sequence Current Transformer Motor Protective Relay Induction Type Protective Relay Panel Board Meter Current and Voltage Transformer Insulator Digital Electric &Electronic system 인사말 Introduction 디이시스(주)는 전력보호계전기기 전문 생산업체로 D2K Series 라는 각종 Digital 계전기 및 집합형 누전경보기를 국내 최초로 개발 완료하여 특허출원을 완료하였습니다. 최근 전기 누전으로 인한 화재 및 인명, 재산의 피해를 사전에 예방하여 주는 소방법을 근거로 개발된 Digital 계전기 및 누전경보기 제품 은, 산업발전에 따라 전기 사용량이 증대되고 전력계통이 복잡 다양화 됨에 따라 전기로 인한 재해가 증가되고 있는 시점에 전력보호계전기기의 기능을 Up-grade하여 기기 한 대로 8회로에서 32회로까지의 다양한 모델을 선택함으로서 설치 면적을 최소화 하였으며, 기존의 기기와도 호환이 가능하여 개 보수 비용이 절감될 수 있는 획기적인 제품입니다. 기능, 설치, 운영면에서 보면, 현재 변전소의 무인화 및 원격 감시 시스템에 적용되고 있으며, 고기능 화 및 정보 전송의 간소화 등의 기술적 발전을 이룬 차세대형 배전감시 Digital 보호계전기기로서 최근의 수요, 공급의 확대로 많은 건축물의 전기사고로 인한 피해로 부터 인명, 재산을 보호하는 큰 역활을 담당하고 있습니다. History 연혁 79. 79. 82. 86. 88 91. 92. 3 7 6 9 10 4 5 대연전자 주식회사 창립 소방용 기계기구 제조허가 취득 제조업 허가 유망 중소기업 선정 한국 전기공업 협동조합 가입 한국 전기공업 진흥회 가입 계량기 제조업 허가 취득 한국 산업기술진흥회 가입 94. 1 계전기 말레이시아 및 동남아시아 수출 4 일본 Mitsubishi(주) 부품 공급계약 체결 10 김포공장 신축 준공-본사 및 공장 96. 3 기업부설연구소 설치 97. 3 복합형 전력용 변환기 개발 (한국전기연구소) 97. 12 DIGITAL 과전류 및 지락과전류 계전기 개발 99. 7 대한전기학회 특별회원 (대한전기학회) 00. 4 상호변경 대연전자(주)→디이시스(주) 01. 1 NPTC 한학연 회원사 5 변성기 공장 신축 02. 5 일본 KAWAMURA 전기(주) 수출공급 03. 4 대한전기협회 회원 가입 04. 4 대표이사 변경 (대표이사 유병국) 07. 2 디지털 계전기 개발 출시 Awards 수상실적 86. 92. 96. 97. 98. 98. 98. 99. 00. 00. 01. 02. 9 2 5 2 3 5 9 1 5 11 10 7 유망 중소기업 선정 신기술개발표창 품질관리대상수상 우수 수출업체 표창 조세의 날 표창 수출 및 신기술 개발표창 유망 VENTURE 기업 선정 기술경쟁력 우수기업 선정 유망 전력 VENTURE기업 선정 2000년 전기공업 수출부문 수상 2001년 전기공업 수상 수출 및 신제품 개발표창 제일은행 한국전기공업협동조합 한국소방검정공사 한국전기공업협동조합 경인지방국세청장 산업자원부장관 경기지방 중소기업청 중소기업청 한국전력공사 국무총리 산업자원부장관 행정자치부장관 Certificate 인증현황 80. 93. 95. 97. 98. 98. 99. 99. 00. 01. 02. 인증서 3 3 4 6 7 9 9 1 5 6 3 누전경보기(ELD, ELR) 형식승인 KS C 1303 지시전기계기인증 ISO 9002인증 ISO 9001인증 ELD, ELR 신제품 형식승인 원자력 (KEPIC-EN) 자격인증 KS C 1706 계기용 변성기 인증 GL선급협회 PFR인증 CE 인증(디지탈 계전기) 디지털 누전경보기 형식승인 JIS C 1102 지시전기계기인증 Certification 한국소방검정공사 한국표준협회 한국품질인증원 한국생산성본부 한국소방검정공사 대한전기협회 한국표준협회 GL선급협회(독일) TUV(독일) 한국소방검정공사 본공업규격 02. 5 EM우수품질인증 03. 11 CE 인증(디지탈 복합형계전기 EMC) 04. 3 CE 인증(디지탈 복합형계전기 안전 기술표준원 TUV(독일) TUV(독일) Digital Electric & Electronic system 디지털 전자화 배전반 종합보호 계전기 RS-232, 485 통신제어 Intelligent Elctronic Device[IED] 종합메터 MNET 종합보호계전기 MPRO 디지털 전력보호 계전기 (통신제어) Digital Power protective Relay 과전압 및 부족전압 계전기 OVR & UVR 디지털 누전경보기[ELD]/RS-485 통신제어 Digital Earth Leakage Relay 누전경보기 ELD 8회로 누전경보기 ELD 16, 24, 32회로 MICOM 누전경보기, 지락계전기 MICOM Type ELD, GFR 누전경보기 ELD 5, 10회로 지락계전기 GFR 5, 10회로 누전경보기, 지락계전기 Analog Type ELR, GFR 지락계전기(매입형)GFR 지락계전기(소켓형)GFR 누전경보기(매입형)ELR 디지털 전력보호 계전기 Digital Power Protective Relay 과전류 및 지락과전류 계전기 OCR & OCGR 재폐로 계전기 Reclosing Relay Digital Electric & Electronic system 유도형 전력보호계전기 Induction Protective Relay 과전류 계전기 OCR 부족전압 계전기 UVR 지시계기 메터 Panel Board Meter DIN 48, 72 각형메터 Square Type 상절체형 메터 각형메터(Square Type) 광각형 메터 Wide Type 모터 보호 계전기 Motor Protective Relay 4E 모터보호계전기 3E 모터보호계전기 디지털형 전력보호 계전기 Digital Type Power Protective Relay 과전류 및 지락과전류 계전기 OCR & OCGR 과전류 계전기 OCR 과/부족 전압 계전기 OVR & UVR 지락방향 계전기 DGR(SGR) 전력용 직류 / 교류 변환기 Power transducer 단품형 변환기 Single Type Transducer 변압기 및 변류기 (저압, 고압, 특고압) Epoxy Molded voltage & Current Transformer 영상 변류기 ZCT 저압변성기 Low Voltage CT,VT 고압변성기 High Voltage CT,VT 절연애자 (0.6kV~36kV) Insulator 안전을 위해 반드시 지켜야할 사항 본 제품을 사용함에 있어서, 아래 사항을 반드시 지켜 주시기 바랍니다. 또한 안전상의 주의가 필요한 사항에 대해서는 해당 제품의 취급설명서를 잘 읽어 주신 후 사용하여 주십시오. ■사용환경과 사용조건에 관한 사항사항 ■접속에 관한 사항 ●다음과 같은 장소에서 사용하지 말아 주십시오. ●단자 접속은 다음 사항을 지켜주시기 바랍니다. 오동작 및 수명이 단축될수 있습니다. �주위온도가 -10~60℃ 의 범위를 넘는 장소. 또한 안전을 위해 전기공사, 전기배선등의 전문기술을 가진 사람이 실행하십시오. �일평균 온도가 35℃를 넘는 장소. �습도가 30~70% RH의 범위를 넘는 장소. �먼지, 부식성가스, 염분, 연기가 많은 장소. �접속은 카다로그등의 접속그림과 같이 바르게 실행해주세요. ※부식성 가스는 아황산가스, 암모니아 가스, 유화수소가스 등 금속이나 플라 �부적절한 접속이나 공사는 제품의 파손 및 누전의 원이 됩니다. �접속에는 전기량과 단자크기에 따라 알맞는 입착단자를 사용하 스틱등을 부식시키는 가스를 말함. 십시오. �진동, 충격이 많은 경우. �단자BOLT는 적절한 공구에 의한 적합한 토크로 단단히 죄어 ※진동이 많은 장소에서 사용되는 경우 제품의 일부 부품이 공진이 발생되어 주세요. 소손될 우려가 있으며, 또한 오차나 기기변동이 발생할 경우가 있으므로, 방 진처리를 하거나 설치장소를 변경하시기 바랍니다. �비, 물, 자외선, 일광이 직접 닿는 장소. �노이즈 전파가 많은 장소, 정전기 발생이 많은 장소, 고조 파, 사이리스터회로 등의 파형왜곡이나 고조파가 많은 장소. ●다음의 설비에 사용되는 경우는 자사에 상담 하십시오. �원자력 프랜트, 의료장치, 군사설비, 비행기, 차량. M4나사 : 0.98~1.47N/m 주의 M5나사:1.47~1.96N/m �단자COVER는 안전을 위해 반드시 설치해주세요 �계기용변성기와의 접속은 2차측 극성에 유의하시기 바랍니다. �특히CT의 오접속 또는 CT 2차측의 개방은 고전압이 발생하여, CT의 고장 및 화재의 원인이 되며, 취급자들의 감전의 위험도 있습니다. �단자BOLT 에 윤활유 사용을 하지 마십시오. ■설치에 관한 사항 ●유통과정에서 과대한 충격등이 가해져 이상 상태가 되는 ■사용방법에 관한 사항 경우가 있으니, 외관등의 이상이 없는지를 확인해 주십시오. ●설치는 다음과 같은 사항을 지켜주시기 바랍니다. 또한 안 전을 위해 설치는 전문기술을 보유한 사람이 해 주십시오. �함에 제품을 설치할 때에 무리한 힘을 가해서 끼워넣거나, 제품이 스트레스를 받지 않도록 주의하시기 바랍니다. ●정격범위내에서 사용해 주세요 정격범위와의 사용은 오동작이나 고장의 원인이 됩니다. ※상세한 것은 카다로그 및 취급설명서를 참고 하십시오 ■고장시 수리 이상시 처리에 관한 사항 �또한, 볼트 및 너트를 이용하여 함에 설치할때에는 SIZE에 적합한 공구를 사용하여 단단히 죄어 주십시오. ※체결조임 토르크 M3 ; 0.48~0.98N/m M4 : 0.98~1.47N/m M5 : 1.47~1.96N/m �이상음, 이상발열 또는 고장이 생길 경우 즉시 입력차단 등의 응급조치를 행한후, 가장 가가운 대리점 및 본사 A/S 부서로 연락하시기 바랍니다. ■보수 점검에 관한 사항 ■ 보관에 관한 사항 ●제작을 오랜기간 바르게 사용하기 위해서는 일상점검을 하십시오 �제품에 손상이 없는가? �동작이나 지시에 이상(입력에 대응하지 않는 동작이나 지시) 이 없는가? �설치 또는 단자대의 결선에 느슨함이 없는가? ●장시간 보관하는 경우는 다음과 같은 장소를 피해주십시오. 고장 및 명단축의 원인이 될수 있습니다. �주의 온도가 -20~60℃의 범위를 넘는 장소. �일평균 온도가 35℃를 넘는 장소. �습도가 90% RH 이상으로 결로하는 장소. �먼지, 폐식성가스, 염분, 연기가 많은 장소. �진동, 충격이 많은 장소. �비, 수분, 자외선, 일광이 직접 닿는 장소. ※감전을 방지하기 위해서는 반드시 정전상태에서 행해주십시오. ●COVER는 대전방지처리를 했으므로 청결유지는 다음 사항을 지켜주세요.(특히 지시전기계기) �덮개표면의 더러운 것은 부드러운 헝겊으로 가볍게 두들겨 제거하십시오. 또, 심하게 더러울 경우는 교환을 하는 것이 좋습니다. ●관리는 전원을 끄고, 배선을 빼고, 비닐 봉투나 상자등에 넣 어서 보관하시기 바랍니다. ■ 폐기에 관한 사항 ●일반 산업용 폐기물로 처리해 주세요. �화학걸레등을 오랜기간 접촉시키거나 벤젠, 신나 등에 부식되지 않게 해주십 시오. 변형, 변색하거나 장식이 벗겨지는 등의 원인이 됩니다. �지시전기계기는 정전기에 의한 지침이 불안정한 동작을 하는 경우가 있습니다. 그 경우는 시판되 는 대전 방지제를 COVER에 도포하여 주십시오. ●절연시험에서 제품에 파손되는 경우가 있으므로 다음 사항을 지켜주시기 바랍니다. �전압 시험 시의 인가 전압은 기종및 단자에 따라 다르므로 카다로그에 기재된 전압을 지켜주십시오. �인가개소에 주의하십시오. VT입력 단자간의 동일전위에 인 가하면 고장의 원인이 됩니다. ●사용할 때에는 제품이 정상동작을 하는가를 확인하십시오. �제품의 수명은 사용상태에 따라 틀리지만 대략 10년을 추정 하고 있습니다. Contents Digital Multi-Power Protective Relay Motor Protective Relay ■D2K-MPRO Digital Multi-Power Protective Relay 2 ■Motor Protective Relay ■3E, 4E Motor Protective Relay 14 Power Transducer Power Quality Meter ■D2K-MNET Quality Power Meter Communication for Electrical Protection System- Digital Protective Relay ■3 Phase Digital Over Current and Earth Fault Relay [50/51, 50N/51N] 20 Digital Protective Relay ■Reclosing Relay [79] 32 Digital Type Protective Relay ■Digital Over Current and Earth Fault Relay [50/51x3, 50/51N] ■Digital Over and Under Voltage Relay [59/27]3∅ ■Multi Function Over Current and Earth Fault Relay [50/51x3, 50/51N] ■Over Current Relay [50/51x2] [50/51x3] ■Ground Over Current Relay(Earth Fault Relay) [50/51N] ■Multi Function Over and Under Voltage Relay [59/27] ■Over and Under Voltage Relay [59/27]1∅ ■Ground Over Voltage Relay [64] ■Directional Ground Relay [67] ■High Voltage Zero-Phase Current Transformer [ZCT]HZR-Series ■Static Phase Open Relay [47] ■High Voltage Ground Relay [51G] 36 42 50 57 63 67 73 77 81 84 85 88 Marine Type Protective Relay ■선박용 ■선박용 ■선박용 ■선박용 ■선박용 3 Phase Voltage and Frequency Relay 3 Phase Phase Fail Relay 3 Phase Phase Sequence Indicator Relay Single or 3Phase Synchroscope Dimension 96 97 98 99 100 Digital Earth Leakage Detactor and Relay ■D2K-ED Series Earth Leakage Detector and Relay 102 Earth Leakage Ground Fault Relay ■Multi Function Earth Leakage Detector and Fire Alarm ■Earth Leakage Fire Alarm and Relay [ELR] 1C, 5C, 10C ■Earth Leakage Relay [ELR] 1C ■Multi Function Ground Relay [GFR] 5C, 10C ■Aux Relay Board [Isolation] 5C, 10C ■Ground Fault Relay 1C 112 122 124 125 132 133 Low Voltage Zero Phase Sequence Current Transformer ■Zero Phase Sequence Current Transformer [ZR, ZS, ZB, SZR-Series] ■Zero Phase Sequence Current Transformer [ZB-Series] ■Cable & Busbar Through Type [ZR, ZS, ZB, SZR-Series] ■Busbar Mold Type Zero Phase Sequence Current Transformer [3∅ 3W] ■Busbar Mold Type Zero Phase Sequence Current Transformer [3∅ 4W] ■How to Installation and Inspection 138 140 141 142 143 144 ■Power Transducer ■Voltage Transducer ■Current Transducer ■Watt Transducer ■Var Transducer ■Watt/Watt Hour Transducer ■Var/Var Hour Transducer ■Power Factor/Phase Angle Transducer ■Frequency Transducer ■Analog to Pulse Transducer ■Zero Sequence Voltage Transducer(V0) ■DC mV/DC V Transduce ■Isolator/Temperature Transducer 146 151 162 163 165 167 171 173 175 177 179 181 182 183 184 Induction Type Protective Relay ■Induction Protective Relay ■Induction Type Over Current Relay [OCR] 50/51 ■Induction Type Ground Over Current Relay [50N/51N] ■Induction Type Over, Under Voltage Relay [59] [27] [64] ■Induction Type Directional(Selective) Ground Relay [67] ■How to Drawout ■Dimension 186 188 193 195 198 200 201 Panel Board Meter ■Panel Board Meter ■Panel Board Meter [DIN Type] ■Panel Board Amper Meter ■Panel Board Volt Meter ■Panel Board Watt Meter ■Panel Board Var Meter ■Panel Board Factor Meter [cosφ ] ■Panel Board Frequency Meter [Vo] ■Panel Board Maximum Demand Meter [Vo] ■Panel Board Maximum Demand Meter [Ao] ■Panel Board Meter Dimension ■3상 절환형 각형 지시전기계기 [교류전압전류계] ■Digital Panel Board Meter 204 206 207 208 209 211 214 216 217 218 219 221 223 Current and Voltage Transformer ■Round Type Current Transformer [1.15kV] ■Winding Type Current Transformer [1.15kV] ■Square Type Current Transformer [1.15kV] Busbar 취부용 ■Square Type Current Transformer [1.15kV] Panel 취부용 ■Voltage Type Transformer [0.72kV] ■Busbar Type Current Transformer [3.45-7.2kV] ■Square Window Type Current Transformer [3.45-7.2kV] ■Voltaget Transformer [3.45-7.2kV] ■Ground Type Voltage Transformer [3.45-7.2kV] ■Round Type Zero Phase Current Transformer [3.45-7.2kV] ■Epoxy Resin Insulator [0.6kV] ■Epoxy Resin Insulator [7.2, 12kV] ■Epoxy Resin Insulator [24kV] ■Epoxy Resin Insulator [24, 36kV] ■Shunt [Voltage Drop 50mV] ■Current Limit Resister [CLR] 230 232 233 234 235 236 237 238 239 240 241 243 246 247 248 249 한국전기연구원 개발시험합격품 D2K-MPRO Digital Multi-Power Protective Relay ■ Intelligent Electronic Device [OCR 50/51, OCGR(50/51N), UVR(21), OVR(59) OVGR(64G), SGR(67G), DOCR/DOCGR(67N)] D2K-MPRO 전자화 배전반 종합 보호 계전기 D2K-MPRO Digital Multi-Power Protective Relay MODEL D2K-MPRO 특징 Features MPRO는 고신뢰성의 디지털 보호계전기능, 정밀한 계측기능 및 차단 기 제어기능을 수행하고, 중앙감시시스템과의 다양한 인터페이스를 통 한 원방감시제어가 가능하며 고기능의 전자식 배전반 Solution을 가능 하게 하는 IED(Intelligent Electronic Device)입니다. 또한 직접접지 또는 비접지 계통에서도 적용되며 중소용량의 발전소가 연계된 계통에 서 방향성(Directional OCR) 선택/동작시도 적용할 수 있습니다. MPRO is a IED(Inteligent Electronic Device) that provides a solution for high reliable multi purpose digital protective relay, precise measurement and circuit breaker controls, remote controls interfacing with a central detective system, and a high performance distributing board. This works with or without grounding, or directional OCR in a small power plant. Specificatain 50/60(Hz) 사용주파수 정격 전류 CT 5(A) ZCT(1차/2차) 200/1.5(mA) PT 100(V) GPT 190(V) CB 제어용 30(A) 250VAC, 0.5sec 신호용 5(A) 250VAC 정격 전압 정 격 사용온도및 습도 출력접점 상 태입력 AC/DC 110~250(V) 2.5VA 이하 제어전원 AC/DC 86~250(V) 사용 온도 습 사용온도 -20~60℃ 보관온도 -25~70℃ 일평균30~80% 도 절연 저항 IEC60255-5규격 적용 상용주파 내전압 뇌 임펄스 내전압 IEC60255-6규격 적용 과부하 내량 1MHz Burst 내환경 성능 Electrostatic Discharge EMC Fast Transient IEC60255-22, IEC61000-4 규격 적용 Sureg RF Interface 2 DEESYS TOTAL PRODUCTS GUIDE EMI IEC60255-22-3규격 적용 진동 및 충격 EC60255-22-3규격 적용 D2K-MPRO Digital Multi-Power Protective Relay 특징 Features ● 다기능 디지털보호 계전기능 OCR, DOCR(Option), OCGR, UVR, OVR, OVGR, DOCGR(Option), SGR ● Multi purpose digital protective relay OCR, DO(Option), OCGR, UVR, DOCGR(Option), SGR ● 정밀급(1.0급)의 각종 전기량 계측기능 - 전류, 전압, 유 . 무효전력, 유 . 무효전력량, 역률 및 주파수 - 각 계측 데이터별 Pick Demand - 시간대별 각종 Demand의 3개월간 데이터를 저장 관리하는 Load Profile 기능 ● Precision voltammeter: - current, voltage, effective, reactive power, power factor, and frequency - pick demand on each measured data - load profile function that store data in time for 3 months ● 다양한 표준 통신 Protocol 수용 (별도의 Protocol 변환기 불필요) 주문시 선택 - DNP 3.0 - ModBus - IEC 60870-5 - LonWorks - BACnet ● compatible with various standard communication Protocol ● 고장정보 기록기능 - 최근 32개의 고장정보 저장. 관리기능 - 최근 4개의 고장파형 저장. 관리기능 ● Store system error - store 32 errors from the most recent data - store 4 frequency errors from the most recent data ● 사용자 인터페이스 터미널 포트를 통하여 각종 설정 및 계측데이터, 보호 특성커브, 고장파형 등을 확인 ● User interface - Able to check the setting, measured data, protective curve, and frequency error by communication port. ● 다양한 제어전원 Free Voltage : AC/DC86~250[V] Option : DC24/48[V] ● Various control - free voltage: AC/DC 86~250V - option: DC 24/48 V ● 전원 상실 시 - Time-Keeping 기능 - Event 기록 및 로그 정보유지 ● Power off - save time function - save log information and event ● 구조 - 인출형 [Drow out type] ● Type - draw out OVR, OVGR, (protocol converters are optional) - DNP 3.0 - ModBus - IEC60870-5 - LonWorks - BACnet Front plate Display Panel - High quality LED - 20 characters with 4 lines Relay Operation - Display operation relay LED - Pick up status LED - Reset button Operation status - Run - System fail System reset button Local/Remote mode - LED or button User interface(Terminal Port) - RS-232C - Optical port(option) Communication status - display communication status with mater (refer to the back) - Tx(green)/Rx(red) User function key - measured data display - relay setting - communication parameter setting - event setting - addition function setting Power On/Off button - On(red) - Off(green) DEESYS TOTAL PRODUCTS GUIDE 3 D2K-MPRO Digital Multi-Power Protective Relay Operating Characteristic Curve 한시 동작 특성(Time delay characteristics IEC-60255) � I -1K �+ C × T= a tp 10 a K C 반한시 Normal Inverse(NI) 0.02 0.14 0 강반한시 Very Inverse(VI) 1 13.5 0 초반한시E xtreme Inverse(EI) 2 80 0 I: 과전류에 대한 배율(%) tp: 동작시간(Lever) 정한시 동작 특성 Definite time operation T = tp (0.1~10sec) Specificatain 계전기능 동작구분 순시 동착치 동작시간 설정범위 설정단위(Step) 설정범위(Lever) 5~80A, Block � 1 A� 40ms 이하 설정단위(Step) OCR (50/51) 특성 반한시, 강반한시 한시 0.2~16A. OFF 0.1 �A� 0.2~50.0 0.2 초반한시 *정한시 순시 3~40A. OFF 0.5 �A� 40ms 이하 한시 0.2~5A. OFF 0.1 �A� 0.1~50.0 순시 반한시, 강반한시 OCGR (50/51N) 0.2 초반한시 *정한시 순시 5~80A. OFF � 1 A� 40ms 이하 한시 0.2~16A. OFF 0.1 �A� 0.2~50.0 순시 반한시, 강반한시 DOCR 동작위상각 한시 0~90(1。 단위 설정) ±60~±90(1。 단위 설정) (0.1~1)×110 �V� 1.0 �%� 0.2~50.0 0.2 반한시, 정한시 OVR(59) 한시 (1.1~1.4)×110 �V� 1.0 �%� 0.2~50.0 0.2 반한시, 정한시 OVGR(64) 한시 (0.05~0.4)×190 �V� 1.0 �%� 0.2~50.0 0.2 반한시, 정한시 전류 1~10 �mA� 0.1 �mA� SGR 전압 (0.05~0.4)×190 �V� 1.0 �%� 0.2~50.0 0.2 정한시 (67G) 기준위상각 0~90(1。 단위 설정) 동작위상각 ±60~90(1。 단위 설정) 0.2 초반한시 *정한시 순시 3~40A. OFF DOCGR 한시 (67N) 기준위상각 0~90(1。 단위 설정) 0.2~5A. OFF 동작위상각 ±60~90(1。 단위 설정) *정한시 설정은 공통으로 0.1sec~10sec(0.2sec step)임 4 초반한시 *정한시 기준위상각 UVR(27) 0.2 DEESYS TOTAL PRODUCTS GUIDE 0.5 �A� 0.1 �A� 40ms 이하 0.1~50.0 반한시, 강반한시 D2K-MPRO Digital Multi-Power Protective Relay Characteristic Curves 반한시 보호특성(Normal Inverse) 강반한시 보호특성(Very Inverse)) 초반한시 보호특성(Extremely Inverse) 정한시 보호특성(Definite Time) DEESYS TOTAL PRODUCTS GUIDE 5 D2K-MPRO Digital Multi-Power Protective Relay Control 상태입력 Optional Analog입력 제어출력 Event 관리 입력구성 Photo-Isolated Binary Input Remote Fault Reset 1 Port CB Remote ON/OFF 2 Port Programmable Contact 3 Port (DI) 입력회로 AC220V/DC250V,AC110V/DC125V �4~20[mA] 아날로그 입력 �전기적 절연으로 외부 Surge에 안전한 구조 �온도 및 가스압력 등의 감시를 위한 별도의 RTU불필요 출력단자 용량 비고 TRIP(1Port) 30A/250VAC(0.5sec) *Programmable CB ON/OFF(2Port) 30A/250VAC(0.5sec) Contact Output 경보용(6Port) 5A/250VAC (설정에 따라 재구성 가능) �1ms SOE처리 �전원 상실시에도 데이터 백업유지 �차단기 ON/OFF(현장/원방 구분)제어 �설정치 변경(현장/원방 구분) �현장/원방 선택변경 �IED Restart (Power On/Watchdog Restart구분) �자기진단에 의한 시스템 Failure �Binary Input Change �사고발생 및 Fault Reset Communication 다양한 표준 Protocol을 탑재, 유연한 감시 시스템 구성 가능 (감시반 구성을 위한 별도의 Protocol 변환 장치 불필요) 통신 Port 전력 감시시스템 구성예 ∙Port 1 : RS-232C ∙Port 2 : Isolated RS-485 통신 Protocol ∙DNP3.0 ∙ModBus ∙IEC60870-5 ∙LonWorks ∙BACnet - 통신채널당 최대 64대의 IED 접속가능 - 통신거리 최대 1.2km(RS-485 구성시) 6 DEESYS TOTAL PRODUCTS GUIDE Eather-net (TCP/IP) D2K-MPRO Digital Multi-Power Protective Relay Metering 계측사양 표 시 오 차 3상 전류(A) 0~10,000(A) ±0.5% 3상전압(V) 0~200,000(V) ±0.5% 영상 전압(V0) 0~10,000(A) ±1.0% 영상 전류(I0) 0~200,000(V) ±1.0% 유효 전력(WATT) 0~9,999(MW) ±0.5% 무효 전력(var) 0~9,999(Mvar) ±0.5% 유효 전력량(W/H) 0~999,999(MWH ±1.0% 무효 전력량(var/H) 0~999,999(MvarH) ±1.0% 역률(P.F) Lead/Lag 0~100(%) ±0.1% 주파수(Hz) 45.0~65.0(Hz) ±0.01Hz 비 고 선간 전압 및 상전압 Load Profile 항목 Pick Demand 관리 전기량 전류, 전압 기록용량 월간 Pick 발생 시각 및 Pick 값 유효전력, 무효전력 유효전력량, 무효전력량 역률 주파수 시간대별 Demand 최근 3개월 Data 유효전력, 무효전력 유효전력량, 무효전력량 역률 주파수 Fault Memory 운전정보기록 ∙IED 운전관련 종합이력정보 저장 . 관리 ∙실시간 SOE처리 기능 (1ms 해상도) ∙Event 정보 Back Up (최대 128개) ∙Fault 정보(최대 128개) 항목 고장 정보 관리데이터 고장시 3상 전류, 전압 및 영상전압의 크기 및 위상각 기록용량 최근 128개 고장 데이터 고장 발생 시각 고장 상 표시 동작 계전기 및 형태 표시 총 고장 횟수 고장 파형 데이터 고장 발생 시각 최근 고장 파형 4회 각 상전류, 전압 파형 (128Cycle 샘플 데이터/1회) 영상전류, 영상전압 파형 DEESYS TOTAL PRODUCTS GUIDE 7 D2K-MPRO Digital Multi-Power Protective Relay Menu Specification Front Panel에는 LCD와 LED 및 Function Key에 의해고장 상태 표시, 설정치 변경 및 표시, IED 동작이상 및 통신상태, 각종 계측량 Fault Reset등을 수행 할 수 있습니다. 또한 별도의 터미널 포트를 구비하여 편리한 User Interface 기능을 수행할 수 있으며 보호 특성 커브나 고장 파형을 확인 할 수 있으며 모든 Data는 PC에 저장하여 사후 분석할 수 있습니다. 표준 RS-232C 사용 통신속도 : 9,600 - 38,400bps 설정가능 Terminal Port를 이용한 User용 Local Interface구성 ● 계측치 / DI 상태표시 ● 차단기 상태표시 ● Polling주기 조절에 의한 자동 갱신기능 ● 에러 및 통신상황 표시 ● 통신 Transaction View 8 DEESYS TOTAL PRODUCTS GUIDE D2K-MPRO Digital Multi-Power Protective Relay ● ● ● ● 설정 입력 동작 동작 계전기 동작 특성 확인 신호에 따른 동작시간 계산확인 시간 배수 변경 특성 변경 ● 계전요소별 설정값 표시 ● 설정치 자동 갱신 ● 설정치 변경 화면 활성 ● 계전요소별 설정값 변경 기능 ● 기본 설정값 복원 기능 ● 설정 최대 및 최소값 준수 DEESYS TOTAL PRODUCTS GUIDE 9 D2K-MPRO Digital Multi-Power Protective Relay Menu Specification ● 최근 고장의 상세 정보 표시 ● 실시간 자동 갱신 기능 ● 고장파형 선택 ● 파형 읽기/삭제 ● 고장파형 파일 저장 기능 ● ● ● ● ● ● ● 10 고장파형 분석 고장정보 표시 영역별 탐색/확대 기능 파형별 컬러 지정 파형 복합 기능 채널 선택 기능 2개 이상의 파형 비교 기능 DEESYS TOTAL PRODUCTS GUIDE D2K-MPRO Digital Multi-Power Protective Relay Wiring EXternal Wiring(3P4W) EXternal Wiring(3P3W) ● UVR ACTIVE로 설정할 경우 P.T 전압이 없으면 TRIP접점이 항상 출력되고 있습니다. ● UVR이 동작하고 있으면 CB제어가 안됩니다. DEESYS TOTAL PRODUCTS GUIDE 11 D2K-MPRO Digital Multi-Power Protective Relay Dimension Front View Side View Cutting View Rear View 12 DEESYS TOTAL PRODUCTS GUIDE 한국전기연구원 개발시험합격품 D2K-MNET Power Quality Meter ■D2K-MNET Power Quality Meter D2K-MNET 원격 감시제어용 종합메터 D2K-MNET Power Quality Meter Introduction D2K MNET D2K MNET은 전형적인 Power Meter를 뛰어넘어 혁신적으로 디자인 되었으며, 컨셉화 되어졌습니다. 또한 D2K MNET은 작아지고, 전자적으로 진보했으며, 프로그램이 가능한 종합 측정 장비입니다. D2K MNETⅢ는 미래의 전기적 측정방법의 여러가지 요구에 대한 해답이 될 것입니다. D2K MNET의 Concept은 몇가지 아래와 같은 원칙을 기본으로 디자인 되었습니다. Environmental Impact & Cost Saving D2K MNET은 많은 아날로그 혹은 디지털 장비를 대체할 수 있고, 그에 필요한 배선 및 컨트롤스위치를 줄임으로서 많은 비용을 절감 할 수 있으 며, 컨트롤 판넬외 전면부를 간소화 시킬수 있습니다. Increase Productivity &Efficency D2K MNET은 설치시 발생하는 많은 케이블과 작업시간을 대폭적으로 줄일 수 있으며, 1p2w/1p3w/3p3w/3p4w 결선을 사용할 수 있습니다. Improved Tecnical Superiority and Reliablity D2K MNET은 기존 장비보다 훨씬 앞선 기술적 능력을 갖고 있습니다.(Overload capabilities, accuracy levels, long term stability, readout dependability, etc) D2K MNET은 전면 표시창의 VFD(Vacuum Fluorescent Display) 사용으로 기존의 녹색 표시장치에서 발생되었던 원거리 에서 읽기 어려웠던 문제점을 극복하였으며, 안개와 같은 악조건 속에서도 표시창을 통하여 30가지가 넘는 정보를 순차적으로 자동 스크롤 혹은 수동 스크롤 기능을 통하여 읽어들일 수 있습니다. 또한, 범용 Modbus� protocol의 RS232/485 통신 포트를 내장하여 PC를 통해 각종 정보를 읽어들일 수 있으며 장치를 관리할 수 있습니다. Parameters Conversion Microprocessor가 내장된 D2K MNET은 modicon사의 Modbus� 시스텀을 기본으로 제공합니다. 이는 제품의 정보 표시창으로부터 읽어들일 수 있는 30가지 이상의 정보보다 더 많은 90가지 이상의 정보를 PC를 통하여 감시 제어 할 수 있는 기능을 제공합니다. Features ● 90가지 이상의 전력 및 에너지 정보표시 ● 공장과 건물의 자동화 ● Modbus protocol 탑재 ● 최대 600V 사용가능 ● True RMS 변화가능 ● 순시 최대값, 최소값 표시기능 ● 선명하고 긴 수명의 VFD채용 ● RTC 내장(Real Time Clock) ● P.T / C.T 비율 설정가능 ■ ■ ■ ■ ■ ■ ■ ■ ■ ● Factory & Building Automation (FA & BA) D2K MNET은 AC Switch-gear 혹은 공장 전력분배 시스템에 광 범위하고 쉽게 적용이 가능하여 공장과 건물의 자동화로의 발전을 도와줍니다. ● Memory for all setup and energy data 전원공급이 중단되어도 D2K MNET은 측정된 Wall-Hopur, 최대 수요전력, 날짜와 시간, PT/CT비, 시스템설정값, 표시설정값, 통신 관련 데이터등의 모든 값을 메모리에 저장하여 안전하게 보관합니 다. ● PLC Modbus Compatible Modbus communications protocol 은 D2K MNET과 Programmable Logic Controller(PLC) 혹은 다른 thirdparty 의 Modbus 호환 모니터링 프로그램, 컨트롤 시스템간의 데이터를 효 율적으로 변환합니다. 또한 IPC-based centralized master display software 를 쉽게 채용할 수 있는 모니터링 시스템을 채용 하였습니다. ● Built-in Real Time Clock D2K MNET은 실시간 타이머(Real Time Clock)를 내장하여 최대/ 최소 에너지값을 기록할 수 있으며, 수요전력 Sampling(Display) Time을 설정 할 수 있습니다. (15/30Minute) 14 DEESYS TOTAL PRODUCTS GUIDE 0.15% 이내의 오차 최대 수요전력의 통제 모든 셋팅값과 데이터의 저장 광범위한 Selftest Low input burden 0.1VA (5A /120V) 폭넓은 제어전원 사용 (80~260V AC/DC) 간략화된 제품의 구성 DIN & ANSI 에 적합한 Cutout 2kV RMS input / output / power 의 절연 ● Field Programmability D2K MNET은 CT/PT비, Modbus @ address, 통신속도, parity, display등을 전면의 버튼을 이용하거나 통신포트를 이용하여 PC에 서 현장의 조건에 맞도록 설정이 가능합니다. ● Accuracy up to 0.15% 더욱 발전된 conversion,“ sampling 그리고 software 보상기술 로 전압과 전류는 0.15% 이하, 전력은 0.25%이하의 오차율을 실현 하였습니다. PC를 통하여 감시 제어할 수 있는 기능을 제공합니다. D2K-MNET Power Quality Meter Model & Ordering Number Model : D2K MNET -5.0A DMM - H - 1 - 1 Current Input 1.0A 5.0A Wiring 1 : 1P2W 2 : 1P3W 3 : 3P3W 4: 3P4W Power H: AC 80-260V, DC 80-330V L: DC 20-60V Communcation Port 1: RS-485 2: RS-232 Specification Programmable measurements / Accuracy / Display readouts Param. Digits Accuracy Phase1 Phase2 Phase3 Vx3 5 (or 4) 9.9.9.9.9. V / KV Display(maximum) 0.15% fs V1 V2 V3 Ax3 5 (or 4) 9.9.9.9.9. A / KA 0.15% fs A1 A2 A3 Watts 5 (or 4) 9.9.9.9.9. W / KW / MW / GW 0.25% fs W1 W2 W3 Vars 5 (or 4) 9.9.9.9.9. Var / KVar / MVar / GVar 0.25% fs Var1 Var2 Var3 Var VA 5 (or 4) 9.9.9.9.9. VA / KVA / MVA / GVA 0.25% fs VA1 VA2 VA3 VAE PF 4 0.9999 0.25% fs PF1 PF2 PF3 WH 8 9.9.9.9.9.9.9.9.9. WH / KWH /MWH 0.8% rd WH VarH VarH 8 9.9.9.9.9.9.9.9.9. VarH / KVarH / MVarH 1% rd IO 5 (or 4) 9.9.9.9.9. A / KA 0.5% fs Hz 5 (or 4) 70.000 0.03% rd ● Accuracy : Corresponding to each auto-range scale ● VL1 / VL2 / VL3 : Line to line voltage VP1 / VP2 / VP3 : Line to neutral voltage ● PF1 / PF2 / PF3 : Related conversion elements ● IO (neutral current, only for 3 phase 4 wires) Total Average VE AE W PF ● Accuracy performance range for WH / VarH / PF Cos Θ : 1-0.5 for WH / PF Sin Θ : 1-0.5 for VarH Voltage � 75V, Current � 0.5A ● Phase rotation SEQ POST : positive sequence SEQ NEG : negative sequence DEESYS TOTAL PRODUCTS GUIDE 15 D2K-MNET Power Quality Meter input ● Range Voltage : 10 - 600V Current : suitable for CT secondary rating(optional) Maximum 6A for 5A rating Maximum 1.2A for 1A rating Frequency 40 -70 Hz ● Burden Voltage < 0.4VA at 600V < 0.04VA at 150V Current < 0.1VA at 5A Overload rating Current 2 X rated continuous 10 X rated 30 seconds 25 X rated 2 seconds 50 X rated 1 sceonds voltage 750V continuous 1000V 10 seconds 1200V 3 seconds Measured system ● Suitable for 3 phase 4 wires / 3 phase 3 wires/ single phase 2 & 3 wires / 3 phase balance ● Select by input wiring & software configuration Programmability ● Software accessible / password lock ● System selection : 3 phase 4 wires/ 3 phase 3 wires / 1 phase 2 & 3 wires / 3 phase balance ● PT: 1 - 5000.0 ; CT : 1 - 2000.0 ● Readout display control 5 or 4 digit / auto scan or manual selection / scanning time ● Maximum demand 1 - 60 min ● Maximum and minimum of instant measurement ● Communication baud rate 1200/ 2400/ 4800/ 9600/ 19200 parity (even or odd) / None Address setting 1 -254 ● Calibration software with password lock ● Memory all of energy date and status setting 16 DEESYS TOTAL PRODUCTS GUIDE Communication port RS485 ( standard) : RS232 (option) Moobus RTUprotocol Display VFD / 0.28”/ blue color, 3 rows of 9 alphanumerics RTC Maximun deviation 5 sec in 24 hours Time for year / month / date / hour/ minute / sec Dielectric strength IEC 255-5 2KV AC rms 1 minute between input / output /power Impulse and surge test ANSI / IEEE C37.90.1-1989(3KV) SWC test IEC 255-22-1 class III SWC test IEC 255-22-4 class Ⅳ (IEC 801-4) SWC test IEC 255-5 1.2 50us (5KV) impulse test Stability Temperature range - 24 to +55 ?C Maximum 100 ppm / ?C Long term stability 0.15% drift maximum per year Operation condition Temperature range - 25 to + 60 ?C, RH 20 - 95% non-condensed Power supply AC 80-260V, 40-70 Hz, DC 80 - 330V DC 20-60v (option) Dissipation maximum 12VA for AC and 6 watts for DC D2K-MNET Power Quality Meter Applications The D2K-MNET PC TOOL a utility program that can help user to connect to“D2K-MNET Power Meter”rapidly. The D2K-MNET PC TOOL, provided with every D2K-MNET meter , allows easy access to all meter setup information and actual values via a personal computer running Windows 95/98 and one of the PC’s communication ports-COM1 or COM2. The user can: ● ● ● ● Program/ Modity setup information Load/save setup information files from/to disk Read actual“Basic”value (current/voltage/power/frequency) Read actual“statistics”value (maximum/minimum/time of maximum/time of minimum) The “D2K-MNET PC TOOL”can be used“stand-alone” , without a D2K-MNET meter, to create or edit D2K-MNET meter setup information files. SCADA System RTU DCS System HC 6000 PC Tool PLC Test set RS-485 ModBus Communication Bus (RTU Mode) Communication Wiring Computer RS485 D- D+ Up to 32 devices, maximum 4000 feet Ground shield at SCADA/ PLC/Computer only (one end grounding) Shield Twisted pair Shielded cable ZT(*) R = 120 ohm C C = 1000pF R Com D- D+ Com D- D+ Com D- D+ METER METER METER DEESYS TOTAL PRODUCTS GUIDE 17 D2K-MNET Power Quality Meter Wiring 3 Phase 3 Wires Unbalance Load AS AL BS BL CS CL PA PB 1 Phase 2 Wires / 3 Phase 4 Wire balance Load PC PN FG Power AS AL BS BL CS CL PA PB PC PN FG _ +~ - _ +~ - L1 L1 L2 L2 L3 Source Load Source BL CS CL PA PB PC PN Load 3 Phase 3 Wires Unbalance Load (3CT) 3 Phase 4 Wires Unbalance Load AS AL BS FG Power AS AL BS BL CS CL PA PB PC PN FG _ +~ L1 L2 L3 N BL CS CL PA PB PC PN Source Load �Setting system : 3 phase 4 wires Load 3 Phase 3 Wires Unbalance Load (3CT) 3 Phase 3 Wires Balance Load (1) AS AL BS FG AS AL Power BS BL CS CL PA PB PC PN FG L1 L2 L3 L1 L2 Source Source Load AS AL BS BL CS CL PA PB PC PN FG Power _ +~ - 18 Standard RS485 L1 L2 Load Source DEESYS TOTAL PRODUCTS GUIDE Load Communication Port 3 Phase 3 Wires Unbalance Load L3 Power _ +~ - _ +~ - L3 Power _ +~ L1 L2 L3 Source Power Option D+ D- Com X Y Z RS232 RxD TxD SG X Y Z 한국전기연구원 개발시험합격품 Communication for Electrical Protection system -Digital Protective Relay ■3 Phase Digital Over Current and Earth Fault Relay [50/51, 50N/51N] D2K-OG50 과전류 & 지락과전류계전기 D2K-OG50 Series 3-Phase Over Current and Earth Relay[50/51,50/51N] MODEL D2K-MOG50 System and Protection 디지털 과전류 계전기는 32bit DSP(Digital Signal Processor)를 내장 하고 1Cycle을 24Sampling 하며 A/D Converter로 변환, Sampling 값을 연산 처리한 고속 Digital Relay 입니다. Apply 이 계전기는 154kV 또는 22.9kV 직접 접지 또는 저항 접지 계통에 사 용 할 수 있으며, 다기능 다특성을 내장하고 있어 설계 초기에 계전기 선택이 용이합니다. 특히 장강반한시(LT-VI)특성을 추가하여 강반한시 특성의 상위 Lever를 확대했으며, 동작특성 Lever도 정정가능 범위를 세분화 확대하였습니다. Features Display Mode 각 상의 현재 상태전류를 기준으로 하여 A, B, C, N상의 전류상태 를 실시간으로 LCD(Liquid Cristal Display)표시창에 표시합니다. Keypad and Communication 모든 정정치 및 Data는 전면부의 Keypad 또는 RS 232 Port로 PC 와 연결하여 Control 할수 있으며, 후면의 RS485 Port를 이용하여 중앙 Control system에서도 릴레이의 모든 기능을 점검 할 수 있 습니다. Fault Memory [Memory view] 사고 Data의 횟수는 10회까지 Memory한다. ∙Fault current ∙Fault time ∙Fault phase ∙Fault date ∙Fault type 20 DEESYS TOTAL PRODUCTS GUIDE Monitoring and Protocol 사고파형을 저장함으로서 Event Monitoring이 실시간 가능합니다. Digital Relay는 Setting Range가 광범위하여 어떠한 상황에서도 정정이 가능하고, 자동화 설비를 위하여 DNP3.0 또는 호환 및 신 뢰성이 높은 Modbus 프로토콜을 적용 하였으며 수용가 요구시 제 공됩니다. 이 계전기는 수용가의 목적에 따라 기능 및 정정 범위를 변경하여 공급 할 수도 있습니다. Fault Event Monitoring Fault Event 파형을 72Cycle까지 저장 할 수 있어 사고 분석을 용 이하게 하고 특히 무인화 시스템에 적용됩니다. D2K-OG50 Series 3-Phase Over Current and Earth Relay[50/51,50/51N] Typical substation architecture Eather-net (TCP/IP) Communication for Specification 통신사양 통신속도(Comm Speed) : 19,200bps 통신거리(Comm Length) : 1.2km 통신방식(Comm Port) : RS232/485 최대노드수(Max. node) : 64Set Read Write �Current display(pr.se) �Setting position �Fault current(se) �Fault time �Fault phase �System state check �Date and time �Current set �Time Lever set �CT ratio(pri/sed)set �Frequency set �Operatung curve set �Communication set DEESYS TOTAL PRODUCTS GUIDE 21 D2K-OG50 Series 3-Phase Over Current and Earth Relay[50/51,50/51N] Specification Model ▶D2K-OG50 Part Name Model Standard code Element Aux. power Rating OCEF Three Phase - Over Current and Earth Fault Relay D2K-OG50 IEC 255, KEMC 1120, and KEPCO Overcurrent (50/51) 3Phase, Earth Fault(50N/51N) AC 110/120V and DC 110/125V ±30%, 9W(Non oper) 16W(Oper) AC 5A, 50/60㎐ Burden OC/EF 0.3VA Overcurrent : 0.2~15A(0.1A step) OC Instantaneous : 5~80A (1A step) Time lever : 0.1~15(0.1 step) Setting range Inst Time Overcurrent : 0.1~5A(0.1A step) EF Instantaneous : 3~40A (1A step) Time lever : 0.1~15(0.1 step) Time curve 장강반한시(LT-VI), 반한시(N-IN), 강반한시(V-IN), 초반한시(E-IN) IEC std. 반한시(NIES), 강반한시(VIES) KEPCO std. Resetting value Set of > 95% Reset time 50ms±25ms Degree protection IP52 Short current 80 In Communication Key-pad RS232(Front view), RS485(Reare view) Mode, ESC, Enter, Direction Key(�,�,�,�) RUN(Green) : C.P.U Error 동작상태 감시 및 전원감시 COMM(Yellow) : 깜박일때 신호 출력 중 Indicator Pick-up(Red) : Pick-up 과부하 동작시 점등 ERR(Red) : 내부회로 및 소자 불량시 점등 R.S.T.N : 동작 상표시 INST : 단락상태 표시등 Fault Memory Reset Temperature Mounting Contact capacity 10회 Memory 기능 및 사고선로별 회로표시 (선입선출방법,“1” 이 최근 사고를 뜻함 Memory event recording time 1.2sec Auto Reset, Indicator(Manual Reset) Operating temperature -10~60℃ Storage temperature -20~70℃ Flush mounted type Make AC 250V 15A 0.5sec(L/R=0), DC 125V 30A 0.5sec Break AC 250V 3A 0.5sec(L/R=0), DC 125V 30A 0.5sec Main trip 2a CPU Error : SCADA 1a, alarm 1a Output capacity OC과부하 : SCADA 1a, alarm 1a OC단락 : SCADA 1a, alarm 1a EF과부하 : SCADA 1a, alarm 1a EF단락 : SCADA 1a, alarm 1a Life time Withstand voltage Lightning impulse withstand voltage Surge transient Electromagnetic fild 2㎸ for 1minute between all terminal 1.2㎲/50㎲ 5㎸ Positive/Negative electrodes, 3times 2.5㎸/1㎒ (IEC255-4) 5W transceiver 150㎒-400㎒/0.3m (IEC 1000-4-3 c1.2) Transient Bust immunity Aux. power. contacts. current-4㎸ (IEC 255-22-4) Electrostatic discharge 8㎸ in air, 6㎸ by contacting Vibration Shock 22 기계적 수명 : 10×106 / 전기적 수명 : 2×105 DEESYS TOTAL PRODUCTS GUIDE Vibration frequency : 16.7㎐ Double amplitude:0.4㎜ Direction:horizontal, vertical, transverse Shock acceleration : 50G Shock application direction:horizontal, vertical, transverse Shock times : 3 times 40ms D2K-OG50 Series 3-Phase Over Current and Earth Relay[50/51,50/51N] Front View LED Indicator Display General Setting Level Setting point Fault check Communication Self test mode CPU(RUN)Error check & Aux. Power Pick-up indicator System Error indicator Fault indicator Comm. conection indicator Key Part Key part Top menu mode key Escape Key menu Cursor menu key Up�Down menu Right�Left menu Communication Part Reset RS232 Serial Part Lamp and CPU reset Menu Specification Start on display �CPU RESET S/W를 입력하거나 전원을 ON/OFF 하면 초기상태가 됩니다. Fault Check Mode Fault current, time, phase �[MEMORY VIEW] Mode가 나올때까지 MODE Key를 입력합니다. Line on Display Mode �각상 전류(Line Check)확인은 정상 운전시에는 항상 각 상의 전류 를 인식하여 LCD 창에 1차 및 2차 전류값을 표시합니다. �방향 Key를 입력하면 최종 사고 횟수, 사고 상, 사고 TYPE, 사고전류, 사고 Cycle, 사고 시간, 사고 날짜등을 확인 할 수 있습니다. 최종 10회까지 사고치를 기억하고 있으며 그 이상의 값은 최종 Date가 새로 입력되면 제일 먼저 입력된 Date부터 지워집니다. 이 기억 된 값은 EEPROM에 기억되므로 전원 상실시에도 유지됩니다. 먼저 입력된 사고 Date를 확인 하고자 할 때에는 위 Display Mode에서 좌, 우 방향 Key를 입력하면 됩니다. �사고 Memory는 최대 10회까지 기억됩니다. Setting View �[Setting view] Mode가 나올때까지 Mode Key를 입력합니다. �방향 Key를 입력하여 현재의 계전기 Setting 상태를 확인 할 수 있습니다. DEESYS TOTAL PRODUCTS GUIDE 23 D2K-OG50 Series 3-Phase Over Current and Earth Relay[50/51,50/51N] General Setup CT ratio setup System setup System의 날짜, 입력 주파수, C/T Ratio Ini Display 상태등을 변경 할 수 있습니다. �MODE Key를 이용하여 [GENERAL SETUP] 상태가 되도록 입력 합니다. �MODE Key를 이용하여 [GENERAL SETUP] 상태가 되도록 입력합 니다. �위 Display 상태에서 1 .SYSTEM SET에 Cursor를 위치하고 Enter Key를 입력합니다. �위 Display 상태에서 1 .SYSTEM SET에 Cursor를 위치하고 Enter Key를 입력합니다. Frequency setup �MODE Key를 이용하여 [GENERAL SETUP] 상태가 되도록 입력 합니다. �위 Display 상태에서 1 .SYSTEM SET에 Cursor를 위치하고 Enter Key를 입력합니다. �위 Display 상태에서 C/T Ratio에 Cursor를 위치하고 Enter Key를 입력합니다. �위 Display 상태에서 방향 Key를 이용하여 변경 하고자 하는 C/T Ratio를 입력 하고 Enter Key를 입력하면 변경된 값이 저장 됩니다. 최대 9999A까지 입력 가능합니다. �위 Display 상태에서 Line Freq에 Cursor를 위치하고 Enter Key를 입력합니다. �위 Display 상태에서 방향 Key를 이용하여 변경 하고자 하는 주파 수를 입력하고 Enter Key를 입력하면 변경된 값이 저장됩니다. Auto test setup Start on MODE 가기 �위 Display 상태에서 Auto Test에 Cursor를 위치하고 Enter Key를 입력합니다. �전면판에 있는 ESC Key를 입력하면 초기 MODE로 전환됩니다. �위 Display 상태에서 Auto Test에 Setting값을 변경 하고자 할때에 는 Up/Down Key를 입력하여 값을 변경하고 Enter Key를 입력하 면 자동으로 System을 Test 합니다. 24 DEESYS TOTAL PRODUCTS GUIDE D2K-OG50 Series 3-Phase Over Current and Earth Relay[50/51,50/51N] 표시기능 Pickup LED OC 또는 EF 요소중 전류치가 정정값에 접근하면 이 PICKUP LED가 깜박거리고 지속으로 켜지면 아래와 같이 Display합니다. (OC-A Phase) RUN LED AUX, Power가 정상적이면 녹색 LED가 점등됩니다. ERR LED SYSTEM에 이상이 있거나 CPU ERROR가 발생하면 점등됩니다. COMM LED 외부 기기와 접속하여 통신중 일때 점등됩니다. Operating Characteristic Curves 이 계전기는 7가지의 반한시 요소, 정한시 요소를 내장한 계전기로 특성 선택시 다음과 같이 선택 할 수 있으며 국제규격 IEC표준과 KEPCO 사양을 채택 하였습니다. DEESYS TOTAL PRODUCTS GUIDE 25 D2K-OG50 Series 3-Phase Over Current and Earth Relay[50/51,50/51N] 26 DEESYS TOTAL PRODUCTS GUIDE D2K-OG50 Series 3-Phase Over Current and Earth Relay[50/51,50/51N] Characteristic Curves - IEC & ESB6 ×Tap (IEC) I ( )-1 Ip A ∙LT-VI(장강반한시)= B ∙N-IN(반한시)= ( C ∙V-IN(강반한시)= ( D ∙N-IN반한시)= ( E ∙V-IN(강반한시)= ( F ∙E-IN(초반한시)= G ∙DT(정한시) = Tap(IEC) Tap:Time lever, I:Fault current(CT 2’ ry), Ip:Current set. value 0.11 Tap + 0.42 )× (KEPCO) I 0.02 10 ( ) -1 Ip 39.85 Tap +1.084 )× (KEPCO) I 1.95 10 ( ) -1 Ip 0.24 I 0.4 ( ) -1 Ip +0.12 )×Tap(IEC) 1.6 +0.04 )×Tap(IEC) I ( )-1 Ip 8 ×Tap(IEC) I ( )-1 Ip DEESYS TOTAL PRODUCTS GUIDE 27 D2K-OG50 Series 3-Phase Over Current and Earth Relay[50/51,50/51N] Operating time table �Normal inverse -IECLever Time 0.5 1 2 3 4 5 6 7 8 9 10 �Very inverse -IEC- T2 T3` T5 0.44 0.87 1.74 2.62 3.48 4.36 5.23 6.10 6.97 7.84 8.71 0.28 0.55 1.11 1.67 2.22 2.78 3.33 3.88 4.44 4.99 5.55 0.19 0.39 0.77 1.16 1.54 1.93 2.31 2.70 3.09 3.47 3.86 T10 0.14 0.28 0.56 0.84 1.12 1.40 1.67 1.96 2.23 2.51 2.79 Lever Time 0.5 1 2 3 4 5 6 7 8 9 10 T20 0.11 0.22 0.45 0.67 0.90 1.12 1.34 1.57 1.79 2.01 2.24 �Extremery inverse -IECLever Time 0.5 1 2 3 4 5 6 7 8 9 10 T2 T3` T5 1.33 2.67 5.33 8.00 10.67 13.33 16.00 18.67 21.33 24.00 26.67 0.50 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 9.00 10.00 0.17 0.33 0.67 1.00 1.33 1.67 2.00 2.33 2.67 3.00 3.33 T10 T20 0.04 0.08 0.16 0.24 0.32 0.40 0.49 0.57 0.65 0.73 0.81 0.03 0.03 0.04 0.06 0.08 0.10 0.12 0.14 0.16 0.18 0.20 Lever Time 0.5 1 2 3 4 5 6 7 8 9 10 T2 T3` T5 0.42 0.83 1.66 2.49 3.32 4.15 4.98 5.81 6.64 7.47 8.30 0.27 0.54 1.07 1.61 2.15 2.69 3.22 3.76 4.30 4.83 5.37 0.19 0.38 0.76 1.14 1.51 1.89 2.27 2.65 3.03 3.40 3.78 Part Indicator T10 0.14 0.28 0.55 0.83 1.10 1.37 1.65 1.93 2.20 2.48 2.75 Lever Time 0.5 1 2 3 4 5 6 7 8 9 10 T20 0.11 0.22 0.44 0.66 0.88 1.10 1.32 1.54 1.76 1.98 2.20 Phase A-B Phase B-C Fault C-A A-B-C A-N B-N C-N Ground A-B-N Fault B-C-N C-A-N A-B-C-N 28 Operating Indicator(LED) Time Over A B ● ● ● ● ● ● ● ● ● ● ● DEESYS TOTAL PRODUCTS GUIDE ● ● ● T5 0.22 0.44 0.88 1.32 1.76 2.20 2.64 3.08 3.52 3.96 4.40 T10 T20 0.11 0.22 0.44 0.65 0.87 1.09 1.31 1.52 1.74 1.96 2.18 0.06 0.12 0.25 0.37 0.50 0.62 0.75 0.87 0.99 1.12 1.24 T2 T3` T5 3.00 6.00 12.00 18.00 24.00 30.00 36.00 42.00 48.00 54.00 60.00 1.50 3.00 6.00 9.00 12.00 15.00 18.00 21.00 24.00 27.00 30.00 0.75 1.50 3.00 4.50 6.00 7.50 9.00 10.50 12.00 13.50 15.00 T10 T20 0.33 0.67 1.33 2.00 2.67 3.33 4.00 4.67 5.33 6.00 6.67 0.16 0.32 0.63 0.95 1.26 1.58 1.90 2.21 2.53 2.84 3.16 T10 T20 0.08 0.15 0.31 0.46 0.61 0.77 0.92 1.08 1.23 1.38 1.54 0.06 0.12 0.24 0.36 0.48 0.60 0.72 0.84 0.96 1.08 1.20 �Very inverse -KEPCO- Fault indicator LED F.T Part T3` 0.42 0.84 1.68 2.52 3.36 4.20 5.04 5.88 6.72 7.56 8.40 �Long-Very inverse -IEC- �Normal inverse -KEPCOLever Time 0.5 1 2 3 4 5 6 7 8 9 10 T2 0.82 1.64 3.28 4.92 6.56 8.20 9.84 11.48 13.12 14.76 16.40 current Inst.Over Current C EF A B C ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● EF ● ● ● ● ● ● ●LED ON T2 T3` T5 0.75 0.50 3.00 4.50 6.00 7.50 9.00 10.50 12.00 13.50 15.00 0.32 0.64 1.28 1.92 2.55 3.19 3.83 4.47 5.11 5.75 6.38 0.14 0.29 0.58 0.87 1.16 1.045 1.73 2.02 2.31 2.60 2.89 D2K-OG50 Series 3-Phase Over Current and Earth Relay[50/51,50/51N] Wiring Terminal arrangement DEESYS TOTAL PRODUCTS GUIDE 29 D2K-OG50 Series 3-Phase Over Current and Earth Relay[50/51,50/51N] Dimension 30 DEESYS TOTAL PRODUCTS GUIDE 한국전기연구원 개발시험합격품 Digital Protective Relay ■Reclosing Relay [79] D RC-O41 자동재폐로계전기 Reclosing Relay[79] MODEL DRC-041(Draw out type) Funtion �Test �Counter erase �Set Checking (Pt, Rt, Wt, T1, T2, T3, Counter) �Reset (Lock out) �CPU Reset Permissible ambinet Temperature �-10℃ to +50℃ (Guaranted Performance) �-20℃ to +60℃ (Storage) Feature The auto-reclosing relay is designed with micro processor based electronic CPU. Which can be applied for any distribution line either coordinating with synchronizing relay or bus voltage supervising relay. As setting range is wide, the reclosing relay may coordinate with other protective relay or system easily. Since the relay has a self checking funtion. It can be shown the error message on the front plate of the relay as soon as detected. There is a delay timer with which discrepancy time between main and aux. contact of circuit breaker can be adjusted. Specification Application The relay is applied for 3 phase reclosing system up to 154kV transmission network. The relay has input for synchronizing relay or bus voltage relay where need for network operation or bus voltage supervision. Model �DRC-041(Draw out type) Rating �Aux. Power : DC110/125V(+100%, -20%) Setting Range �Prepare Time : 30+(5, 10, 20, 40, 75) ∑ (5Sec step, 30~180Sec) �Reclaim Time : 20+(10, 20, 40, 80, 130) ∑ (10Sec step, 20~300Sec) �Waiting Time : 1, 2, 3, 4, 5, 8, +∑ (1Sec step, 1~20Sec) �T1 Time : 0.1, 0.2, 0.4, 0.8, 1.5, +∑ (0.1Sec step, 0~3.0Sec) �T2 Time : 1, 2, 3, 4, 8, 15 +∑ (1Sec step, 0~30Sec) �T3 Time : 5, 10, 15, 30, 60 +∑ (5Sec step, 0~120Sec) Input Contact �25-a : Synchro Relay (Normal "a") �M/L : Manual Locking �63CB : Circuit breaker Pressure �50/51-a : Relay Contact �43RC : Reclosing switch ON/OFF �CB-a : Circuit breaker“a”Contact Output Contact �79B : OTLC Blocking �79M : Reclosing signal (During Reclosing pulse with) �79S : 50 Relay Blocking (During Reclosing pulse with) �79C : Relay Error (C.P.U, Power) �79F : Lock out (Fail) Continuous Counter Indicator �Cumulative number of reclosing Commands, up to 999 Reclosing pulse with 32 DEESYS TOTAL PRODUCTS GUIDE 500ms Insulation �2kV, 50/60Hz for 1Min �Between all terminals Connected for together and Earth Impulse Withstand �5kV, 1.2/50㎲ �Between all terminals Connected for together and Earth Time Chart(four times reclaim success) Reclosing Relay[79] 특징 Feature 이 자동 재폐로 계전기는 마이크로 프로세스 칩을 사용하여 선로사고 차단시 3상 일괄, 3회까지 자동 재투입 할 수 있는 계전기 입니다. 마 이크로 프로세스 칩을 사용하므로써 재폐로의 정확성을 확보하고 시간 설정범위의 폭을 넓혔으므로 어떠한 계통에서도 사용이 가능합니다. 자가 진단 기능을 내장하고 있어 CPU가 정상이 아닐 경우 에러 표시 가 나타납니다. 또한 차단기 보조 접점 시간차를 보정 할 수 있는 Time delay 요소가있습니다. The Auto-reclosing relay based on microprocessor technology is for 3phase reclosing distribution system. While Line fault occurs and circuit breaker(CB) is tripped by OCR, the Auto-reclosing relay makes the CB reclosed for three times at a time. By appling advanced technology, the relay has not only advanced reliable operation, but also wide range of time set and various function, interval failure of the relay like DC fail or CPU error etc. is shown by LED on the front plate. For the interval fault, a output contact is provided for remote control supervision. For adjusting purpose with aux. contact from CB, the relay is provide a time delay element. 적용 Application 이 3상 일괄 투입형 자동 재폐로 계전기는 154급 이하 방사상 선로에 사용할 수 있으며, 동기 계전기와 조합하여 동기 조건이 맞을 경우 투 입 할수 있는 기능도 내장되어 있습니다. 동기 조건이 필요 없는 선로 에서는 모선전압 감시 계전기와 조합하여 모선이 이상 없을 시 투입 조건을 만족하도록 하는 기능으로 사용됩니다. The three phase auto-reclosing relay is for radial transmission line below 160kv system. It can be coordinated with synchronizing relay for check live-line and live-bus or voltage detecting relay for main bus voltage. 명판 Front plate -기능 다이얼 : 정상 운전시 이 다이얼은 COUNT에 놓습니다. 릴레이 가 동작하면 동작 횟수에 따라 1st LED/ 2nd LED/ 3rd LED 순으 로 켜집니다. 이 LED는 RESET을 누르면 꺼집니다. Pt-Rt-Wt-T1T2-T3 순으로 돌리면 그 위치에서 Setting 값을 확인 할 수 있습니다. -디스플레이 기능 : 기능 다이얼을 COUNT에 놓아두면 재폐로 총 누 계 횟수를 지시합니다. -COUNT ERASE Button을 누르면 디스플레이의 누계 횟수가 지워집 니다. -POWER LED(Green) : Aux power가 정상이면 항시 켜져 있습니다. 만약 CPU 에러에 의한 꺼짐 상태라면, RESET를 누르면 복귀합니다. 만약 복귀되지 않을 경우 전문가에 의한 내부점검이 필요합니다. -SUCCESS LED(Green) : 재폐로가 성공적으로 완료되면 커집니다. 이 LED는 다음 재폐로 신호가 들어 올 때까지 켜져 있습니다. -FAIL LED(Red) : 재폐로를 실패하면 켜집니다. -PREPARE LED(Yellow) : 재폐로를 수행 중에 켜집니다. -25-a LED(Green) : 동기 조건이 맞았을 시 켜집니다. -Pt dip swith : 초기 준비 시간을 설정합니다. -Rt dip swith : 리클레임 타임을 설정합니다. -Wt dip swith : 웨이팅 타임을 설정합니다. -T1/T2/T3 dip swith : 1,2,3차 재폐로 시간을 설정합니다. Dips with 의 타임 정정값을 0(off)으로 놓으면 PASS기능을 합니다. 예를 들면 T3의 모든 swith 를 off로 놓으면 3회 재폐로는 수행되지 않습니다. -NORMAL/LOCK Switch : NORMAL측으로 놓으면 재폐로 기능 적 용이며 LOCK측으로 놓으면 재폐로 기능을 off합니다. -RESET : 재폐로 실패시 이 Button을 눌러 주어야 다음 사고시 재폐 로 기능을 수행합니다. -CPU RESET : CPU에러 발생시도 POWER LED가 DC전원 상실시 와 같이 꺼집니다. 이때 이Button 을 누르면 복귀됩니다. 만일 전원 이 정상이면서 복귀되지 않는다면 릴레이의 자체를 점검해야 합니다. - Menu Dial : The dial pointer will be set at COUNT for normal use. Accumulated reclosed times are summed on the display While reclosing is performing. 1st LED-2nd LED-3rd LED is/are lighted in order whenever succeeding. The LEDs are off by RESET Button. By turning the dial, PtRt-Wt-T1-T2-T3. Preset value is shown on the display. - COUNT ERASE : The button is for erasing of cumulated recolsed times. - POWER LED(Green) : The LED is lighted during Aux. power ON. If the LED is off caused by CPU Error, press RESET, The POWER LED will be ON. If not, the relay have to be checked in detail by specialist. - SUCCESS LED(Green) : If reclosing is performed successfully, the LED is lighted. The LED is ON, until next performing. - FAIL LED(Green) : The LED is lighted when auto reclosing is failed. - PREPARE LED(Yellow) : The LED is lighted under performing reclosing funtion. - 25-a LED(Green) : The LED is lighted when synchronizing condition is OK. - Pt : Preparing time set switch - Rt : Reclaim time set switch - Wt : Waiting time set switch - T1/T2/T3 : reclosing time set switches. If set value is 0, then the Tx will be passed. - NORMAL/LOCK : NORMAL means reclosing function in ON, while LOCK is off for the reclosing function. - RESET : After reclosing fail or one cycle of reclosing function, the RESET will return all initial condition of the reclosing relay for next performance. - CPU RESET : If CPU Error occurs, the POWER LED is off, the LED is on by pressing the CPU RESET. If the LED is not ON, the relay have to be checked in detail by a specialist. - TEST : Pressing one time, Performing 1st reclosing function. Pressing second(third) time with in reclaim time set, performing 2nd(3rd) time reclosing function. After three times performing. FAIL LED will be lighted by pressing one more time(4th). For initial condition, press RESET. ※ 자체 재폐로 시험 방법 재폐로 연동시험을 가상적으로 수행할시 과전류부(OC)는 순시로 설정하고 지락요소(EF)의 순시를 Lock 시킨후 한시로 동작할 수 있도록 설정한 후 재폐로 계전기와 연동시험을 하면됩니다. 1회 재폐로 OCR부의 순시로 동작 2회 재폐로GR부의 한시동작(시간 : 정한시-DEF- / 동작시간Lever : 최소 DEESYS TOTAL PRODUCTS GUIDE 33 Reclosing Relay[79] Terminal block Dimension DRC-041 DRC-041 Connection FEEDER PROTECTION & RECLOSING NOTEl ① : 재폐로 신호(100mS) ② : Trip Signal 1. LPS - 모선 LINE 전압활선 및 Synchro Relay Contact-Nomal Close 2. 43RC - 재폐로 사용 및 잠금 Switch(Normal Close) 3. 79SX - 순시 Blocking용 Aux, Relay, 79FX-Lock Out용 Aux, Relay, 79PX - Preparing Completed, 28RX - OCR System Error, 79CX - Red System Error 4. 외부신호중 사용하지 않는 다음의 신호는 (+)에 연결한다.〔 20-a(Terminal- 1번 단자), 60CB-a(Terminal- 3번 단자)〕 34 DEESYS TOTAL PRODUCTS GUIDE 한국전기연구원 개발시험합격품 Digital type Protective Relay ■Digital Over Current and Earth Fault Relay [50/51x3, 50/51N] ■Digital Over and Under Voltage Relay [59/27]3∅ ■Multifunction Over Current and Earth Fault Relay [50/51x3, 50/51N] ■Over Current Relay [50/51x2] [50/51x3] ■Ground Over Current Relay(Earth Fault Relay) [50/51N] ■Multifunction Over and Under Voltage Relay [59/27] ■Over and Under Voltage Relay [59/27]1∅ ■Ground Over Voltage Relay [64] ■Directional Ground Relay [67] ■High Voltage Zero-Phase Current Transformer [ZCT]HZR-Series ■Static Phase Open Relay [47] ■High Voltage Ground Relay [51G] 디지털형 계전기 Digital Over Current and Earth Fault Relay [50/51X3, 50/51N] Front View 1. 4X20 DISPLAY LCD - State and information Display 2. L.E.D INDICATOR - Trip phase and state indication 3. CONTROL KEY - Use to setting and check the state 4. CLEAR / VIEW - LAMP CLEAR & LCD BACKLIGHT 5. CPU RESET - Use to CPU rest Menu Specification 1. 4X20 LCD DISPLAY WINDOW 특징 � 각 상의 전류값을 표시하며 상태 및 셋팅을 확인 할 수 있는 정 � 이 디지털 과전류 계전기는 마이크로 프로세서 기술을 적용한 계전기로서 3상과전류 요소와 접지과전류 요소를 가진 계전기 입니다. OCR과 OCGR는 독립적으로 정정 가능합니다. 보호협 조는 (1)반한시, 강반한시, 초강반한시 이중 1개 요소와 순시 요소 또는 (2)정한시 적용할 수 있습니다. 본 릴레이는 마이크로 프로 세서 칩 및 A/D 컨버터등 최첨단 기술의 적용으로 기존의 기계 식이나 정지형 보다 월등히 정밀하고 정확히 동작합니다. 적용 � 이 디지털 계전기는 직접접지 또는 저항접지 개통인 배전선로 보호 및 수용가의 수전 변전소의 feeder 보호용에 적용할 수 있 습니다. 이 릴레이는 다기능 / 광범위의 정정이 가능하므로 설계 단계에서 정확하게 정정치를 계산하지 않아도 되므로, 릴레이 선 택이 용이합니다. 보로 표시해준다. 2. L.E.D INDICATOR � 제품의 동작상태를 표시해준다. - RUN : MAIN CPU의 동작여부를 확인할 수 있다. - PICKUP : 과전류 입력시 점등 - COMM : RS 485 통신의 동작상태를 표시 - R.S.T.N : 동작된 상을 표시 - INST : 순시동작을 하였을시 점등 - POWER : 전원의 동작상태를 확인할 수 있다. 3. 조작부 � 셋팅 및 상태를 확인하기위한 조작시 사용되는 버튼 - MODE : MAIN SETUP을 진입하기위해 사용된다. - ENTER : SETTING된 값을 확정할 때 사용된다. - ESC : 설정값을 취소하거나 상위메뉴로 빠져나오기위해 사용 된다. - ▲, ▼, ◀, ▶버튼 : MENU를 스크롤하거나 선정값을 조정, 커서 의 위치변경에 사용된다. 4. CPU RESET � CPU를 RESET할 때 사용한다. 단, 설정된값과 저장된 데이터는 지워지지 않는다. 5. CLEAR / VIEW � LAMP의 RESET 및 LCD의 BACKLIGHT를 동작시킬때 사용된다. - 1회 누름 : LCD의 BACKLIGHT 동작 - 2회 누름 : BACKLIGHT동작후 LAMP CLEAR 36 DEESYS TOTAL PRODUCTS GUIDE Digital Over Current and Earth Fault Relay [50/51X3, 50/51N] Menu Specification Main Menu 4. C/T RATIO - 사용 CT의 1차와 2차의 비율을 설정한다. ▶ 방향키 (▲, ▼, ◀, ▶)를 이용하여 CT의 1차측 값을 설정한다. 설정된 CT비율은 입력된 값이 계산되어 전면 LCD에 DISPLAY 된다. � 전원 투입시 초기화면 O V E R E A R T H C U R R E N T & F A U L T R E L A Y v . X X OPERATING SETUP � 전원 투입시 초기화면 � MODE 버튼을 누른후 나타나는 MENU 화면 [ 1 . S Y S 2 . O P E 3 . F A U M T R L A I N M E N U ] E M S E T U P A T I N G S E T U P T M E M O R Y [ 1 2 3 O P E . T O . L E . T O R C V C A T I N G S E T U P ] / I O C ( O C ) E R / C U R V E ( O C ) / I O C ( O G ) 4 . L E V E R / C U R V E ( O G ) [ M A I N M E N U ] 4 . S E L F T E S T 5 . S E C U R I T Y S E T 1. TOC/IOC(OC) 1. SYSTEM SETUP - RELAY의 통신 및 CT비 등의 설정을 할 수 있다. [ T O C / I O C ] [ O C ] T O C [ X . X ] L O C K ? [ N ] I O C [ X ] L O C K ? [ N ] 2. OPERATING SETUP - OC 및 OG관련 동작치 및 동작시간(커브)를 설정 할 수 있다. TOC : 과전류 설정항목이며 방향키(▲, ▼)를 이용하여 원하는 값을 설정한다. ▶ LOCK : 방항키(▲, ▼)를 이용하여 Y, N 값을 설정할 수 있다. Y로 설정시 TOC는 동작 하지 않는다. ▶ IOC: 순시전류 설정항목이며 방향키(▲, ▼)를 이용하여 원하는 값을 설정한다. ▶ LOCK : 방항키(▲, ▼)를 이용하여 Y, N 값을 설정할 수 있다. Y로 설정시 IOC는 동작 하지 않는다. ▶ 3. FAULT MEMORY - 최근 사고기록을 10개까지 확인할 수 있다. 4. SELF TEST - LAMP 및 RELAY 의 동작을 TEST할 수 있다. 5. SECURITY - PASSWORD 를 설정할 수 있다. 2. LEVER / CURVE(OC) System Setup [ L E V E R / C U R V E ] [ O C ] L E V E R [ X . X ] C U R V E [ N I ] � SYSTEM SETUP 상세 메뉴 F D C C R E O / E Q U E N C Y V I C E I D M M S P E E D T R A T I O [ [ [ [ X X 1 X X X 9 X ] H z ] 2 0 0 ] X X ] / 5 A 1. FREQUENCY - 입력 전류의 주파수를 조정한다. ▶ 방향키 (▲, ▼)를 이용하여 50 / 60Hz로 조정 할 수 있다. 2. DEVICE ID ▶ 방향키 (▲, ▼, ◀, ▶)를 이용하여 원하는 설정값을 입력한다. LEVER : OC에서 설정된 이상의 값이 입력시에 동작시간을 설 정하는 항목이며 방향키(▲, ▼, ◀, ▶)를 이용하여 원 하는 값을 설정한다. ▶ CURVE : 방향키(▲, ▼)를 이용하여 DT, NI, VI, EI 값을 설정할 수 있다. - DT : Definite Time - NI : Normal Inverse - VI : Very Inverse - EI : Extremely Inverse ▶ 3. TOC/IOC(OG) 3. COMM SPEED - RS 485 통신 사용시, 통신의 속도를 조정한다. ▶ 방향키 (▲, ▼)를 이용하여 9600bps / 19200bps 설정이 가능하다. [ T O C / I O C ] [ O G ] T O C [ X . X ] L O C K ? [ N ] I O C [ X ] L O C K ? [ N ] ▶ TOC : 지락과전류 설정항목이며 방향키(▲, ▼)를 이용하여 원 하는 값을 설정하다. DEESYS TOTAL PRODUCTS GUIDE 37 Digital Over Current and Earth Fault Relay [50/51X3, 50/51N] Menu Specification LOCK : 방항키(▲, ▼)를 이용하여 Y, N 값을 설정할 수 있다. Y로 설정시 TOC는 동작 하지 않는다. ▶ IOC: 지락순시전류 설정항목이며 방향키(▲, ▼)를 이용하여 원하는 값을 설정한다. ▶ LOCK : 방항키(▲, ▼)를 이용하여 Y, N 값을 설정할 수 있다. Y로 설정시 IOC는 동작 하지 않는다. ▶ SELF TEST � SELF TEST 상세메뉴 [ T O C / I O C ] [ I O C [ X ] 1 . T 2 . T 3 . T O C ] E S T E S T E S T L A M P R E L A Y S W I T C H 4. LEVER / CURVE(OG) 1. TEST LAMP ▶ 전면부의 L.E.D 불량여부를 검사하는 메뉴이다. [ L E V E R / C U R V E ] [ O C ] L E V E R [ X . X ] C U R V E [ N I ] LEVER : TOC에서 설정된 이상의 값이 입력시에 동작시간을 설정하는 항목이며 방향키(▲, ▼, ◀, ▶)를 이용하여 원하는 값을 설정한다. ▶ CURVE : 방향키(▲, ▼)를 이용하여 DT, NI, VI, EI 값을 설정할 수 있다. - DT : Definite Time - NI : Normal Inverse - VI : Very Inverse - EI : Extremely Inverse ▶ FAULT MEMOY [ L E M P T E S T ] [ E N T E R ] T O A L L L A M P [ E S C ] T O Q U I T L E S T - 위의 메뉴상태에서 ENTER KEY를 누르면 전면부의 모든 L.E.D가 점등하며, ESC KEY를 누르면 상위메뉴로 빠져나온다. 2. TEST RELAY [ R [ L E F T ] [ R I G H T [ E S C ] t E L A Y T E S T ] T O 0 C T R I P ] T O E F T R I P o Q U I T T E S T �FAULT MEMORY 상세 메뉴 - 위의상태에서 LEFT KEY(◀)를 누르면 OC RELAY가 TRIP하 며, RIGHT KEY(▶)를 누르면 EF RELAY가 TRIP한다. ESC KEY를 누르면 상위메뉴로 빠져나온다. [ F A U L T M E M O R Y ] 1 . F A U L T R E C O R D 2 . C L E A R F A U L T M E M 3. TEST SWITCH 1. FAULT RECORD [ F A U L T V I E W ] N 0 : 0 1 o f 1 0 r e c o r d s P h a s e : X A m p : X X X . X T y p e : x x x x C y c : x x x x x x ▶ ▶ 사고전류 입력된후 TRIP이 되면 최고 10회까지 사고내용이 저장된다. FAULT RECORD 선택시 나타나는 세부설정 항목 - NO : 기록값의 번호, 빠를수록 최근의 사고 기록이며 10개의 데이터 초과시 가장 나중값이 지워지며 다시 기록된다. - Phase : 사고발생 상을 표시한다. R, S, T상중 가장 먼저 TRIP이 발생한 사고상을 표시해준다. - Amp : 사고발생시 입력된 사고전류의 크기를 표시해준다. - Type : 사고의 종류를 표시한다. 한시사고(Time)와 순시사고 (Inst)를 표시해준다. - Cyc : 사고전류 입력시(Pickup)에서 Relay Trip까지의 시간을 Cycle로 표시해준다. 2. CLEAR FAULT MEM [ F A U L T C L E A R ] C L E A R F A U L T R E C ? ▶ 38 [ N ] 방향키(▲, ▼)를 이용하여 Y, N을 선택 할 수 있으며 Y선택시 저 장되어진 모든 사고 데이터가 삭제된다. DEESYS TOTAL PRODUCTS GUIDE [ S W I T C H T E S T ] [ ] < h e r e P r e s s & c h e c k s w i t c h [ E S C ] t o Q U I T T E S T - 위의 메뉴상태에서 각 Key를 누르면[ ]부분에 눌러진 Key의 값 이 표시된다. CPU RESET과 MODE KEY를 제외한 각 키의 불 량여부를 확인 할 수 있다. ESC KEY를 누르면 상위메뉴로 빠져나온다. SECURITY SET � SECURITY SET 상세메뉴 [ S E C U R I T Y P A S S W O R D P A S S W O R D ] [ * * * * ] s e t ’ 0 0 0 0 ’ t o d i s a b l e 1. SECURITY PASSWORD ▶ 제품의 PASSWORD를 설정하는 부분이다. - 패스워드를 사용하지 않는 경우 :“000” 로 설정한다. - 패스워드를 사용하는 경우 :“0001” ~” 9999”사이의 숫자를 입력한다. [패스워드가 활성화 되고하면 MODE번튼을 누를 때 마다 패스 워드를 묻게 된다.] - 패스워드를 잃어버렸을 경우 :“1183” 을 입력 한다. [1183을 입력할 경우 패스워드가“0000” 으로 초기화 된다.] Digital Over Current and Earth Fault Relay [50/51X3, 50/51N] MODEL ▶ DOG-D51D-N(DRAW OUT) ▶ DOG-D51-N(NON DRAW OUT) RATING Rated Current AC 5A Frequency 50/60Hz ± 5% Burden OC 0.5VA, EF 0.2VA Element (50/51) 3PHASE, 50N/51N Standard Code IEC 255, KEMC 1120 Auxiliary Voltage AC/DC 80~260V Memory Up to 10 records of Fault data Communication RS-485 Mod-bus Protocol(9600/ 19200bps) Ambient Temperature -10。~ 60。(with no icing) CONTACT AC 240V 10A 0.5sec (R/L=0ms) Make DC 1000W 0.5sec (R/L=0ms) Capacity AC 240V 3A 0.5sec (R/L=0ms) Break DC 30W 0.5sec (R/L=0ms) INSULATION Dielectric Withstacd 2KV for 1minute between all terminal Insulation Resistance �100MΪ Lightning Impulse Witihstand 5KV 1.2㎲ /50㎲ Surge Transient (DC 500V Megger) Positive/Negative 3Times 2.5KV 1MHz/ 200Ϊ CURRENT SETTING Type1 OC Standard EF Over Current : 0.2 ~ 15A (0.1A step) Insttantaneous : 5.0 ~ 80A (1A step) Over Current : 0.2 ~ 5A (0.1A step) Instantaneous : 1.0 ~ 40A (1A step) OPERATING TIME Over Current [LEVER 10] Earth Fault [LEVER 5] NI 300% : 6.30sec / 700% : 3.53sec VI 300% : 6.75sec / 700% : 2.25se EI 300% : 10.0sec / 700% : 1.67sec NI 300% : 3.15sec / 700% : 1.76sec VI 300% : 3.37sec / 700% : 1.12sec EI 300% : 5.0sec / 700% : 0.83sec TIME SETTING & CURVE (IEC 255-3) OC / EF Lever 0.1 ~ 40 Lever (0.1 step) Instantaneous Time Less than 50ms 0.14 tp t = � I 0.02 -1 10 13.5 tp t = � I - 1 10 80 tp t = 2 � I - 1 10 Normal inverse Time Very inverse Time Extremely Inverse Time Definite Time t = tp Resetting Value �90% Reset Time I:%Current (80% � 0.8) (120% � 1.2) tp : Time Lever �100ms DEESYS TOTAL PRODUCTS GUIDE 39 Digital Over Current and Earth Fault Relay [50/51X3, 50/51N] ■ Block diagram ■ Wiring ■ Terminal arrangement 40 DEESYS TOTAL PRODUCTS GUIDE Digital Over Current and Earth Fault Relay [50/51X3, 50/51N] Over current and earth fault relay (%)CURRENT (%)CURRENT (%)CURRENT (%)CURRENT DEESYS TOTAL PRODUCTS GUIDE 41 Digital Over & Under Voltage Relay [59/27]3 Front View 1. 4X20 DISPLAY LCD - State and information Display 2. L.E.D INDICATOR - Trip phase and state indication 3. CONTROL KEY - Use to setting and check the state 5. CLEAR / VIEW - LAMP CLEAR & LCD BACKLIGHT 4. CPU RESET - Use to CPU rest Menu Specification 1. 4X20 LCD DISPLAY WINDOW 특징 � 각 상의 전압을 표시하며 상태 및 셋팅을 확인 할 수 있는 정 � 이 다기능 과,부족전압 계전기는 마이크로 프로세서 기술을 적용 한 계전기로서 3상과전압 요소와 저전압 요소를 가진 계전기 입니다. OUVR은 독립적으로 정정 가능합니다. 보호협조는 (1)반한시, 정한시 이중 1개 요소와 순시 요소에 적용 할 수 있습니다. 본 릴레이는 마이크로 프로세서칩 및 A/D 컨버터등 최첨단 기 술의 적용으로 기존의 기계식이나 정지형 보다 월등히 정밀하고 정확히 동작 합니다. 적용 � 이 디지털 전압계전기는 발전기의 고장이나 선로사고시 또는 정 전시의 전압변동에 대응하여 1V 단위의 정밀정정이 가능하며, 동작시의 사고값이 기록되어 수/변전설비 보호용으로 적용할 수 있습니다. 보로 표시해준다. 2. L.E.D INDICATOR � 제품의 동작상태를 표시해준다. - RUN : MAIN CPU의 동작여부를 확인할 수 있다. - PICKUP : 과전압/부족전압 입력시 점등 - COMM : RS 485 통신의 동작상태를 표시 - AB, BC, CA : TRIP이 동작된 상을 표시 - UV, OV : UNDER VOLTAGE 및 OVER VOLTAGE의 동작 상태 표시 - INST : 순시동작을 하였을시 점등 - POWER : 전원의 동작상태를 확인할 수 있다. 3. 조작부 � 셋팅 및 상태를 확인하기위한 조작시 사용되는 버튼 - MODE : MAIN SETUP을 진입하기위해 사용된다. - ENTER : SETTING된 값을 확정할 때 사용된다. - ESC : 설정값을 취소하거나 상위메뉴로 빠져나오기위해 사용 된다. - ▲, ▼, ◀, ▶버튼 : MENU를 스크롤하거나 선정값을 조정, 커서 의 위치변경에 사용된다. 4. CPU RESET � CPU를 RESET할 때 사용한다. 단, 설정된값과 저장된 데이터는 지워지지 않는다. 5. CLEAR / VIEW � LAMP의 RESET 및 LCD의 BACKLIGHT를 동작시킬때 사용된 42 다. - 1회 누름 : LCD의 BACKLIGHT 동작 - 2회 누름 : BACKLIGHT동작후 LAMP CLEAR DEESYS TOTAL PRODUCTS GUIDE Digital Over & Under Voltage Relay [59/27]3 Menu Specification Main Menu OPERATING SETUP � 전원 투입시 초기화면 � 전원 투입시 초기화면 3 P H A S E O V E R & U N D E R V O L T A G E v . X X � MODE 버튼을 누른후 나타나는 MENU 화면 [ 1 . S Y S 2 . O P E 3 . F A U M T R L A I N M E N U ] E M S E T U P A T I N G S E T U P T M E M O R Y [ M A I N M E N U ] 4 . S E L F T E S T [ 1 2 3 O . . . E V E N R E V D A T I N G S E R V O L T A G E R / C U R V E E R V O L T A T U P ] E ( O V ) G E 4 . L E V E R / C U R V E ( U V ) 1. OVER VOLTAGE O V ▶ 1. SYSTEM SETUP - RELAY의 통신 및 PT비 등의 설정을 할 수 있다. P O L U ▶ [ O V E R [ X . X ] V O L T A G E ] L O C K ? [ N ] OV : 과전압 설정항목이며 방향키(▲, ▼)를 이용하여 원하는 값 을 설정한다. LOCK : 방향키(▲, ▼)를 이용하여 Y, N 값을 설정할 수 있다. Y로 설정시 OV는 동작 하지 않는다. 2. OPERATING SETUP - OV 및 UV관련 동작치 및 동작기간(커브)를 설정 할 수 있다. 2. LEVER / CURVE(OV) 3. FAULT MEMORY - 최근 사고기록을 10개까지 확인할 수 있다. [ L E V E R / C U R V E ] [ O V ] L E V E R [ X . X ] C U R V E [ N I ] 4. SELF TEST - LAMP 및 RELAY 의 동작을 TEST할 수 있다. System Setup � SYSTEM SETUP 상세 메뉴 F R E Q U E N C Y D E V I C E I D C O M M S P E E D [ X X ] H z [ X X ] [ 1 9 2 0 0 ] 1. FREQUENCY - 입력 전압 및 전류의 주파수를 조정한다. ▶ 방향키 (▲, ▼)를 이용하여 50 / 60Hz로 조정 할 수 있다. 2. DEVICE ▶ 방향키 (▲, ▼, ◀, ▶)를 이용하여 원하는 설정값을 입력한다. LEVER : OV에서 설정된 이상의 값이 입력시에 동작시간을 설 정하는 항목이며 방향키(▲, ▼, ◀, ▶)를 이용하여 원 하는 값을 설정한다. ▶ CURVE : 방향키(▲, ▼)를 이용하여 DT, NI 값을 설정할 수 있 다. - DT : Definite Time - NI : Normal Inverse ▶ 3. UNDER VOLTAGE [ T U V / I U V ] [ U V ] T U V [ X . X ] L O C K ? [ N ] I U V [ X . X ] L O C K ? [ N ] ▶ TUV : 부족전압 설정항목이며 방향키(▲, ▼)를 이용하여 원하 는 값을 설정한다. ▶ LOCK : 방향키 (▲, ▼)를 이용하여 Y, N값을 설정할 수 있다. Y로 설정시 TUV는 동작 하지 않는다. 3. COMM SPEED - RS 485 통신 사용시, 통신의 속도를 조정한다. ▶ 방향키 (▲, ▼)를 이용하여 9600bps / 19200bps 설정이 가능하다. DEESYS TOTAL PRODUCTS GUIDE 43 Digital Over & Under Voltage Relay [59/27]3 Menu Specification ▶ ▶ IUV : 순시 부족전압 설정항목이며 방향키(▲, ▼)를 이용 하여 원하는 값을 설정한다. LOCK : 방향키(▲, ▼)를 이용하여 Y, N 값을 설정할 수 있다. Y로 설정시 (▲, ▼) IUV는 동작 하지 않는다. 4. LEVER / CURVE(UV) [ L E V E R / C U R V E ] [ U V ] L E V E R [ X . X ] C U R V E [ N I ] SELF TEST � SELF TEST 상세메뉴 [ 1 . T E 2 . T E 3 . T E S S S S E L F T L A T R E T S W T M L I E S T ] P A Y T C H 1. TEST LAMP ▶ 전면부 L.E.D 불량여부를 검사하는 메뉴이다. LEVER : TUV에서 설정된 이상의 값이 입력시에 동작시간을 설정하는 항목이며 방향키(▲, ▼, ◀, ▶)를 이용하여 원하는 값을 설정한다. ▶ CURVE : 방향키(▲, ▼)를 이용하여 DT, NI 값을 설정할 수 있 다. - DT : Definite Time - NI : Normal Inverse ▶ [ L A M P T E S T ] [ E N T E R } T O A L L L A M P [ E S C ] T O Q U I T T E S T - 위의 메뉴상태에서 ENTER KEY를 누르면 전면부의 모든 L.E.D가 점등하며, ESC KEY를 누르면 상위메뉴로 빠져나온다. 2. TEST RELATY FAULT MEMOY [ R [ L E F T ] [ R I G H T [ E S C ] t � FAULT MEMORY 상세 메뉴 [ F A U L T M E M O R Y ] 1 . F A U L T R E C O R D 2 . C L E A R F A U L T M E M 1. FAULT RECORD ▶ 사고전압이 입력된후 TRIP이 되면 최고 10회까지 사고내용이 저장된다. ▶ FAULT RECORD 선택시 나타나는 세부설정 항목 [ F A U L T V I E W ] N 0 : 0 1 o f 1 0 r e c o r d s P h a s e : X V O L T : X X X . X T y p e : x x x x C y c : x x x x x x - NO : 기록값의 번호, 빠를수록 최근의 사고 기록이며 10개의 데이터 초과시 가장 나중값이 지워지며 다시 기록된다. - Phase : 사고발생 상을 표시한다. R, S, T상중 가장 먼저 TRIP이 발생한 사고상을 표시해준다. - Volt : 사고발생시 입력된 사고 전압의 크기를 표시해준다. - Type : 사고의 종류를 표시한다. 과전압/ 부족전압을 표시해 준다. - Cyc : 사고전압 입력시(Pickup)부터 Relay Trip까지의 시간 을 Cycle로 표시해준다. 2. CLEAR FAULT MEM [ F A U L T C L E A R ] C L E A R F A U L T R E C ? ▶ 44 - 위의상태에서 LEFT KEY(◀)를 누르면 OV RELAY가 TRIP하 며, RIGHT KEY(▶)를 누르면 UV RELAY가 TRIP한다. ESC KEY를 누르면 상위메뉴로 빠져나온다. 3. TEST SWITCH [ S W I T C H T E S T ] [ ] < h e r e P r e s s & c h e c k s w i t c h [ E S C ] t o Q U I T T E S T - 위의 메뉴상태에서 각 Key를 누르면[ ]부분에 눌러진 Key의 값 이 표시된다. CPU RESET과 MODE KEY를 제외한 각 키의 불 량 여부를 확인 할 수 있다. ESC KEY를 누르면 상위메뉴로 빠져나온다. SECURITY SET � SECURITY SET 상세메뉴 [ S E C U R I T Y P A S S W O R D P A S S W O R D ] [ * * * * ] s e t ’ 0 0 0 0 ’ t o [ N ] 방향키(▲, ▼)를 이용하여 Y, N을 선택 할 수 있으며 Y선택시 저 장되어진 모든 사고 데이터가 삭제된다. DEESYS TOTAL PRODUCTS GUIDE E L A Y T E S T ] T O 0 V T R I P ] T O U V T R I P o Q U I T T E S T d i s a b l e 1. SECURITY PASSWORD ▶ 제품의 PASSWORD를 설정하는 부분이다. - 패스워드를 사용하지 않는 경우 :“0000” 로 설정한다. - 패스워드를 사용하는 경우 :“0001” ~” 9999”사이의 숫자를 입력한다. [패스워드가 활성화 되고나면 MODE번튼을 누를 때 마다 패스 워드를 묻게 된다.] - 패스워드를 잃어버렸을 경우 :“1183” 을 입력 한다. [1183을 입력할 경우 패스워드가“0000” 으로 초기화 된다.] Digital Over & Under Voltage Relay [59/27]3 MODEL ▶ DOU-D33-N(NON DRAW OUT) ▶ DOU-D33D-N(DRAW OUT) RATING Rated Voltage AC 110V Frequency 50/60Hz ± 5% Burden OV 2VA, UV 2VA Element [59] 3PHASE, [27] 3PHASE Standard Code IEC 255, KEMC 1120 Auxiliary Voltage AC/DC 80~260V Memory Up to 10 records of Fault data Communication RS-485 Mod-bus Protocol Ambient Temperature -10。~ 60。(with no icing) CONTACT Output Relay Trip 2c (OV, UV) AC 240V 10A 0.5sec (R/L=0ms) Make DC 1000W 0.5sec (R/L=0ms) Capacity AC 240V 3A 0.5sec (R/L=0ms) Break DC 30W 0.5sec (R/L0ms) INSULATION Dielectric Withstand 2KV for 1minute between all terminal & case earth Insulation Resistance �100MΪ Lightning Impulse Witihstand 5KV 1.2㎲ /50㎲ Surge Transient 2.5KV 1MHz/200Ϊ (WithDC 500V Megger) Positive/Negative 3Times VOLTAGE SETTING Over Voltage Range 100~160V (1.0V step) Under Voltage Range 50~120V (1.0V step) Instantaneous : 20~90V (1.0V step) OPERATING TIME Over Voltage Inverse Time or Definite Time Under Voltage Inverse Time or Definite Time TIME SETTING & CURVE OV / UV Lever 0.1 ~ 40 Lever (0.1 step) Instantaneous Time Less than 50ms OV / UV Definite Time -0.85 � tp Ⅴ2.4 -1 t = ( 12.15 + 0.35) � Ⅴ2 -1 t = tp Resetting Value Over Voltage : V�90%, Under Voltage : V�110% Reset Time Less than 100ms UV Inverse Time OV Inverse Time V : % Voltage (80% � 0.8) (120% � 1.2) tp : Time lever t = tp 10 DEESYS TOTAL PRODUCTS GUIDE 45 Digital Over & Under Voltage Relay [59/27]3 ■ Block diagram ■ Wiring ■ Terminal arrangement 46 DEESYS TOTAL PRODUCTS GUIDE Digital Over & Under Voltage Relay [59/27]3 Operating time curves Under voltage relay Over voltage relay t= ( (Inverse time) (Definite time) (Inverse time) (Definite time) 12.15 tp +0.35) × V 2-1 10 DEESYS TOTAL PRODUCTS GUIDE 47 Digital Over & Under Voltage Relay [59/27]3 보호협조 Protective Coordination 전력 계통에 사용되는 계전기는 상위 계통에서부터 말단 부하에 이르 기까지 Level에 따라 협조가 이루어져야 합니다. 과전류 계전기의 적용시 고려해야 할 사항은 아래와 같습니다. Protective relays would be coordinated with other relays in the same system from main trunk line to end loads. Setting values of each OCR/OCGR according to each protection level is considered with following items. 1)보호구간 내에서의 단계별 단락 전류 산출. 2)보호구간 내에서의 단계별 과부하 전류 산출. 3)대용량 단위 설비의 열적 특성 확인. 4)전력용 변압기 등의 전압 초기 인가시 돌입전류와 시간특성 확인. 5)Power Fuse, ACB, MCCB등 한시 차단특성을 갖는 차단특성 확인. 6)기타 CT의 선정은 전문가와 협의함. 1) max. and minimum short currents(3 Phase to Ground) for protection section. 2) Overload level 3) Heat endurance characteristics of large equipments like Main transformer. 4) In-rush current during initial charge to large transformer. 5) Long time trip characteries of power fuse. ACB. MCCB and etc. 6) Saturation characteries of CT applied. 상기 1~5 항의 Data를 근거로하여 정정값을 계산합니다. 상위계통에서부터 말단부하 선로에 이르기까지, 자기구간 사고시만 동 작되고, 타 구간 사고시에는 동작되지 않는 범위에서 정정합니다. 정정 을 위한 협조는 아래의 계통도 및 특성 곡선도에서 보호범위를 참조 하십시오. In accordance with the data from the item 1 to 6, setting values are calculated. While a relay is working at a line fault correctly, other sections shall remain without anymaloperation. For protecting coordination, refer to the system network and characteristic curve, as the below figures. 계전기 적용계통도 One Line Diagram 보호협조 예 Protecting coordination F P1 Device No. ITEM 50/51 50N/51N 27 59 64 67 47 46/47/51/51N OCEF (3P4W) OCGR (EFR) UVR OVR OVGR DGR POR MPR 3E MPR 4E OCR (2 phase) (3 phase) 48 50/51,50N/51N DEESYS TOTAL PRODUCTS GUIDE Digital Over & Under Voltage Relay [59/27]3 개요 돌입전류 수전단의 차단기를 투입하면 구내 전기설비가 충전되어 과도전류가 흐릅 니다. 그러므로 ① 변압기의 여자돌입전류 ② 고압Condenser의 충전전 류에 대해서 수전단 OCR에 동작 영향을 고려해야 합니다. 변압기 여자돌입전류 변압기가 여자되지 않은 상태에서 1차측에 전압을 급격히 인가하면, 변압 기에는 역기전력이 발생해 있지 않기 때문에 철심의 자속이 일시적으로 포화되어 버립니다. 리액턴스분이 0 이되면, 변압기의 1차측이 단락된 것 과 동일한 상태이고, 과대전류가 과도적으로 흐릅니다. 제1차의 파고치는, 정격전류의 수배에서 수십배의 전류가 흐르기 때문에 peak 시간은 1~2Hz, 정격전류로 환원시까지는 2~3초 가량되는 경우도 있습니다. 이것을 여자돌입전류와 고압 콘덴서 충전전류를 참조하여 계전 기의 오동작 및 CB와의 보호 협조를 정확히 setting하여 주십시오. In-Rush Current of Transformer(3∅)6,600V Transformer cap. type oil filled transformer mold transformer Cap. (KVA) 20 30 50 75 100 150 200 300 500 750 1,000 1,500 2,000 10 20 30 50 75 100 150 200 300 500 750 1,000 Rated (A) 1.7 2.6 4.4 6.6 8.7 12.1 17.5 26.2 43.7 65.6 87.5 131 175 0.9 1.7 2.6 4.4 6.6 8.7 13.1 17.5 26.2 43.7 65.6 87.5 IN-Rush current(A) 0.01s 0.05s 0.1s 0.5s 1s 5s 28.3 43.3 64.8 76.0 94.7 117 146 218 308 462 616 755 896 15.6 27.2 41.6 62.0 88.7 111 151 190 252 420 504 616 16.8 25.7 4.05 47.5 59.2 77.0 95.6 146 212 325 433 542 672 9.2 16.2 24.7 38.7 55.4 73.1 99.0 125 169 295 354 443 12.8 19.6 21.4 36.8 45.8 60.5 75.1 119 178 274 366 472 616 7.0 12.3 18.9 30.0 43.0 57.4 77.8 98.2 138 249 299 385 5.7 8.8 14.2 16.6 20.7 27.5 34.1 57.9 86.5 137 183 259 364 3.2 5.5 8.5 13.6 19.4 26.1 35.4 44.6 66.8 125 150 212 4.2 6.4 10.1 11.9 14.8 20.2 25.0 40.0 62.5 101 135 189 252 2.3 4.0 6.2 9.7 13.9 19.1 25.9 32.7 47.2 91.8 110 154 1.9 2.9 4.7 6.6 8.7 13.0 17.5 26.2 43.7 65.6 87.5 131 175 1.0 1.8 2.8 4.5 6.6 8.7 13.0 17.5 26.2 43.7 65.6 87.5 In-Rush Current(A) Cap. Rated Cable (KVA) (A) Pick 10 0.9 2.6 t=0 149 6% Reactance Cap. t=0 Pick 0.9 - - 0.005s 0.01s 0.02s 0.05s 0.1s (KVA) 1.3 0.9 0.9 0.9 20 1.7 2.6 249 2.3 1.7 1.7 1.7 1.7 - - 50 4.4 2.6 336 5.2 4.4 4.4 4.4 4.4 3 5.9 100 6.6 3.2 428 12.5 6.7 6.6 6.6 6.6 4.5 8.9 200 8.7 4 503 38.2 10.5 8.7 8.7 8.7 6 11.7 500 17.5 22 736 146 40.3 18.2 17.5 17.5 12 23.6 750 43.7 50 1,226 544 256 82.0 43.9 43.7 30 58.9 1,000 65.6 80 1,548 919 564 233 72.0 65.6 45 88.3 87.5 100 1,819 12,383 1,057 636 105 92.9 60 In-Rush Current Once circuit breaker of receiving sector be passed with power, enclosured facilites get into the state of in-rush. There fore For ① exciting in-rush current of transformer occurs. ② relating for high voltage condencer charged. they should be noted that receiving sector is under operating effect. Exciting In-Rush Current of Transformer In the state of which transformer is not excited, once voltage is suddenly applied to primary, as counter electromotive force in transformer does not occur, core magnatic flux is temporarily saturated. In case that reactance is zero, primary of transformer is as in the state of short circuit, transient current keeps over flowing. Because peak value of primary wave passes several times to several ten times of rated currents, it would, at the peak of flowing time 1~2Hz, take 2 seconds to 3 seconds for getting returned to rated currents. This is what we call "excitation inrush currents and currents protective coordination between wrong-operating and circuit breaker shall be exactly set. In considering with exciting in-rush currents and current charged in high voltage condensers. 계산상의 조건 1. 전선길이 1km 2. 주파수 60Hz 3. 전압 6,600V 콘덴서에 선로상수를 통하여 전압의 파고치가 인가되는 경우의 과도전 류와, 정상상태로 흐를 경우의 교류전류를 가산하여 최대치를 표시합 니다. Over current in case that peak value of voltage is applied by use of line constant AC passing in normal state the above overcurrent and altenating current add up to maximam value. 118 DEESYS TOTAL PRODUCTS GUIDE 49 Multi Function Over Current and Earth Fault Relay[50/51 3, 50/51N] DOG-M51D 특징 Feature 이 다기능 과전류 계전기는 마이크로 프로세서 기술을 적용한 계전기 로서 3상 과전류 요소와 접지 과전류 요소를 가진 계전기입니다. OCR과 OCGR는 독립적으로 정정 가능합니다. 보호협조는 (1)반한시, 강반한시, 초강반한시, 중 1개 요소와 순시 요소 또는 (2)정한시 적용 할 수 있습니다. 본 릴레이는 마이크로 프로세서 칩 및 A/D 컨버터등 최첨단 기술의 적용으로 기존의 기계식이나 정지형 보다 월등히 정밀 하고 정확히 동작합니다. The multi-OCR is a microprocessor based digital type protective relay that has 3 phases overcurrent and ground overcurrent element which are provided with inverse, very inverse, extremely inverse, and definite time, curkes. OCR and GOCR can set the functions independently. The relay may be supplied in drawout type case or fixed type case according to customer's requirement. Its protceting coordination is configured with (1) one of time inverse curvesand instananuouse setting, or (2) definite time setting. The relay works more precisely and correctly than electmechanical type or static type, because of appling advanced digital converting technology. 적용 Application 이 다기능 계전기는 직접접지 또는 저항접지 계통인 배전선로 보호 및 수용가의 수전 변전소의 feeder 보호용에 적용 할 수 있습니다. 계전 기는 다기능/광범위 정정이 가능하므로, 설계단계에서 정확하게 정정 치를 계산하지 않아도 되므로, 계전기 선택이 용이합니다. The relay is suitable for solid or resistance grounded distribution feeder of utility company or cosumer's substation. Since the relay has multi-funtions and wide range settings. it is no necessary for engineer to calculate in detail at the beginning of design. Front plate 50 DEESYS TOTAL PRODUCTS GUIDE Multi Function Over Current and Earth Fault Relay[50/51 3, 50/51N] IEC255 JEC 2500, 2510 DOG-M51(Non Draw out) / DOG-M51D(Draw out) Specifications ●MODEL DOG-M51(Non Draw out) DOG-M51D(Draw out) ●Rating Rated current Frequency Auxiliary Voltage Ambient temperature ●Current setting -OCOvercurrent range Instantaneous -EFOvercurrent range Instantaneous ●Operating time Over Current Normal inverse time AC 5A 50/60㎐±5% AC/DC 110V(86~260V) -10℃ to 60℃(with no icing) ∙Very inverse time 2~10A/steps of 0.5A 20~80A/steps of 0.5A 0.2~2A/steps of 0.05A 1~40A/steps of 0.5A NI= VI= ∙Extremely inverse time EI= ∙Definite time D= 0.14 tp 10 tp � 10 tp � 10 tp ※I:Fault current(%) 10 ※tp:time lever 0.02-1 � 13.5 -1 80 2-1 2� Resetting Value > 95% Reset time < 100㎳ ●Burden Overcurrent Earth Fault Aux Voltage Very inverse time Extremely inverse time Instantaneous time Degree Protection Thermal Withstand Capability ●Vibration resistance Malfunction ●Shock resistance Destruction; for 1s 80xIn Continuously 3xIn 10㎐ 5mm double amplitude 30s each in X and Y directions 16.7㎐ 2.5mm double amplitude 600s each in X,Y, and Z directions 300㎨(approx. 30G) 3 time each in 3 directions ●Insulation to IEC 255 Dielectric withstand 0.5VA 0.5VA 12VA(AC),6W(DC) ●Contact Output Relay Trip 1c, Alarm 1a Trip & Alam contact capacity Make AC 240V 10A(L/R=0ms) DC 1000W 0.5Sec(L/R=0ms) Break AC 240V 3A(L/R=0ms) DC 30W 0.5Sec(L/R=0ms) ●Indicator Operating start CPU RUN Operating Extremely inverse time Earth Fault Normal inverse time ●Time setting & curve IEC 255-3 -OCOvercurrent time lever 0.25~40(Steps of 0.25 lever) Instantaneous Less than 40㎳ ∙Normal inverse time Very inverse time Lever #10 300% 6.3 sec 700% 3.5 sec 300% 6.75 sec 700% 2.25 sec 300% 10 sec 700% 1.67 sec Lever #5 300% 3.15sec 700% 1.76sec 300% 3.37sec 700% 1.12sec 300% 5.0sec 700% 0.83sec Lessthan 0.04sec IP52 Insulation resistance at 500V Impluse Voltage Withstand Surge transient simulator Weight 2kV for 1 minute between all terminals and case earthed. >100㏁ 5kV-1.2/50 ㎲ 2.5kV 1MHz/200Ϊ 2.2kg LED(Red) LED(Gre) LED(Red)Manual Reset DEESYS TOTAL PRODUCTS GUIDE 51 Multi Function Over Current and Earth Fault Relay[50/51 3, 50/51N] Over current and earth fault relay 52 DEESYS TOTAL PRODUCTS GUIDE Multi Function Over Current and Earth Fault Relay[50/51 3, 50/51N] 전류 정정방법 Current Setting Mode 한시전류 정정 변류기 비율을 참조하여 계약전력의 150% 부근에 정정합니다. Time limit Current setting In consideration of current transformer ratio, setting shall be conducted some where around contact demand 150% TAP ≒ 1 X 5 CT X (1.1~1.5) TAP ≒ TAP = 계전기의 정정 tap CT = Rated current of primary in transformer 한시시간 정정 전력회사와 협조하여 정정하십시요. 순시전류 정정 변압기의 돌입여자전류로 인하여 오동작하지 않도록 1차, 2차의 보 호협조를 고려하여 정정하십시오. 일반적으로 변압기의 용량으로 계 산하여 전류치의 1,000~1,600에 정정합니다. 1 X 5 CT X (10~16) Time limit setting Required to set current it cooperate with electric corporation concerned. Instantaneous current setting Required to set power in consideration of primary and secondary protective coordination so that wrong operating fault can not occur due to exciting rush current of transformer. Generally measuring capacity, setting shall be done at 1,000~ 1,600%(current value) TAP = 계전기의 정정 tap ‘ 1 X (1.1~1.5) = Current value of contact demand 1 CT = 변류기 1차 정격전류 TAP ≒ CT TAP = Relay setting tap = 계약전력 전류치(=계약전력(KW)/√ 3X6.6(kv)) 1 1 X 5 TAP ≒ = 계약전력 전류치(=계약전력(KW)/ 3X6.6(kv)) CT = 변류기 1차 정격전류 1 X 5 CT X (10~16) TAP = Setting tap 시험 1. 한시요소 시험시에 OC Test 스위치를 누르면 한시, 모든 순시 기 능을 할 수 있습니다. 2. 지락요소 시험시에도 E.F Test 스위치를 누르면 한시, 순시 기능 을 할 수 있습니다. 3. OC, EF 시험 및 동작표시 LED확인시에는 상시 전원전압을 연결 해야 합니다. 4. Setting Tap 눈금에 있는“Lock”기능은 계전기가 동작하지 않 는 위치이므로 시험후에는 정상위치로 돌려 놓으십시요. ‘ 1 = Current value based on KVA CT = Primary rated current of CT(Secondary Current 5A) Test 1. When testing of time limit element. one touch of OC test switch can perform both tests ,of time limit element and instantaneous element 2. All the test of grounding element with only pushing EF test switch, you can easily check the function of time limit and instantaneous element. 3. For OC and EF test and confirmation of operating indicator LED, you shall keep constant power voltage connected. 4. "Lock" on setting tap scale is the position where relay does not operate, after the test you shall get it back to ordinary position. Indication Fault Part Discription Operating Indicator Phase R-S Over Current Instantaneous overcurrent Earth Fault Over Current R S ● ● S-T T-R ● ● ● ● R-S ● ● S-T ● ● R.S.T ● T INST OC INST ● ● R.S.T T-R Earth Fault ● ● ● ● ● ● ● ● ● N ● Instantaneous ● ● DEESYS TOTAL PRODUCTS GUIDE 53 Multi Function Over Current and Earth Fault Relay[50/51 3, 50/51N] 동작특성 설명 Operating Characteristics 전면판의 모든 S/W는 Dip-Switch로 구성되어 있습니다. All switchs of front plate for relay are installed dip switdh Tripping time curve(CO) DE (Definite time) NI (Normal inverse) VI (Very inverse) EI (Extremely inverse) Tripping time curve(CO) DE (Definite time) NI (Normal inverse) VI (Very inverse) EI (Extremely inverse) Please select each curve as changing over the dip switch dip switch를 전환하여 각 curve를 선택합니다. Over current setting 한시전류는 2~10A로 구성되어 있고 0.5 A step으로 정정 가능합니 다. Dip switch는 ON-OFF로 구성되어 있고 ON사용시에 정정범위가 설정됩니다. 정정방법은 전면판에 수록되어 있고 값을 ON하였을 경우 모두 더하면 (∑) setting값을 설정됩니다. Over current setting The definitive current tap is limited for 2A to 10A and the tap is divided 0.5 step. Dip switch has ON-OFF position and it is able to set the setting range in case of“on”position Please refer to front plate how to set. But if you set setting current, you should plus the value of on position Is=2+1.0+2.0=5(A) ※ Lock위치로 ON-setting하면 ON기능이 동작하지 않습니다. Time lever setting Time lever는 0.25~40으로 0.25step단위로 setting 가능합니다. Time lever setting Time lever is limited from 0.25 to 4.0 sec and the tap is divided 0.25 step Ts=0.25+0.25+0.5+1.0+1.5+2.5+4.0 =10 lever Instantaneous current setting Inst, current는 20~80A로 정정되며 5A step으로 setting 가능합니 다. Instantaneous current setting The tap of instantaneous current is limited from 20A to 80A and the tap is divided 5A step. Is=2+1.0+2.0=5(A) ※ Lock위치로 ON-setting하면 ON기능이 동작하지 않습니다. 54 DEESYS TOTAL PRODUCTS GUIDE If the dip switch is set on lock position, the instantaneous function is not operated. Multi Function Over Current and Earth Fault Relay[50/51 3, 50/51N] Trip indicator 내부의 Relay가 동작하며 아래 각부의 동작상태를 LED Lamp로 확 인 가능합니다. Trip indicator when the aux relay is operated, it is able to confirm operating status of following parts and LED LAMP. Line check Line Check Switch를 누르면 각상에(T,EF) 흐르는 부하전류를 알 수 있습니다. Line check Push the line check switch, you can see the load current of each phase (T,EF) Fault check 사고로 부터의 신호가 발생하면 시간 경과후 CB가 차단하게 됩니다. 이때 사고의 상태(CT2차 전류)를 Display하는 동시에 사고 전류를 Memory합니다. 전원 또는 Line OFF후에도 S-RAM이 동작하기 때 문에 사고의 상태를 전원 재투입 후에도 Memory하고 있습니다. Momory Reset을 할 경우에는 Line check S/W와 Fault check S/W를 동시에 누르면 Momory가 소거됩니다. Fault check When there are some fault, the circult breaker will be shutdown after a few second. At that time, the status of fault(2ry current of CT) will be displayed and the current value of fault will be memoried due to operating S-RAM. After aux power turn off, the status of fault is memoried due to operating S-RAM In order to reset memory function, please push line check S/W and fault check S/W at the same time, and value of memory will be detected. Pick-up count 동작이 시작되면 count를 display에 표시하여 주기 때문에 동작 시간 상태를(%) 알 수 있습니다. Pick-up count On operating pick up count, it is able to see the time of trip operating(%) due to display the trip time counter Set check 각 설정한 Tap의 표시가 Display에 나타나기 때문에 각 setting tap 에 대한 설정 확인이 가능합니다. Set check It is able to confirm each setting tap value due to display the setting value an display window. OC tset & EF test 한시(CO) 기능을 자체 test 할 수 있어 Relay의 동작여부를 알 수 있 습니다. test시 time lever의 setting시간과 동일하게 동작하므로 동작시간 curve의 상태가 동시에 check됩니다. OC tset & EF test It is able to confirm the status of relay operating by the relay the function(CO.) The time setting of time lever and the operating time curve will be checked at the same time on testing If the run lamp is not operated, please push the reset button. Run Power부의 전원 감시 및 CPU의 동작이상 상태감시를 하고 있습니 다. RUN lamp On시 정상상태. (Run lamp OFF시 Error상태) 만약 RUN표시 lamp가 동작하지 않을 경우에 Reset Button을 눌러 주십 시오. Run On run position, it is indicated the status of power source and the operating status of CPU. (when run lamp turn on, it is good condition, and when run lamp turn off, it is error condition) Block diagram DEESYS TOTAL PRODUCTS GUIDE 55 Multi Function Over Current and Earth Fault Relay[50/51 3, 50/51N] Block diagram Non draw out Draw out Terminal arrangment Non draw out Draw out Terminal arrangement Digital type draw out 56 DEESYS TOTAL PRODUCTS GUIDE Cutting Size: 165 X 122mm Over Current Relay [50/51 2] [50/51 3] DOC-M32D , DOC-M42D 특징 Characteristics 기능 C.P.U를 내장하여 고신뢰도 및 정확도를 만족시키기 위해 MICOM화 하였습니다. Digital방식에 의한 고정밀화로 기능에 안정성을 실현하였 습니다. 자기감시기능을 채택하여 고장유무상태를 보다 신뢰성있게 향 상 시켰습니다. Multi function으로 표시 및 다기능에 충실하였습니다. Function Computerized by having C. P. U built-in the function to high reliability and accuracy and stabilized sopisticated function through digital system. Easy detection of malfunction with self-checking set. Convenient operation, based on multifunction. As target was installed, overload and short circuit can be clearly detected phase by phase. 표시선택 상시부하전류가 계측이 되어 Metering의 표시가 가능합니다. 정정치의 식별이 가능하여 setting후 정확한 위치가 표시됩니다. 유도 원판형의 회전표시에 대응하는 동작상태의 time counter가 표시되어 동작상태의 확인이 가능합니다. 구조 EMC에 대응하여 case구조 및 내부회로를 특수설계하여 고신뢰성을 확보하였습니다. 인출, 비인출형 구조로 되어있어 시공 및 현장 시험시 편리합니다. 계전기 인출시 CT회로 개방에 대한 대책이(Short bar)되어있어 CT의 소손을 방지할 수 있습니다. Front plate Display Convenient meter scale indicates the load state of currents passing all the time. Setting value of operating current is clearly discernable and correct position, also detectable after setting. With time counter setting it can surely confirm operating condition. Based on test SW, easy check-up can be performed. Construction Case construction corresponding to EMC and inner circuit was specifically designed for ensuring high reliability. Drawout and non-draw out type was so well constructed that setting and field test can be conveniently performed. When drawing out, short bar keeps CT circuits from burning down. 1. Current Display / Operating Count 2. Curr. Limits Element 3. Time Lever Element 4. Instantaneous Element 5. R-Phase Indicator 6. S-Phase Indicator 7. T-Phase Indicator 8. Over current Start Indicator 9. Power Lamp LED 10. CPU Run Indicator 11. Monitor Selection Switch 12. Time curve Selection Switch 13. Setting Check 14. Test 15. Fault Indicator 16. Draw-out Handle 17. Reset DEESYS TOTAL PRODUCTS GUIDE 57 Over Current Relay [50/51 2] [50/51 3] IEC255 JEC 2500, 2510 DOC-M32(Non Draw out) DOC-M32D(Draw out) DOC-M42(Non Draw out) DOC-M42D(Draw out) 2 phase 2 phase 3 phase 3 phase Specifications ●MODEL DOC-M32(Non Draw out) DOC-M32D(Draw out) DOC-M42(Non Draw out) DOC-M42D(Draw out) 2 2 3 3 ●Rating Rated current Frequency Auxiliary Voltage Ambient temperature Indicator Operating start CPU RUN Operating phase phase phase phase AC 5A 60/50㎐±5% AC/DC 110V(86~260V) -10℃ to 60℃(with no icing) ●Current setting Overcurrent range 2~10A Lock(Steps of 0.5A) 20~80A Lock(Steps of 5A) Instantaneous range ●Time setting & curve IEC 255-3 Overcurrent time lever 0.25~40(Steps of 0.25) Instantaneou Less than40ms (over 200%) NI= ∙Very inverse time VI= ∙Extremely inverse time EI= ∙Definite time DE= Resetting Value Reset time > 95% < 100ms ●Burden Overcurrent Aux Voltage Break DEESYS TOTAL PRODUCTS GUIDE 0.02-1 � 13.5 -1 80 2-1 2 � � � tp 10 tp 10 tp 10 tp 10 0.5VA 12VA(AC),6W(DC) ●Contact Output Relay Trip & Alam contact capacity Make 58 0.14 ∙Normal inverse time Trip 1c, Alarm 1a AC 240V 10A(L/R=0ms) DC 1000W0.5sec(L/R=0ms) AC 240V 3A(L/R=0ms) DC 30W 0.5sec(L/R=0ms) LED(Red) LED(Gre) LED(Red) ●Operating time Over Current Normal inverse time Very inverse time Extremely inverse time Instantaneous time Degree Protection Thermal Withstand Capability ●Vibration resistance Malfunction ●Shock resistance Destruction; ●Insulation to IEC 255 Dielectric withstand Insulation resistance at 500V Impluse Voltage Withstand Surge transient simulator Weight Lever #10 300% 6.3 sec 700% 3.5 sec 300% 6.75 sec 700% 2.25 sec 300% 10 sec 700% 1.67 sec 300% IP52 for 1s 80xIn Continuously 3xIn 10㎐ 5mm double amplitude 30s each in X and Y directions 16.7㎐ 2.5mm double amplitude 600s each in X,Y, and Z directions 300㎨(approx. 30G)3 time each in 3 directions 2kV for 1 minute between all terminals and case earth >100㏁ 5kV-1.2/50 ㎲ 2.5kV 1MHz/200Ϊ 2kg Over Current Relay [50/51 2] [50/51 3] Operating time curves Normal Inverse Very Inverse Extermely Inverse Definite Time DEESYS TOTAL PRODUCTS GUIDE 59 Over Current Relay [50/51 2] [50/51 3] 전류정정 방법 Current Setting Mode 한시 전류 정정 변류기 비율을 참조하여 계약전력의 150% 부근에 정정합니다. Time limit current setting In consideration of current transformer ratio, setting shall be conducted some where around contract demand 150% TAP ≒ 1 X 5 CT X 1.5 TAP ≒ TAP = 계전기의 정정 TAP = 계약전력의 전류치(=계약전력 (kw)/√ 3×6.6(kv) 1 1 X 5 CT X 1.5 TAP = Relay setting tap 1 CT = 변류기 1차 정격전류 = Current value of contact demand CT = Rated current of primary in transformer 한시시간 정정 전력회사와 협조하여 정정하십시요. Time limit setting Required to set current it cooperate with electric corporation concerned 순시전류 정정 변압기의 돌입여자전류로 인하여 오동작하지 않도록 1차, 2차의 보호 협조를 고려하여 정정하십시오. 일반적으로 변압기의 용량으로 계산하 여 전류치의 1,000~1,600%에 정정합니다. Instantaneous current setting Required to set power in consideration of primary and secondary protective coordination, that wrong operating fault can not occur due to exciting in-rush of transformer. Generally measuring capacity, setting shall be done at 1,000~1,600(current value) TAP ≒ 1 ′ X5 CT X (10~16) TAP = 계전기 정정 APT ‘ 1 = 변압기의 용량(KVA)에 의해 계산된 전류치 CT = CT 1차 정격전류(2차 전류는 5A) TAP ≒ 1 ′ X5 CT X (10~16) TAP = Setting tap ‘ 1 = Current value based on KVA CT = Primary rated current of CT(Secondary Current 5A) Dependent-time element current setting Contract CT Primary current(A) demand 5 10 15 20 30 40 50 75 100 150 200 300 (kw) (A)TAP α(%) (A)TAP α(%) (A)TAP α(%) (A)TAP α(%) (A)TAP α(%) (A)TAP α(%) (A)TAP α(%) (A)TAP α(%) (A)TAP α(%) (A)TAP α(%) (A)TAP α(%) (A)TAP α(%) 3 136 50 6 136 3.5 159 3.5 121 3 138 4 138 100 6 138 4.5 155 3.5 161 5 172 3.5 120 3 137 4 137 3 171 200 6 137 4.5 154 3.5 160 5 171 4 122 3.5 134 6 137 4.5 137 4 153 3 172 300 5 153 4.5 172 3.5 120 3 137 6 137 4 137 500 4.5 154 3.5 160 5 171 750 1,000 1,500 60 DEESYS TOTAL PRODUCTS GUIDE 6 137 4 4.5 5 122 137 153 6 137 3 137 3.5 160 3.5 4 4.5 5 120 137 154 171 6 137 3 137 3.5 160 4 4.5 5 122 137 153 3 137 3.5 160 Over Current Relay [50/51 2] [50/51 3] 동작특성 설명 Characteristics 1. 선로의 과부하 및 단락전류가 외부의 변류기를 통하여 본계전기의 입력단자에 흐르면 계전기 내부에 있는 각상에 대한 검출용과 전원 용 CT에 입력이 됩니다. 2. 검출된 회로에서는 입력레벨의 Filter를 거쳐 A/D컨버터와 마이크 로 프로세서에 의해 고장처리 및 동작표시기를 동작시켜줍니다. 3. 레벨 판정연산은 각상에 따른 사고(과부하, 단락)를 판정하여 각상 의 고장상태를 표시합니다. 표시기능 : 1)전류계측 2)시동 및 경과시간 3)각정정탭표시 1. In case overload or short circuit current is fed to input terminals of the relay from external transformer, the current will then flow to built-in transducers for phase current detection and power supply. 2. In the detection circuit, signal current of different by microprocessor to determine if the signal level reached pick up point to activate the relay. 3. The level deciding operation finds out faulty phase (overloaded, two phase short, or three phase short) line and indicates the by target of repective phase. The Function Includes indication of: 1) current measurement. 2)start and time elapse, and 3)value of set tap. 전류계측 각상에 흐르는 전류신호를 데이터 처리하여 전류계측 연산을 하여 상 에 흐르는 전류중 가장 높은상의 전류를 FND에 표시하여 주고 0.1A 이상부터 동작하여 표시합니다. 시동 및 경과시간 동작이 시작되면 카운트를 시작합니다. 이때 0~9까지의 경과시간을 두고 동작되며, 동작시작을 표시하는 operating start LED가 점멸 되어 동작진행을 알수 있습니다. 각 정정탭 표시 계전기의 정정 장치를 표시하는 기능으로 한시전류정정(A) 한시시간 정정(TAP)의 위치를 확인할 수 있습니다. Indication Indicator Circuit Trouble over current 2Phase instantaneous RS ST TR RST RS ST TR RST R ● … ● ● ● … ● ● S … … … … … … … … Current measurement The current of phase are date processed and operated for measurement of the currents. Only the largest current among phases but within the range of 0.2A and up to set value immediately before pick-up level is indicated by LED. Start and time elapse In case set value for start time limit is exceeded before starting, the indication turns to zero (0)which infer that the relay might activate to break in any moment. The time elapse is displayed counting from 0 tp 9 according to the 2 Phase level of current and at the moment display of 9 turns to 10, Trip the relay trips momentarily. At this instance, operating start T Instantaneous lamp (red LED) warns the operation by binking that time … … elapse lamp (red LED) warns the operation be pinking that ● … time elapse nearing trip is visibly noticeable. ● ● … ● ● ● … ● ● ● ● Confirmation display of set values The display indicates set values of OCR so that set values of time limit current(A) and time limit time(TAP) can be confirmed. Block diagram 3 Phase Indicator Circuit Trouble over current 2Phase instantaneous RS ST TR RST RS ST TR RST R ● ● ● ● … ● ● S ● ● ● ● ● … ● Trip T Instantaneous … ● … ● … ● … … ● ● ● ● ● ● ● DEESYS TOTAL PRODUCTS GUIDE 61 Over Current Relay [50/51 2] [50/51 3] Wiring Non draw out Draw out Non draw out Draw out Terminal Arrangement Non draw out Draw out Non draw out Draw out Dimension Case : ABS 난연성(Non flamable) Digital type draw out 62 DEESYS TOTAL PRODUCTS GUIDE Color : Black(N1.5) Cutting Size: 165 X 122mm Ground Over Current Relay (Earth Fault Relay)[50/51N] DCG-M22D 특징 Feature 이 접지 과전류 계전기는 마이크로 프로세서 기술을 적용한 접지 요소 를 가진 계전기 입니다. 보호협조를 위하여 1. 반한시, 강반한시, 초반한시 곡선중 1요소와 순시요소를 조합하여 정정하거나 2. 정한시 요소를 단독으로 적용 할 수 있도록 선택 할 수 있습니다. 이 계전기는 A/D컨버터 및 CPU를 내장하고 있기 때문에 일반 정 지형이나 기계식에 비하여 월등히 정확하고 신속하게 동작합니다. The OCGR is a microprocessor based digital type protective relay that has ground overcurrent detecting elements. For protecting coordination, it could be applied with: 1. Instant. GOC with one of normal inverse, very inverse, and extremely inverse curves or 2. Alone with definite time Since a fault level is treated by A/D converter and calculated by CPU, the fault detected, is more correct and precise than E/M type or static type. 적용 Application 이 접지 과전류 계전기는 직접접지 또는 저항접지계통에 적용 할 수 있으며, 정정범위가 넓어 설계단계에서도 리레이 선택이 용이 합니다. The OCGR is applied to solid ground or resistance ground network. More-over the relay could be chosen at the begining of design stage, since its adjustable range is wider than other relays. Front plate 1. Current Display / Operating Count 2. Curr. Limits Element 3. Time Lever Element 4. Io Element 5. Pick up Start Indicator 6. Power Indicator 7. CPU RUN Indicator 8. Monitor Select 9. Setting verify 10. Test Switch 11. Time curve Position Select 12. Operating Indicator(oc) 13. Operating Indicator(inst) 14. Reset Switch 15. Draw-out Handle DEESYS TOTAL PRODUCTS GUIDE 63 Ground Over Current Relay (Earth Fault Relay)[50/51N] IEC255 JEC 2500, 2510 DCG-M22(Non Draw out) DCG-M22D(Draw out) Specification ◆MODEL DCG-M22(Non Draw out) DCG-M22D(Draw out) ◆Rating Rated current Frequency Auxiliary Voltage Ambient temperature ◆Current setting Overcurrent range Instantaneous range ◆Operating time Over Current Normal inverse time AC 5A 60/50㎐±5% AC/DC 110V(86~260V) -10℃ to 60℃(with no icing) 0.2~2A Lock(Steps of 0.05A) 1~40A(Steps of 0.5A) 0.25~40(Steps of 0.25) Less than 40ms(over 200%) ∙Normal inverse time NI= ∙Very inverse time VI= ∙Extremely inverse time EI= 0.14 13.5 -1 80 2-1 2 DE= Resetting Value Reset time > 95% < 100ms Break LED(Red) LED(Gre) DEESYS TOTAL PRODUCTS GUIDE ◆Vibration resistance Malfunction tp tp 10 tp � 10 tp � 10 � 0.5VA 12VA(AC),6W(DC) ◆Contact Output Relay Trip & Alam contact capacity Make Degree Protection Thermal Withstand Capability 0.02-1 �10 ∙Definite time ◆Burden Overcurrent Aux Voltage 64 Extremely inverse time Instantaneous time ◆Time setting & curve IEC 255 Overcurrent time lever Instantaneous Indicator Operating start Operating Very inverse time Trip 1c, Alarm 1a AC 240V 10A(L/R=0ms) DC 1000W 0.5Sec(L/R=0ms) AC 240V 3A(L/R=0ms) DC 30W 0.5Sec(L/R=0ms) ◆Shock resistance Destruction; ◆Insulation to IEC 255 Dielectric withstand Insulation resistance at 500V Impluse Voltage Withstand Surge transient simulator Weight Lever #10 300% 6.3 sec 700% 3.5 sec 300% 6.75 sec 700% 2.25 sec 300% 10 sec 700% 1.67 sec Iess then 0.04 sec(200% overcurrent) IP52 for 1s 80xIn Continuously 3xIn 10㎐ 5mm double amplitude 30s each in X and Y directions 16.7㎐ 2.5mm double amplitude 600s each in X,Y, and Z directions 300㎨(approx. 30G) 3 time each in 3 directions 2㎸ for 1 minute between all terminals and case earth >100㏁ 5kV-1.2/50 ㎲ 2.5kV 1MHz/200Ϊ 2.0kg Ground Over Current Relay (Earth Fault Relay)[50/51N] Operating time curves Normal Inverse Very Inverse Extermely Inverse Definite Time DEESYS TOTAL PRODUCTS GUIDE 65 Ground Over Current Relay (Earth Fault Relay)[50/51N] 접지계산 방법 Calculation ● 중성점을 직접 도체로 접지하는 방식으로서 1선 지락전류는 단락전 류와 등가이다. 그러므로 다른 접지방식에 비하여 지락전류가 가장 크며 지락사고시 중심점의 전위 변화는 매우 적다. 따라서 변압기 및 전로의 절연강도를 내릴 수 있어 경제적이나 유도장해가 매우 커서 고속도차단이 필요하다. 또한, 고장전류가 많아서 계전기가 확 실하게 동작할 수 있고 신뢰도가 가장 높아 고압 계통에서 이 방식 이 많이 채택되고 있다. ● As a mode that neutral point grounds by means of conductor directly, one wire earthing current is equal to short current. So earth current is the largest one comparing with other grounding method. In case of earth fault time, the electric potential is very small. Accordingly, this can decrease insulation intensity level of transformer and power line, also be economical. But inductive disturbance is very serious problem. Therefore high speed circuit breaking should be instantly taken. Also this method is adapted in measurement of high voltage because of high reliability. ● 예를들어 6,600V의 중성점에 NGR 38Ω의 저항을 사용하였을 경 우에 1선 지락전류를 계산하여 보면 3Ea 6,600 Ea= Zo √3 Zo = 3RN = 3×38 (3 은 영상회로는 1선분의 전류를 다루는데 반해 RN에는 3선분의 전류가 흐르기 때문이다.) 3Ea 3×6,600/ √ 3 ∴Ig= Ea= = 100A Zo 3×38 Ig= ● Example 6,600V Neutral NGR 38Ω Resistance 3Ea 6,600 Ea= Zo √3 Zo = 3RN = 3×38 (3 RN is accountable for 1 line zero phase, and to RN flowes 3 lines zero phases.) 3Ea 3×6,600/ √ 3 ∴Ig= Ea= = 100A Zo 3×38 Ig= Block diagram Ig = ground fault current Wiring Non draw out Terminal arrangement Non draw out Demension Digital type draw out 66 DEESYS TOTAL PRODUCTS GUIDE Draw out Draw out Case : ABS 난연성(Non flamable) Color : Black(N1.5) Cutting Size: 165 X 122mm Multi Function Over and Under Voltage Relay[59/27] DOU-M22D [ 1∅ ] [ 3∅ ] 특징 Characteristics ● 종래의 과전압, 부족전압을 별도의 계전기로 사용하던 것을 과, 부 족 전압을 1대의 계전기에 내장하였습니다. ● 고정밀 기능과 다기능의 조합으로 보호협조 및 수배전단의 적용에 최적입니다. ● 계전기 전면에 정밀 Volt meter가 설치되어 있어 계측용으로 가능 합니다. ● 전자식 동작표시기 및 LED가 부착되어 있어 정전 및 사고상태의 판별이 명확히 표시됩니다. ● Up to now OVR and UVR relays were separately set and also operated but they are compacted in one relay unit. So very convenient for handling too. ● As assembled with state of art and multifunctions, it is most suitable and applicable to protective coordination. ● Volt meter being installed, it can be used fer measuring ● Electronic indicator target accurately show the troubles and surely indicate electric trouble. Front plate 1. Voltage Display / Operating Count 2. Voltage Limits Element 3. Time Lever Element 4. Instantaneous Element 5. Over Voltage Setting Element 6. Time Lever Element 7. Monitor Selection Switch 8. Over & Under Voltage State 9. CPU Run LED 10. Under Voltage Curve Setting 11. Over Voltage Curve Setting 12. Under Voltage Test 13. Over Voltage Test 14. Target 15. Draw-out Handle DEESYS TOTAL PRODUCTS GUIDE 67 Multi Function Over and Under Voltage Relay[59/27] IEC255 JEC 2500, 2511 Model DOU-M22(Non Draw out) DOU-M22D(Draw out) Specifications ◆MODEL DOU-M22(Non Draw out) DOU-M22D(Draw out) ◆Operating time Over Voltage Under Voltage Degree Protection ◆Rating Rated Voltage Frequency Auxiliary Voltage Ambient temperature AC 110V 60/50㎐±5% AC/DC 110V(80~260V) -10℃ to 60℃(with no icing) ◆Voltage setting Over Voltage range Under Voltage range 115~150V/(Steps of 5V) 20~100V/(Steps of 5V) ◆Time setting & Curve Definite time or Inverse time Over Voltage time lever 0.05~10.3(steps of 0.05) 0.05±25ms, 0.1~10S±10% Under Voltage time lever 0.05~10.3(steps of 0.05) 0.05±25ms, 0.1~10S±10% Under Voltage Instantaneous 20~80V(Steps of 5V) Resetting Value OV:V<95%, UV:V> 105% Reset time < 100ms ◆Burden Over Voltage Under Voltage Aux. Voltage Less than 2VA Less than 2VA 12VA(AC), 6W(DC) ◆Contact Out put Relay Trip & contact capacity Make Break ◆Indicator Operating start Operating 68 DEESYS TOTAL PRODUCTS GUIDE OV : 1C / UV : 1C AC 240V 10A(L/R=0ms) DC 1000W 0.5Sec(L/R=0ms) AC 240V 3A(L/R=0ms) DC 30W 0.5Sec(L/R=0ms) LED(Red) LED(Red) ◆Vibration resistance Malfunction ◆Shock resistance Destruction; ◆Insulation to IEC 255 Dielectric withstand Insulation resistance at 500V Impluse Voltage Withstand Surge transient simulator Weight Inverse or definite time Inverse or definite time IP 52 10㎐ 5mm double amplitude 30s each in X and Y directions 16.7㎐ 2.5mm double amplitude 600s each in X,Y, and Z directions 300㎨ (approx. 30G) 3 time each in 3 directions 2kV for 1 minute between all terminals and case earth >100㏁ 5kV-1.2/50 ㎲ 2.5kV 1MHz/200Ϊ 2.0kg Multi Function Over and Under Voltage Relay[59/27] 3 IEC255 JEC 2500, 2511 DOU-M33 DOU-M33D DOV-M33 DOV-M33D DUV-M33 DUV-M33D [59/27] 3∅ (Non Draw out) [59/27] 3∅ (Draw out) [59] 3∅ (Non Draw out) [59] 3∅ (Draw out) [27] 3∅ (Non Draw out) [27] 3∅ (Draw out) Specifications ◆Rating Rated Voltage Frequency Auxiliary Voltage Ambient temperature AC 110V 60/50㎐±5% AC/DC 110V(80~260V) -10℃ to 60℃(with noicing) ◆Voltage setting Over Voltage range Under Voltage range 100~160V/(steps of 5V) 50~120V/(steps of 5V) LED(Red) LED(manual Reset) ◆Operating time Over Voltage Under Voltage Degree Protection Inverse or definite time IP 52 ◆Vibration resistance Malfunction ◆Time setting & Curve Over Voltage time Under Voltage time Instantaneous time Reset Value Reset time INST. 0.1~10(steps of 0.1)±10% INST. 0.1~10(steps of 0.1)±10% Less than 60ms OV:V<95%, UV:V> 105% Less than 100ms ◆Burden Over Voltage Under Voltage Aux. Voltage Less than 2VA Less than 2VA 12VA(AC), 6W(DC) ◆Contact Output Relay ◆Indicator Operating start Operating(Trip) DOU-M33/M33D Trip 2c(OV,UV) DOV-M33/M33D Trip 1c.Alarm 1a DUV-M33/M33D Trip 1c.Alarm 1a Trip & contact capacity Make AC DC Break AC DC 240V 10A(L/R=0ms) 1000W 0.5Sec(L/R=0ms) 240V 3A(L/R=0ms) 30W 0.5Sec(L/R=0ms) ◆Shock resistance Destruction; ◆Insulation to IEC 255 Dielectric withstand Insulation resistance at 500V Impluse Voltage Withstand Surge transient simulator Weight 10㎐ 5mm double amplitude 30s each in X and Y directions 16.7㎐ 2.5mm double amplitude 600s each in X,Y, and Z directions 300㎨(approx. 30G) 3 time each in 3 directions 2kV for 1 minute between all terminals and case earth >1,000㏁ 5kV-1.2/50 ㎲ 2.5kV 1MHz/200Ϊ[IEC 255-6] 2.2kg DEESYS TOTAL PRODUCTS GUIDE 69 Multi Function Over and Under Voltage Relay[59/27] 1 , 3 Operating time curves Under voltage relay Over voltage relay 70 DEESYS TOTAL PRODUCTS GUIDE (Inverse time) (Definite time) (Inverse time) (Definite time) Multi Function Over and Under Voltage Relay[59/27] 1 Block diagram Wiring : Dou-M22, 22D Non draw out Draw out ※ Aux, Power는 별도의 AC/DC 100V를 사용하십시요 Terminal arrangement Non draw out Block diagram Draw out DEESYS TOTAL PRODUCTS GUIDE 71 Multi Function Over and Under Voltage Relay[59/27] 3 Wiring V-Connection 110V Y-Connection 110V Terminal Arrangement Non draw out Draw out √ Y-Connection190V/ 3 Demension Case : ABS 난연성(Non flamable) Digital type draw out 72 DEESYS TOTAL PRODUCTS GUIDE Color : Black(N1.5) Cutting Size: 165 X 122mm Over, Under Voltage Relay[59], [27] 1 DOV-M15D, DUV-M20D 개요 Introduction 이상 전압에는 발전기의 고장으로 인해 전압의 급상승과 정전시 또는 단락시에 전압이 저하됩니다. 전압계전기는 교류회로의 전압변동에 대 응하여 전압을 미리 정정하여 놓고 정정치 이상이 되면 검출하여 동작 하는 계전기 입니다. In abnormal voltage condition, voltage shall be dropped because of sudden increasing voltage due to generator's fault and power off or short circuit time. Normally, voltage relay setting shall be done priorly against the voltage variation. When voltage become over the setting value, voltage relay shall be operated. 특징 Characteristics ● 고정밀 반도체로 내부회로를 구성하여 반영구적으로 사용이 가능 하며 진동이나 충격에 오동작할 염려가 없습니다. ● A/D Converter 회로를 구성하여 입력전압을 FND로 Display 함으로 Volt Meter 대용으로 사용 가능합니다. ● 사고를 정확하게 표시하는 Target을 부착하였습니다. ● 소비 전력이 적어서 PT의 부담이 적어도 되므로 경제적입니다. ● Control voltage is obtained from power transformer secondary without requiring any separate source of power supply that system configuration wiring and handling are convenient. ● Internal circuit constructed of semiconductors offer semipermanent sevice life without worries for malfunctioning caused by mechanical vibration and shocks. ● A/D converter circuit offers digital display of input voltages(substitutes AC voltmeter) ● Target shall show the fault condition accurately. ● Due to low power consumption and low burden of PT, this relay is economical. Front plate 1. Voltage Display / Operating Count 2. Voltage Limits Element 3. Time Lever Setting Element 4. Instantaneous Element 5. Under Voltage Test 6. Monitor Selection Switch 7. Under Voltage Curve Setting 8. Operating Start LED 9. CPU Run LED 10. Target 11. Draw-out Handle DEESYS TOTAL PRODUCTS GUIDE 73 Over, Under Voltage Relay[59], [27] 1 IEC255 JEC 2500, 2510 DOV-M15(Non Draw out) DOV-M15D(Draw out) DUV-M20(Non Draw out) DUV-M20D(Draw out) Specifications ● Indicator Operating start Operating(trip) ● Model DOV-M15(Non Draw out) DOV-M15D(Draw out) DUV-M20(Non Draw out) DUV-M20D(Draw out) ● Rating Rated Voltage Frequency Auxiliary Voltage Ambient temperature ● Voltage setting Over Voltage range Under Voltage range Under voltage instantaneous range AC 110V 60/50㎐±5% AC/DC 110V(80~260V) -10℃ to 60℃(with no icing) Less than 2VA Less than 2VA 12VA(AC), 6W(DC) ● Contact Out put Relay Trip 1c, Alarm 1a Trip & contact capacity Make AC 240V 10A(L/R=0ms) DC 1000W 0.5Sec(L/R=0ms) Break AC 240V 3A(L/R=0ms) DC 30W 0.5Sec(L/R=0ms) 74 ● Vibration resistance Malfunction 115~150V/(steps of 5V) 20~100V/(steps of 5V) 20~80V/(steps of 5V) ● Time setting & Curve Definite time or Inverse time Over Voltage time 0.05~10.3(steps of 0.05) Under Voltage time 0.05~10.3(steps of 0.05) 0.05±25ms, 0.1~10S±10% Instantaneous time Less than 60ms Reset value OV:V<95%, UV:V> 105% Reset time Less than 100ms ● Burden Over Voltage Under Voltage Aux. Voltage ● Operating time Over Voltage Under Voltage Degree Protection DEESYS TOTAL PRODUCTS GUIDE Shock resistance Destruction; Insulation to IEC 255 Dielectric withstand Insulation resistance at 500V Impluse Voltage Withstand Surge transient simulator Weight LED(Red) Target(Manual Reset) Inverse or definite time IP 52 10Hz 5mm double amplitude 30s each in X and Y directions 16.7Hz 2.5mm double amplitude 600s each in X,Y, and Z directions 300㎨(approx. 30G) 3 time each in 3 directions 2kV for 1 minute between all terminals and case earth >100㏁ 5kV-1.2/50 ㎲ 2.5kV 1MHz/200Ϊ 2.0kg Over, Under Voltage Relay[59], [27] 1 Operating time curves Under voltage relay Over voltage relay (Inverse time) (Definite time) (Inverse time) (Definite time) DEESYS TOTAL PRODUCTS GUIDE 75 Over, Under Voltage Relay[59], [27] 1 Block diagram Wiring Non draw out Draw out Terminal Arrangement Non draw out Dimension Digital type draw out 76 DEESYS TOTAL PRODUCTS GUIDE Draw out Case : ABS 난연성(Non flamable) Color : Black(N1.5) Cutting Size: 165 X 122mm Ground Over Voltage Relay[64] DVG-M11D 특징 Characteristics ● 본 계전기는 수배전단의 비접지방식의 전력계통에 사용되는 지락과 전압계전기로 GPT를 이용하여 지락사고시 CB를 TRIP시키는데 사 용되는 계전기입니다. ● 지락시 GPT의 3차측에서(a,f간) 유기된 지락전압을 이용하여 동작 하는 계전기로 cable의 정전용량에 대해 오동작 우려가 없습니다. ● 소비전력이 적어 PT의 부담이 작아도 되므로 경제적입니다. ● 동작특성에 대한 구성은 정밀급 반도체로 구성되어 있어 오차범위 가 적습니다. ● 계전기가 동작되면 전자 동작표시가(Target)가 있어 사고후의 상태 를 알수 있습니다. ● The relay is used in non-grounded power system of distribution lines of power station for the purpose of tripping circuit breaker through the use of GPT. ● As it is operated by detecting ground fault from third end of GPT, no concen for malfunction caused by static capacity of cable to ground. ● It is enconomical to use as modest power dissipation formal PT. Accordingly smaller current limiting resistor(W) will be required. ● Since the operation is highly sensitive, it is adequate for use in detection grounding fault of generators. ● Target shall show the fault condition accurately. Front plate 1. Voltage Display / Operating Count 2. Voltage Limits Element 3. Time Lever Setting Element 4. Groud Voltage Test 5. Monitor Selection Switch 6. Time Curve Selection Switch 7. Groud Voltage Start LED 8. CPU Run LED 9. Trip Indicator(Manual Reset) 10. Draw-out Handle DEESYS TOTAL PRODUCTS GUIDE 77 Ground Over Voltage Relay[64] IEC255 JEC 2500, 2511 DVG-M11(Non Draw out) DVG-M11D(Draw out) Specifications ● MODEL DVG-M11(Non Draw out) DVG-M11D(Draw out) ● Operating time Over Voltage Degree Protection ● Rating Rated Voltage Frequency Auxiliary Voltage Ambient temperature AC 110V/190V 60/50㎐±5% AC/DC 110V(86~260V) -10℃ to 60℃(with no icing) ● Voltage setting Over Voltage range 10~85(steps of 5V) ● Time setting Over Voltage time tap Resetting Value Reset time ● Burden Over Voltage Aux. Voltage ● Shock resistance Destruction; 0.05~10.3lever(steps of 0.05) 0.05sec±25ms, 0.1~10sec±10% >85% Less than 100ms Less than 2VA 10VA(AC), 6W(DC) ● Contact Out put Relay Trip 1c, Alarm 1a Trip & Alarm contact capacity Make AC 240V 10A(L/R=0ms) DC 1000W 0.5Sec(L/R=0ms) Break AC 240V 3A(L/R=0ms) DC 30W 0.5Sec(L/R=0ms) ● Indicator Operating start Operating(trip) 78 ● Vibration resistance Malfunction LED(Red) Target(Manual Reset) DEESYS TOTAL PRODUCTS GUIDE ● Insulation to IEC 255 Dielectric withstand Insulation resistance at 500V Impluse Voltage Withstand Surge transient simulator Weight Inverse or definite time IP 52 10㎐ 5mm double amplitude 30s each in X and Y directions 16.7㎐ 2.5mm double amplitude 600s each in X,Y, and Z directions 300㎨(approx. 30G) 3 time each in 3 directions 2kV for 1 minute between all terminals and case earth >100㏁ 5kV-1.2/50 ㎲ 2.5kV 1MHz/200Ϊ 2.0kg Ground Over Voltage Relay[64] Operating time curves (Inverse time) (Definite time) Dimension Case : ABS 난연성(Non flamable) Digital type draw out Color : Black(N1.5) Cutting Size: 165 X 122mm DEESYS TOTAL PRODUCTS GUIDE 79 Ground Over Voltage Relay[64] Block diagram Wiring : DVG-M11, M11D Non draw out Draw out Terminal arrangement Non draw out 80 DEESYS TOTAL PRODUCTS GUIDE Draw out Directional Ground Relay[67] DDG-M22D 특징 Characteristics 비접지계의 지락보호 방식으로 사용되는 지락방향계전기는 배전계통의 1선지락시에 발생하는 영상전압과 영상전류로 동작하는 계전기입니다. ● 왜파에 대해서도 정확히 동작할 수 있도록 입력부에 정밀도 Filter 회로를 내장하였습니다. ● 영상전압(Vo) 입력부의 부담을 적게 하였으므로 부담이 적은 접지 용변압기 (G.P.T)한대로도 많은 계전기를 동시에 수용할 수 있습니 다. ● 고속 및 시간 정정탭이 설치되어 후비보호협조가 가능합니다. Directional ground relay being non-grounded type ground protection is activated by zero phase sequence voltage(tertiary voltage of GPT installed on bus line) and zero phase sequence current (secondary current of ZCT installed on each phase) ● A precision fillter circuit is employed at input end for accurate determination of the detection even when signal wave form is distorted. ● Since the burden of zero phase sequence voltage (Vo) input end is minimized, any single unit of small capacity ground potential transformer (GPT) can support several or more relays at one time. ● Taps provided for time limit setting offer convenient means of reserver protection. Front plate 1. Display 2. Io Element(G.V.T) 3. Time Elemnent 4. Vo Elemnent 5. Angle Elemnent 6. Vo Value Indicator 7. Io Value Indicator 8. CPU RUN Indicator 9. Power Indicator 10. Monitor Select S/W 11. Setting Check S/W 12. Test S/W 13. Frequency Select 14. Pick-up Indicator 15. Trip Indicator 16. Reset S/W DEESYS TOTAL PRODUCTS GUIDE 81 Directional Ground Relay[67] IEC 255 JEM 1394 DDG-M22 (Non Draw out) DDG-M22D(Draw out) Specifications ● Model DDG-M22(Non Draw out) DDG-M22D(Draw out) ● Rating GPT input ZCT Frequency Auxiliary Voltage Ambient temperature ● Current setting Operating Current Setting tap(lo) Voltage Setting tap(Vo) Characteristic angle Zone of operating ● Time setting Curve Operating Time tap Resetting Value Reset time AC 110/190 200㎃/100㎷ 50/60Hz±5% AC/DC 110V(86~260V) -10℃ to 60℃(with no icing) ● Indicator Operating(trip) ● Vibration resistance Malfunction 0.1-1.0A(0.1A step)±10% 5~82.5V(steps of 2.5V) 0~180。 (steps of 5。 ) ±90(Error±10。 )(lead) ● Shock resistance Destruction; 0.05~10s (steps of 0.05 sec) >95% <100ms ● Burden G. P. T terminal(G1, G2) Less than 1VA Aux. Voltage 8VA(AC) Operating time curve 82 ● Contact Out put Relay Trip 1c, Alarm 1a Trip & Alarm contact capacity Make AC 240V 10A(L/R=0ms) DC 1000W 0.5Sec(L/R=0ms) Break AC 240V 3A(L/R=0ms) DC 30W 0.5Sec(L/R=0ms) DEESYS TOTAL PRODUCTS GUIDE ● Insulation to IEC 255 Dielectric withstand LED 10㎐ 5mm double amplitude 30s each in X and Y directions 16.7㎐ 2.5mm double amplitude 600s each in X,Y, and Z directions 300㎨(approx. 30G) 3 time each in 3 directions 2kV for 1 minute between all terminals and case earth Insulation resistance at 500V >100㏁ Impluse Voltage Withstand 5kV-1.2/50 ㎲ Surge transient simulator 2.5kV 1MHz/200Ϊ Weight 2.2kg Directional Ground Relay[67] Phase-angle characteristices Block diagram Wiring Non draw out Draw out ※ 1. a,f간 결선 및 Z1,Z2 결선을 반드시 확인 하십시요. 2. ZCT 사양은 200㎃/100㎷(Nickel Core)용으로 사용하십시요 ※ 200mA/1.5mA ZCT Setting 가능(Option) Terminal arrangement Non draw out Draw out Dimension Digital type draw out Case : ABS 난연성(Non flamable) Color : Black(N1.5) Cutting Size: 165 X 122mm DEESYS TOTAL PRODUCTS GUIDE 83 High Voltage Zero-Phase Current Transformer (ZCT) HZR-Series HZR . HZS TYPE Sophisticated ZCT for supporting Ground fault relay ● 사용시 안정성을 추구하였고, 종래의 ZCT보다 저가품으로 설계되 었습니다. ● 사용전류 범위가 광폭형으로 설계되어 Cable 작업시 편리한 구조 로 되어 있습니다. ● 경구조물로 되어 있어 판넬 취부에 용이하고, Cable 선정에 따라 다른 종의 영상변류기가 구비되어 있습니다. ● It aims to provide excellent usability and safety, and designs more economical than conventional ZCT. ● With wide range of operation currents, it is conveniently structured for cabling nwork. ● Light and easy for panel setting and also various kind of ZCT according to selection cable. Specifications Item Rated Voltage(V) Rated curr.(A) Dia(∅) Freq.(㎐) Weight(㎏) HZR-050 HZR-065 6,600/3,300 150 50 50/60 0.75 6,600/3,300 200 65 50/60 1 HZR-080 6,600/3,300 400 80 50/60 1.7 HZR-100 6,600/3,300 600 100 50/60 2.3 3.4 HZR-120 6,600/3,300 800 120 50/60 HZR-150 6,600/3,300 1,000 150 50/60 4 HZR-200 6,600/3,300 1,500 200 50/60 5.5 Rated zero-phase pri. curr 200㎃/100㎷(Load 2㏀) Confroming to JEC 1201 Dielectric Strength characteristics : 6A Dielectric strength 22,000VAC, 50/60㎐ for 1min (between primary conductor and coil, and between Primary conductor and mounting flange) 2,200VAC,50/60Hz for 1min(between secondary coil and test coil) Insulation resistance >1,000MΪ at 500VDC (between each coils, and between each coil and munting flans Dimension Item A B C D E F G H Hole(∅) HZR-050 50 25 131 100 122 7 32 36 6 6 HZR-065 65 26 143 114 133 7 39 37 HZR-080 80 34 174 160 180 7 40 40 6 HZR-100 100 38 203 160 180 7 40 40 6 HZR-120 120 45 225 180 210 16 55 35 10 HZR-150 150 45 260 180 210 16 55 35 10 HZR-200 200 53 310 260 286 10 70 35 10 Specila Specification Mold ITEM Use of Relay Epoxy Mold 65∅,120∅ 150∅,200∅ HGR,DGR ※ 상기 제품은 주문에 의해 공급합니다. ※ DGR용 ZCT는 Nickel-core로 제작됩니다. 84 DEESYS TOTAL PRODUCTS GUIDE Static Phase Open Relay[47] DPR-011D, 019D 특징 Characteristics ● 전력계통의 전압결상 및 반상 기능으로 후비보호에 최적이며 전압 검출을 이용하여 구동시키므로 결선이 간편하고 고압 및 저압에 사 용되는 계전기 (PT 2차 사용) ● 결상이 되면 동작표시기(LED)가 설치되어 있어 사고의 판별이 명확 히 구분됩니다. ● 계전기는 3상 입력 전압이 있어야 정상동작 합니다. ●The relay is best suitable for back up protection reserve against loss and damage caused by open phase in power system and applicable to both high and low voltage without requiring power source. It offers wiring convenience since it is driven by detecting voltage ●When a phase open is detected, indicator lamp(LED) is turned on for the phase line so that the fault line is identified visibly. ●It will not operate when 3 phase line power is not available. Front plate Operating time DEESYS TOTAL PRODUCTS GUIDE 85 Static Phase Open Relay [47] DPR-011(Non Draw out) DPR-011D(Draw out) DPR-019(Non Draw out) DPR-019D(Draw out) Specifications ● Model DPR-011(Non Draw out) AC 110(3∅) DPR-011D(Draw out) AC 110(3∅) DPR-019(Non Draw out) AC 190(3∅) DPR-019D(Draw out) AC 190(3∅) ● Rating Rated Voltage(3∅) Frequency Auxiliary Voltage Ambient temperature ● Under voltage setting Rated voltage setting AC 110,190V 50/60㎐ Non Power -10℃ to 60℃(with no icing) 300㎨(approx. 30G) 3 time each in 3 directions 70~90%, ±10% ● Reverse Operating time Degree Protetion Less than 1sec IP52 ● Burden Rated burden 1VA ● Contact Out put Relay Trip-1c Alarm-1c Trip & Alarm contact capacity Make AC 240V 10A(L/R=0ms) DC 1000W 0.5Sec(L/R=0ms) Break AC 240V 3A(L/R=0ms) DC 30W 0.5Sec(L/R=0ms) 86 ● Shock resistance Destruction; 10㎐ 5mm double amplitude 30s each in X and Y directions 16.7㎐ 2.5mm double amplitude 600s each in X,Y, and Z directions ● Insulation to IEC 255-5 Dielectric withstand ● Open and Under voltage time setting difinite time Setting tap 1~4sec±10% ● Indicator Operating RVS Trip Resetting ● Vibration resistance Malfunction: LED(YEL) LED(RED) Manual Reset(Indicator) DEESYS TOTAL PRODUCTS GUIDE Insulation resistance at 500V Impluse Voltage withstand Surge transient simulator Weight 2kV for 1 minute between all terminals and case earth >100㏁ 5kV-1.2/50㎲ 2.5kV 1MHz/200Ϊ 2.2kg Static Phase Open Relay [47] Block diagram Wiring Draw out Non Draw out (DPR-serise) Terminal arrangement Non draw out Draw out DEESYS TOTAL PRODUCTS GUIDE 87 High Voltage Ground Relay [51G] DHG-021ND 특징 Characteristics 비접지식에 사용되는 고압 지락계전기는 공장 또는 고압설비 및 기기 의 지락 사고를 신속히 검출하는 무방향성 지락계전기로서 영상 변류 기와 조합하여 사용되는 계전기입니다. ● 고조파 및 Surge의 영향을 받지 않는다. ● 자체 스위치 시스템에 있어 계전기의 정상상태 확인이 가능합니다. ● 동작표시가 부착되어 있어 사고후 판별이 가능합니다. ● 인출형이 가능하여 점검 및 보수가 편리합니다. H. V ground relay is applied for protection of factories. HV heavy-duty facilities or the relative apparatus, detecting instantly earth-fault. This non-directional relay is inconbination with ZCT ● Free from high frequency or surge. ● With self checking switch set, normal operation can be easily confirmed at any operation at any time, if need. ● Indicator can detect any wrong-operation after earth fault. ● Easy check-up and maintainance. 설치시 주의사항 고압지락 계전장치는 과전류계전기에 비하여 검출하는 전류가 대단히 적기 때문에 다른 전력선으로부터의 유도나 공사상 부주의로 불필요한 동작, 오동작 또는 부동작의 원인이 되기 때문에 설치 및 운용에 있어 다음을 주의할 필요가 있다. ● 관통형 ZCT를 사용하는 경우의 접지공사 ● 관통형 ZCT에 Cable을 관통시켜 사용할 경우 실-드접지 위치는 인입용 cable의 어느 경우에도 원칙적으로 cable 1개에 대하여 1 점으로 접지한다. ● ZCT의 2차 배선은 2가닥을 합친상태에서 다른 전력선보다 최소한 30cm이상 거리를 띄울것(ZCT의 2차단자간의 전압은 수mV~수십 mV로 극히 작으므로 정전유도, 전자유도에 따른 영양을 받을수 있 다. 그러기 때문에 오동작을 방지하기 위하여 원칙적으로는 독립된 2심 일괄 실-드선을 사용하는 것이 바람직하다. 전력선과 근접하고 있을 때에는 반드시 실-드선을 사용해야 한다. 또한, 실-드선은 접 지를 해야한다. ZCT의 2차(kt,lt)는 상시 개방을 하여 두고 계전기 시험시에만 사용한다. k,l단자(Z1, Z2)는 절대 개방하지 말아야 한 다. 개방시 고압이 유도되어 감전사고의 원인이 발생하고 만약 ZCT 분리시에는 단락하여 둔다. Operation time 88 DEESYS TOTAL PRODUCTS GUIDE Installation Compared with overcurrent relay, the relay detects very little and raises unnecessory reaction. You shall pay attention to the following. ● Grounding in useing of through-type ZCT. ● Put cable into the through-type ZCT shield grounding location at any event ground at only point/per piece. ● ZCT secondary wiring distance shall be kept minimum 30Cm away then as in other line installation in the state of combining two line into one. This serves to protect wrong operation. Front plate High Voltage Ground Relay [51G] KS C4601 DHG-021N(Non Draw out) DHG-012ND(Draw out) Specifications ● Operating time KSC 4601 over 130% over 140% Degree Protection ● Model DHG-021N(Non Draw out) DHG-012ND(Draw out) ● Rating 1ry operating current 200㎃/100㎷(2㏀ Combination) 50/60㎐±5% AC/DC 110V±20% -10℃ to 60℃(with no icing) Frequency Auxiliary Voltage Ambient temperature ● Current setting Operating Current temperature 0.2-0.3-0.4-0.5-0.60.8-1.0-Lock(A) ● Time setting Curve Over current 130% Over current 400% 0.1~0.3sec 0.1~0.2sec ● Burden Aux. Voltage 10VA(AC), 6W(DC) ● Contact Out put Relay Trip & Alarm contact capacity Make Break ● Vibration resistance Malfunction: ● Shock resistance Destruction; ● Insulation to IEC 255-5 Dielectric withstand Insulation resistance at 500V Impluse Voltage with stand Surge transient simulator Weight 0.1~0.3sec 0.1~0.2sec IP52 10㎐ 5mm double amplitude 30s each in X and Y directions 16.7㎐ 2.5mm double amplitude 600s each in X,Y, and Z directions 300㎨(approx. 30G) 3 time each in 3 directions 2㎸ for 1 minute between all terminals case earth >1,000㏁ 5㎸-1.2/50㎲ 2.5㎸ 1㎒/200Ϊ 2.0kg Trip 1c, Alarm 1a AC 240V 10A(L/R=0ms) DC 1000W 0.5Sec(L/R=0ms) AC 240V 3A(L/R=0ms) DC 30W 0.5Sec(L/R=0ms) DEESYS TOTAL PRODUCTS GUIDE 89 High Voltage Ground Relay [51G] 지락사고 검출방식 Mode of detection 지락사고 검출방법에는 사용하는 계전기에 따라 ① 지락전류 검출방식 영상변류기 + 지락과전류 계전기 + 지락계전장치 ② 영상전압검출방식 : 지락과전압계전기 ③ 위상검출방식: 지락방향계전기의 방법이 있으나 변압기 2차측은 평 상 배전길이가 짧고 Feeder수가작은 것에는 ①,② 의 방법으로 검출하면 된다. 특히 전압측의 비접지 방식에서는 접지보상용 콘덴서의 적용이 필수적이다. The designation of relay varies as follows according to detecting method. ① GR Detection: ZCT + OCGR + GR apparatus ② GPT Detection : OVGR Relay ③ Phase Detection ; DGR Relay Where distribution line is very short and the number of feeder is small too. (1),(2) methods are applicable and suitable. Especially, in non grounding mode is required to apply the condenser of zero-phase detction unit ∴ 콘덴서계산식 C = 2lt 2πf √ 3V (F) lt : 계전기 정정치 ∴ Condenser C = fc √3V(A) ∴ 완전지락시 계산식은 lg = 2π 2lt 2πf √ 3V(A) (F) lt : Relay setting value ∴ Ground Fault lg = 2π fc √3V(A) 감도전류정정탭의 설정 Setting tap of sensitivity current 수용가 구내에 대지간 정전용량이 적으면 고압기기 등의 보호(미소자 락 전류에서 동작시키면 피해가 적다.) 를 생각하여 최소탭으로 놓는 것이 좋다. 그러나 구내에 고압케이블 배선이 많고. 100m 를 넘을 경 우에는 현행 KS의 제품은 비방향성이므로 200mA탭 이하에서는 수용 가 구내가 아니고, 구외의 (ZCT부터 전원측) 배선의 지락사고를 불필 요하게 동작되는 경우가 있다. 배전선의 미소지락 사고등으로 가끔 관 계없는 수용가측에서 정전이 되는 불편을 주고, 이와 같은 경우에는 탭을 1~2단계 높여서 400mA~600mA로 하면 불필요동작을 하지 않게 된다. 고압기기와의 보호관계상수용가 지락계전장치의 탭을 200mA로 놓을 경우 혹은 600mA, 800mA등 최고 탭에 대해서도 협 조가 안되는 경우에는 비접지식의 것으로, 방향성을 갖는 것을 사용하 면 불필요한 동작이 없고 충분히 만족을 시킬 수 있다. 이런 경우에는 방향성계전기인 DDG-M22형을 사용하면 된다. Conisidering that once electrostatic capacity in between service area in consumer end is small, and high voltage device shall be protected small, and high voltage device shall be protected(operation in tiny earth fault causes little damage)keeping tiny tap in minimum will be suitable. But when there are high voltage wiring in service area, ground fault can frequently occur. Accordingly, consumer end is troubled with power cut-off, due to tiny fault of power distribution. In such case, tap shall be raised 1~2 steps to as much as 400mA~600mA. Poor coordination continues caused by max tap, in non-grounding directional relay DDGM22 will get into normal role. 케이블 정전용량 일람표 Cable electrostatic capacity norminal area (㎟) for 0.2A setting (m) for 0.4A setting (m) 8 14 22 38 60 100 150 200 250 135 115 100 85 70 60 50 50 47 270 230 200 170 140 120 100 100 95 (CV cable 6,600) 90 DEESYS TOTAL PRODUCTS GUIDE 케이블 길이에 대한 충전전류 Cable length of charging current Voltage 3.3KV 6.6KV Item 3Core (3 ∅3W) 3Core (3 ∅3W) norminal (㎟) JISC3606(CV) ㎌/㎞ 8 14 22 38 60 100 150 200 250 0.63 0.78 0.90 1.11 1.14 1.41 1.62 1.65 1.77 8 14 22 38 60 100 150 200 250 0.63 0.75 0.84 0.99 1.17 1.41 1.65 1.62 1.65 케이블 길이에 대한 한계 전류치 Cable length of limit current High Voltage Ground Relay [51G] 지락보호 협조 Protective Coordination ● 지락보호에 대해서도 과전류계전기와 같이 전력회사의 보호방식에 대응하여 수용가측에서는 시한협조 및 지락전류 협조를 가질 필요 가 있다. ● 특히 파급사고의 대부분이 지락사고에 따른 것이다. 그러므로, 적어 도 ZCT부터 부하측에서 발생하는 것은 모두 수용가 측에서 차단하 는 것이 필요하다. ● 운용상에 있어서는 전력회사와 충분히 연락을 취하여 협의할 필요 가 있다. ● 일반적으로는 현행의 수용가용 고압지락계전장치는 한시적으로는 문제가 없고 감도전류치를 적절히 선정하는데 따라서 대개의 경우 배전용 변전소의 지락보호계전 장치와 협조가 된다. ● For the protection of ground fault, as in overcurrent relay, consumer shall have time and ground fault coordination corresponding with suppliers protective measures ● Most of ground faults are caused by influension effect. There fore consumers shall take action to break down grounding from the ZCT burden ● For the managing ground fault, consumer ends shall coordinate fully enough with power supplier. ● As a rule HVGR which consumer use, operates timely without any hitch. By choosing sensitivity properly. HVGR coordinates smoothly with, protective ground relay in distribution purposed-power plant. 지락보호 구성 Construction ● 지락보호를 하는데 있어서의 방식은 방향을 선택하여 차단하는 DGR이 있으며, GPT의 영상 전압만으로 동작하는 OVGR이 있다. ● OVGR은 전압요소에 따라서만 동작하기 때문에 보통 과전류계전기 와 같이 동작전압치는 가변되는 탭(일반적으로 25~60V)과 동작시 간을 변경하는 레버가 있어 가변이 가능하다. ● 지락계전장치의 감도는 JIS (고압지락계전장치)에서는 200mA, 400mA, 600mA 3점의 절체탭을 반드시 구비하여야 한다. (연속 절체는 안된다.) ● 예를 들면 235mA 또는 422mA와 같이 슬라이드 저항 등으로 미 소한 변화를 주는 것은 JIS에서는 불가로 되어 있다. 연속가변이 아 닌 탭을 부가하여도 관계없다. ● 동작시간은 과전류정정치의 130%에서 0.1~0.3초, 400%에서 0.1~0.2초로 되어 있다. 이 특성에서보면 반한시 특성을 가지고 있 는 것 같이 보이나 실제는 정한시에 가깝다. ● In protection of ground fault, there are two kinds of relay : DGR for directional Selection and OVGR toroperating with Zero voltage from G. P. T. ● OVGR operates in accordance with voltage and time adustable Knob, each. ● High voltage ground relay shell be provided as following sensitivity Tap according to JIS 200mA, 400mA, 600mA ● The setting taps shell be fixed taps, not be linear sliding type like 235 or 422 instead of 200mA or 400mA. ● Operating time : Overcurrent Setting Valus 130%0.1~0.3secs, 400%-0.1~0.2secs. Based on the above characteristics. HGR seems to be inverse time characteristic. But it is definite time characteristic. 실-드 접지공사 방법(How to wiring the shield) DEESYS TOTAL PRODUCTS GUIDE 91 High Voltage Ground Relay [51G] Block diagram Wiring Non draw out Non Draw out ※ ZCT사양은 200mA/100mV용을 사용하십시요 Terminal arrangement Non draw out 92 DEESYS TOTAL PRODUCTS GUIDE Draw out High Voltage Ground Relay [51G] Dimension ● Digital type draw out Case : ABS 난연성(Non flamable) Color : Black(N 1.5) Cutting Size: 165 X 122mm ● Digital type non draw out / Static type DGR, POR, HGR Cutting Size: 165 X 122mm DEESYS TOTAL PRODUCTS GUIDE 93 Marine type Protective Relays ■Marine Type 3 Phase Voltage and Frequency Relay ■Marine Type 3 Phase Phase Fail Relay ■Marine Type 3 Phase Phase Sequence Indicator Relay ■Marine Type Single or 3 Phase Synchroscope 선박용 계전기 VOLT/Hz, PFR, PSI, SYNC 선박용 3-Phase Voltage and Frequency Relay DFV-011 특징 단상 전압 및 주파수 계전기로 High-Low setting이 가능하고 한 Unit에 내장되어 있어 전압과 주파수 콘트롤이 동시에 가능합니다. Specification Part Name Style 노출형(DIN Rail 사용기능) Type DFV-011 Connection Input Aux. Power burden Voltage set range 외부 VT 사용 또는 Direct 결선 VT : AC440V, Burden : 0.3VA, Frequency : 60㎐ DC24V, 10W Low : 90~100%(396~440V), High : 100~110%(440~484V) Frequency set Low : 50~60㎐, High : 60~70㎐ Operating time 200ms app Contact Reset Temperature Vibration Shock Weight Dimension 96 3-Phase Voltage and Frequency Relay DEESYS TOTAL PRODUCTS GUIDE AC110V 10A 0.5sec(cos∅=1.0) Auto Reset Operating temperature -10~55℃ RH < 95% Storage temperature -20~+70℃ Vibration frequency:16.7㎐ Double amplitude:0.4㎜ Direction:horizontal, vertical, transverse Shock acceleration:50G Shock application direction:horizontal, vertical, transverse Shock times : 3 times 1.0㎏ Connection diagram 선박용 3-Phase Phase Fail Relay DFR-021 특징 3상에 흐르는 부하전류를 검출하여 정상상태에서 불평형 및 결상상태가 될 시 즉시 정밀차단하여 모터의 소손을 미연에 방지, 보호하는 계전기로 전류검출 컨버터를 조합하여 사용하는 결상계전기 입니다. Specification Part Name Style Type Connection Input Aux. Power Aux. Power burden Current set range Operating time Accuracy Contact Temperature Vibration Shock Weight Dimension 3-Phase Phase Fall Relay 매입형(Flush mounted type) DFR-021 외부 CT사용, Current converter(MCT와 조합사용) CT : AC5A(2차), Burden : 0.3VA Voltage : AC110V, AC220V, Frequency : 50/60㎐ 7VA AC 1~80 or 64~160A (1’ ry current of MCT 3∅) Less than 4sec ±10% AC 110V 5A 30min (cos∅=1.0) Operating temperature -10~60℃ RH < 95% Storage temperature -20~+70℃ Vibration frequency:16.7㎐ Double amplitude:0.4㎜ Direction:horizontal, vertical, transverse Shock acceleration:50G Shock application direction:horizontal, vertical, transverse Shock times : 3 times 0.5㎏ Connection diagram Equipment Rated Curr. 1~2.5 2~5 4~10 8~20 16~40 32~80 64~160 MCT SelectionMCT Model Tap(A) 20 MCT-31 MCT-32 40 80 160 P.F.R 1’ry turns 8 4 2 1 1 1 1 dial set. 0.25 0.5 1 2 4 8 16 DEESYS TOTAL PRODUCTS GUIDE 97 선박용 3-Phase Phase Sequence Indicator DPS-011 Feature 3상의 상위상을 감지하는 표시기로 3상위상이 정상이면 녹색(Green) Lamp가 점등 되고 위상이 바뀌면 적색(Red) Lamp가 점등되어 정상 상태의 위상을 판별하는 표시기입니다. Specification Part Name Style 매입형(Flush mounted type) Type DPS-011 Connection Input Aux. Power 외부VT 또는 Direct 사용 AC110/190/220/380/440V Burden:3VA(Aux.포함)±10% Voltage : AC110~600V(입력 정격전압과 동시사용) Frequency :50/60㎐ Normal Green LED : R�S�T, S�T�R, T�R�S Reverse Red LED : S�R�T, T�S�R, R�T�S Temperature Vibration Shock Weight Dimension 98 3-Phase Phase Sequence Indicator (Relay겸용) DEESYS TOTAL PRODUCTS GUIDE Operating temperature -10 ~ 55℃ RH < 95% Storage temperature -20 ~ + 70℃ Vibration frequency:16.7㎐ Double amplitude:0.4㎜ Direction:horizontal, vertical, transverse Shock acceleration:50G Shock application direction:horizontal, vertical, transverse Shock times:3 times 0.5㎏ Connection diagram 선박용 Single or 3-Phase Synchroscope DVF-011 Operation/Starting Rotation O㎐<S㎐ � (LED) O㎐>S㎐ � (LED) Feature 본 Meter는 processor를 이용하여 Starting Generator의 주파수를 자동 판별하여 동작하며 Starting Generator의 위상에 대하여 정확한 동작이 이루어집니다. Starting Generator의 주파수가 Operating Generator 주파수보다 ±3Hz를 벗어난 범위에서는 지침(Lamp)이 빠르게 회전합니다. Metor의 지침(Lamp)이 움직이기 시작하는 주파수 범위는 Operating Generator의 정격 주파수의 ±3Hz 이내에야 합니다. Operating Generator의 주파수보다 대기중인 Starting Generator의 주파수가 높을 경우 지침(Lamp)은 SLOW 방향으로 회전하고 Operating Generator의 주파수보다 Starting Generator의 주파수가 높으면 지침 (Lamp)은 FAST 방향으로 회전합니다. Starting Generator와 Bus의 주파수 및 위상이 같게 되면 지침 (Lamp)의 위치는 Meter 위 부분의 Marking지점(lamp)에 위치 하게 되는 상 동기 검출기입니다. Specification Part Name Synchroscop Type DVF-011 Style 매입형(Flush mounted type) Type DVF-011 Connection Input Temperature Vibration Shock Weight Dimension 외부VT 또는 Direct 사용 AC110V±20% Burden : 6VA(Aux. power 포함) Operating temperature -10 ~ 55℃ RH < 95% Storage temperature -20 ~ + 70℃ Vibration frequency:16.7㎐ Double amplitude:0.4㎜ Direction:horizontal, vertical, transverse Shock acceleration:50G Shock application direction:horizontal, vertical, transverse Shock times:3 times 0.5㎏ Connection diagram DEESYS TOTAL PRODUCTS GUIDE 99 선박용 Dimension Dimension DFV-011 DFR-021 DPS-011 DVF-011 100 DEESYS TOTAL PRODUCTS GUIDE 국가형식검정품(한국소방검정공사) Digital Earth Leakage Detector and Relay ▶ Multi Function Digital Earth Leakage Detector and Relay[ELD, ELR] ▶ Analog/Micom Earth Leakage Detector and Relay[ELD, ELR] ELD 누전경보기(Digital, Analog, MICOM) D2K-ED Series Earth Leakage Detector & Relay Feature 누전경보기설치대상물 ● 소방법 시행령 제 24조 2항, 3항에 의거 누전으로인한 화재 및 재해발생예방에 경보기를 설치해야할 소방대상물 대상면적 (㎡) 대상전력용량(A) 연면적 500㎡이상 설치(업무시설, 통신촬영시설, 교육연구시설 및 전시시설의 경우에는 1,000㎡이상) 하여야 한다. 계약전류용량(동일건축물에 계약종별이 다른 전기가 공급되는 경우 에는 그중 최대 계약전류 용량을 말한다)이 100A를 초과하는 경우 에는 설치 하여야 한다. ※500㎡이하 및 100A 이하의 곶에도 설치하여 누전으로 인한 재해방지를 하는것이 좋습니다. System and Protection 교류600V미만의 교류 전원에서의 전기설비 절연불량으로 인한 누전을 영상 변류기를 통하여 동작하는 다기능 다회로의 누전으로인한 화재발생 예방 누전경보 시스템이다. 입력의 신호중에 혼입된 각종 Noise 및 고조파를 Analog Filter 및 Digital Filter를 통하여 정상적인 신호로 변환하여 판독하므 로 정밀한 동작을 구현한다. 또한 16Bit Micro Processor를 이용하여 고속처리 및 RS-485통신기능을 부가하여 원격에서 계전기를 제어 감시할 수 있다. 1대의 누전경보 및 계전기로 8회로, 16회로, 24회로, 32회로까지 감시 및 보호할 수 있다. 기본형은 8회로로 구성되며 8회로를 내장된 별도의 Module 을 이용하면 최대 32회로까지 연결시킬 수 있다. 8회로는 기존의 경보기제품과 동일한 Case에 내장되어 호환이 가능하며 16회로, 24회로 및 32회로 는 19inch Rack의 2/3 크기의 Case를 사용한다. 누전경보 동작시 년/월/일/시/분/초 단위까지 기억되므로 사고 발생시 경보기에서 사고의 순서를 10 개 까지 확인 할 수 있어 누전으로 인한 화재감시등의 평가 수단으로 이용될 수 있다. Display Mode 각 회로의 현재 시점을 기준으로 하여 누전 상태를 실시간으로 LCD(Liquid Cristal Display)표시창에 Scrolling 하며 감시한다. Fault Memory 사고 Data의 횟수는 10회까지 Memory 한다. - Fault Date - Fault Time - Fault Feeder - Fault Current Operating Current and time setting 고감도의 누전부터 대전류의 누전까지 정정할 수 있도록 광범위한 누전전류 Tap을 구비하고 있고, 순간 누전상태 및 동작지연 시간을 적절하게 보호협조 할 수 있도록 Time Delay 기능을 구비하고 있다. Communication and Monitoring 원격에서 계전기를 제어 감시할 수 있도록 RS-485 Port를 적용한 통신기 능이 내장되어 있다. - 사고 전류의 확인 - 동작전류, Time Delay의 설정 - 현재 흐르는 누전 및 지락 전류량 확인 - 사고시의 날짜 및 시간 확인 - Buzzer On / Off 기능 - 수동 자동 설정 가능 102 DEESYS TOTAL PRODUCTS GUIDE D2K-ED Series Earth Leakage Detector & Relay Typical substation architecture Eather-net (TCP/IP) Communication for Specification 통신사양 - 통신속도 : 19,200bps - 통신거리 : 1.2km - 통신방식 : RS-485(2wire) - 최대노드수 : 1~16대 Fault event - current : 8ch, 16ch, 24ch, 32ch - data : date, time, circuit DEESYS TOTAL PRODUCTS GUIDE 103 D2K-ED Series Earth Leakage Detector & Relay D2K-ED08(8circuit) D2K-ED24(24circuit) D2K-ED16(16circuit) D2K-ED32(32circuit) Product name Model Certificate No. Monitoring Circuit Power Source Rated Current Sensitivity Time Setting Range/Deviation Operating Current Non-Operating Current Rated current Z.C.T Contact Display Key Method Earth Leakage Detector [ELD] D2K-ED08 D2K-ED16 07-13 8Circuit D2K-ED24 D2K-ED32 07-16 07-14 07-10 16ircuit 24ircuit 32ircuit AC 110/220 ± 15%, 50/60㎐ (Default), DC 110/125 ± 20% AC 200mA~1000A (100mA Step), Default-0.5A 0.1�3.0Sec/0.1:±50ms, 0.2~3.0:±15%(0.1sec, Step), Default-0.2Sec Between 53% and 75% of resonable value Below 52% of reasonable value 200mA / 100mV(75~125mV at 2㎘ Resistance) 1a(All circuit) 1a(All circuit) 16a(ED16) 24a(ED24) 8a(ED08) 32a(ED32) L.C.D(20Char, X 4Line) MODE,ESC,ENTER,Direction Keys(�,�,�,�) RUN(green) : C.P.U.Error 동작상태감시 AUTO(yellow) : 동작 후 Relay 및 Lamp의 복귀 [On(Flickering) : Auto / Off : Manual] BUZZER(yellow) : 동작시 buzzer 울림[OFF(Flicker)시 꺼짐 / On : 올림] LED(Lamp) COMM(yellow) : 깜박일때 신호 출력 중 ZCT(red) : Faulty ZCT 연결 불량 및 연결이 되지 않았을 경우 PICK(red) : Pick-up 누전전류 동작시 점등 SYS(red) : 내부회로 및 소자 불량시 점등(System Error) ALARM(red) : 누전에 의한 동작 표기시 Fault Memory Resetting Method Temperature Mounting Method Capacity of contact Point Buzzer Insulation Resistance 최고사고치 10회 Memory 가능 및 사고선로별 회로 표시 “1” ( 이 가장 최근 사고를 표시함) Auto Reset/Manual Reset가능(program에 의하여 선택 방법) `-10�60℃(in operation), -20�70℃(to be kept) Flush Mounted Type AC 250A 5A 0.5sec(L/R=0) 75dB(within 1m) 1’ st-ground / 2’ nd-ground / 1’ st-2nd : 100㏁ or more DC500V Megger 1’ st-ground : AC 1,500V Withstand voltage 2’ nd-ground : AC 500V 1’ st-2’ nd : AC 1,500V Lighting impulse Withstand voltage Vibration Aux. power - ground 1.2㎲×50㎲×6㎸ Positive/Negative electronics. 3time Vibration frequency:16.7㎐ Double amplitude : 0.4㎜ Direction:horizontal, vertical, transverse Shock acceleration:50G Shock application direction:horizontal, vertical, transverse Shock Weight 104 DEESYS TOTAL PRODUCTS GUIDE Shock times : 3 times 2kg 7kg D2K-ED Series Earth Leakage Detector & Relay Front View LED indicator CPU(RUN)Error check Auto/Manual Set Buzzer On/Off Set Communication con. ZCT connection check Pick-up/system check Display General Setting Level Setting point Fault check Communication Self test mode Key part Up↔Down menu Right↔Left menu Key Part Top menu modekey Escape Key menu Cursor menu key Reset Lamp and CPU reset Menu Specification Start on display - 제어전원이 인가되거나 “CPU Reset” Key를 누르면 Back Light와 함께 아래의 Logo 화면이 5초정도 Display된 후 다음 상태인 Display On / Off Mode나 상태 Display Mode로 자동 이동된다. - Default : Display On Mode D 2 K - E D D E E s y s S e r i e s V 1 . 0 0 Display On Mode - 다음의 Display 값이 5초 정도 지속된 후 다음 Mode(상태 Display Mode)로 자동 이동한다. D i s p l a y 2 0 0 0 0 1 O n 0 1 M o d e a u l t D C u r r 3 0 . 7 2 9 1 . 6 3 F 0 0 0 d 1 2 3 0 0 0 S . . . C 2 1 4 5 2 7 0 0 0 S . . . T 3 2 7 s s s C 0 0 0 u . . . r 2 1 7 r 0 0 2 F Top menu - 상태 Display Mode에서“MODE”Key를 누르면 다음과 같이 Top Menu가 Display 된다. 10초 이내에 아무런 Key 입력이 없으면 상태 Display Mode로 전환된다. 1 2 : 1 5 : 3 6 Fault가 발생된 경우 - Display On / Off Mode에 관계없이 Fault 발생시에는 다음과 같이 Display 한다. - Fault Memory창으로 이동하며 최대 10회까지 저장된다. -“Esc”Key를 누르면 상태 Display Mode로 됨 F F 0 ㅁ0 Display Mode - Fd(Feeder) : 감시회로 - SC : Set Current - ST : Set Time(Delay) - Curr(Current) : 현재 누전량 표시 - F(Fault 상태) : 누전 동작을 표시한다. (×표시) - 상기 상태는 Scrolling하고 있으며 Up/Down 방향 Key(↑,↓)를 1회 누를 때마다 1Line씩 이동된다. D a t e 0 1 0 7 0 1 0 7 T 1 . G e 2 . L e ㅁ3 . F a T n v u O e e l P M E N U r a l S e t l S e t t C h e c k � T i m e 1 7 : 3 6 1 7 : 3 6 DEESYS TOTAL PRODUCTS GUIDE 105 D2K-ED Series Earth Leakage Detector & Relay Sub Menu General Set Display On / Off Mode 설정, Buzzer On / Off 설정, Reset Auto / Manual 설정 / Memory Erase/ Date / Time Set Level Set 동작 전류 및 Delay Time 설정 Fault Check 누전 발생시 Fault 확인 (누전된 Feeder, 누전 전류, 누전 발생 시 간) Communication 통신에 관계된 항목의 설정 Test 자체동작 시험에 관한 항복 설정 System Menu 106 DEESYS TOTAL PRODUCTS GUIDE D2K-ED Series Earth Leakage Detector & Relay ● General Set ∙Top Menu에서 1. General Set에 Cursor를 위치한 후 Enter를 누르면 다음과 같이 Display 한다. G 1 . D i 2 . B u ㅁ3 . R e e s z s n p z e e r a l S l a y [ O e r [ O t S e t e n n [ t ] ] A u t o ] � ● Memory Erase [Yes / No] ∙Memory Erase에 위치한 Enter를 누르면 Memory를 지운다. ∙정정값이 Save 되면 전 단계 Sub Menu로 이동된다. M e m o r y E r a s e Y E S : U P [ N ] N O : D O W N ∙Display Time의 변경이 없는 경우는 Enter key를 누르고, 변경 시에는 이어서 동일한 절차에 의하여 설정한 후 Enter Key를 누 르면 다음과 같이 Display 된다. C u r r e n t S e t [ 0 . 5 ] A D e l a y T i m e [ 0 . 2 ] s A r e Y o u S u r e . ? ( Y ) Y E S : U P N O : D O W N ∙변경후 Enter Key를 누르면“Are you Sure( )” 라는 Message 가 나타난다. Up / Down Key를 눌러 Y를 입력한 후 Enter Key를 누르면 변경된 값이 입력된다. ∙정정값이 Save 되면 Top Menu로 이동된다. ● Communication ∙Top Menu에서 4. Comm set에 Cursor를 위치한 후 Enter를 누르면 다음과 같이 Display 한다. ●“Each” 로 개별 설정할 경우 S 0 0 ㅁ0 E T M O 1 A [ 0 . 2 A [ 0 . 3 A [ 0 . D 5 5 5 E ] ] ] ( I D D D / t t t d [ [ [ t 0 0 0 ) . 2 ] . 2 ] . 2 ] C O M M 1 . P o r t 2 . B a u d ㅁ3 . P a r i t � ∙각가의 Feeder에 누전 및 지락 전류를 Up/Down 방향 Key를 이용하여 입력하고 Dt는 Mode Key를 입력하고 Up/Down 방향 Key를 이용하여 값을 설정한다. Display된 Feeder의 정정을 완 료하면 마지막 Line 끝에 Cursor를 위치한 후 좌측 방향 Key를 눌러 Feeder가 Scroll 되도록 하여 Setting을 한다. ∙같은 방법으로 각 Feeder를 입력한 후 Enter Key를 누르면 다 음과 같이 Display 된다. S E T M O D E A r e Y o u S u r e . ? ( Y ) \ Y E S : U P N O : D O W N S E T N o . r a t e y M O D E [ 0 0 ] � [ 1 9 2 0 0 ] [ E v e n ] ● Port No C o m m ( P o r t N o . [ 0 1 ] 1 1 6 ) H I : U P L O W : D O W N ∙Up / Down 방향 Key를 누르면 Come Port를 설정할 수 있습 니다. ∙Port 값이 Save 되면 위 Sub Menu로 이동한다. ( I / d t ) ∙Are You Sure?라는 message가 나타나면 Y를 입력하고 Enter 를 눌러 정정값을 모두 변경한다. ∙변경하고자 하는 Feeder가 1개면 해당 Feeder의 정정값을 변경 후 Enter를 누르면 변경된다. ∙정정값이 Save 되면 Top Menu로 이동된다. ∙Default: <Fault Current : 0.5A / Time Delay : 0.2Sec> ●“ALL” 로 일괄 설정할 경우 C u r r e n t S e t [ 0 . 5 ] A D e l a y T i m e [ 0 . 2 ] s H I : U P L O W : D O W N ● Baud rate ∙19,200bps로 고정되어 있습니다. ● Stop Bit 설정 ∙1로 고정되어 있습니다. ● Test ∙Top Menu에서 5. Test Set에 Cursor를 위치한 후 Enter Key 를 누르면 아래와 같이 Display 한다. T o p 3 . F a u l t 4 . C o m m S ㅁ5 . T e s t S M C e e e n u h e c k t t ∙모든 Feeder의 Test가 끝나면 Esc Key를 입력하면 Top Menu 로 이동한다. ∙일괄 설정으로 하여 Enter Key를 누르면 다음과 같이 Display된다. ∙Current Set에서 Up / Down 방향 Key를 이용하여 설정한다. DEESYS TOTAL PRODUCTS GUIDE 107 D2K-ED Series Earth Leakage Detector & Relay Wiring �8C External Wiring(ED 8 CIRCUIT TYPE) T1~T8 : “a” 접점 Tcom : Common 접점 PP PN : AC 110/220V(DC110V)Aux, Power Ta Tb Tc : 일괄 Alarm 접점 E : 외함 접지단자(E3) Z1~Z8 : ZCT 각회로 단자(각회로와 동일함) Zcom : ZCT 공통단자 ABG : 통신(RS-485)단자 DA: (+), DB(-), DG(통신접지), 통신용접지는 외함 접지단자와 분리하십시요. Wiring T1~T32 : “a” 접점(각회로와 동일함) Tcom : Common 접점 PP PN : AC 110/220V(DC110V)Aux, Power Ta Tb Tc : 일괄 Alarm 접점 E : 외함 접지단자(E3) Z1~Z32 : ZCT 각회로 단자 Zcom : ZCT 공통단자 ABG : 통신(RS-485)단자 DA: (+), DB(-), G(통신접지), 통신용접지는 외함 접지단자와 분리하십시요. 108 DEESYS TOTAL PRODUCTS GUIDE D2K-ED Series Earth Leakage Detector & Relay Terminal arrangement �8C, 16C, 24C, 32C Dimension �8C � 16C, 24C, 32C DEESYS TOTAL PRODUCTS GUIDE 109 한국검정공사 형식승인품 전자기 적합성 시험필 Earth Leakage and Ground Fault Relay ■Multi Function Earth Leakage Detector and Fire Alarm ■Earth Leakage Fire Alarm and Relay [ELR] 1C, 5C, 10C ■Earth Leakage Relay [ELR] 1C ■Multi Function Ground Relay [GFR] 5C, 10C ■Aux Relay Board [Isolation] 5C, 10C ■Ground Fault Relay 1C 누전경보기 지락검출계전기 (Analog/MICOM) (Analog/MICOM) DEESYS TOTAL PRODUCTS GUIDE 111 Multi Function Earth Leakage Detector & Fire Alarm 누전경보기를 설치행야 할 시설물(소방법 제 29조 3항) 누전경보기를 설치해야 할 소방 대상물(내화구조가 아닌 건축물로서 벽∙바닥 또는 반자의 전부나 일부를 불연재료 또는 준불연재료가 아닌 재료에 철 망을 넣어 만든것에 한한다)은 다음과 같다. 다만 가스시설 또는 지하구의 경우에는 그러하지 아니하다.(개정 94.7.20, 97.9.27) 연면적 500㎡∙이상(업무시설∙통신촬영시설 교육연구시설 및 전시시설의 경우에는 1,000㎡이상)인 것(개정 94.7.20) 계약전류용량(동일 건축물에 계약종변이 다른 전기가 공급되는 경우에는 그중 최대계약전류 용량을 말한다)이 100암페어를 초과하는 것 Facilities requiring installation of leakage detection and fire alarm devices: <As per the enforcement laws articles 17-8, 18-6, and 19-7 of the laws for prevention and extinguishing of fires> Objective facilites Aggregated area Contract current capacity -Hotels, Motels 300㎡ or more Above 100A -Dorm Inatories All lines below same as above All lines below same as above 500㎡ or more Above 100A All lines below same as above All lines below same as above 100㎡ or more Above 100A All lines below same as above All lines below same as above Class Ⅰ facilities per article 17-8 -Theaters, Stadiums -Conference halls, Restautrants -Public markets, Supermarkets -Hospitals -Welfare institution for the seniors -Welfare institution for the handicapped -Kindergartens -Bathhouseds Class Ⅱ facilities per article 18-6 -Rail stations & Bus terminals -Passenger’ s waiting rooms -Churches & Temples -Multi-family housings of 4 stories and up -Schools -Exhibition halls -Factories and Work places Class Ⅲ facilities per article 19.7 -Warehouses -Garages -Hangars 112 DEESYS TOTAL PRODUCTS GUIDE Multi Function Earth Leakage Detector & Fire Alarm [ELD] Optional Specification (For example) ∙DED-M10 : Set MICOM type ELD 10 circuit ∙DED-A05 : Set ANALOG type ELD 5 circuit DE D 05 : 5 circuit Set type 10 : 10 circuit Set type D : General Alarm Purpose R : Relay(Trip) M : Micom A : Analog Rating and Performancea Description Model No Type approval No Rated supply voltage Rated supply frequency Nominal operating current Current Micom type Analog type DED-M10(10C) DED-M05(5C) DED-A10(10C) DED-A05(5C) 07-4 07-5 07-17 07-12 AC:110/220V in common 50/60㎐ 0.2~0.5~1.0A(3 steps) ZCT Input:200㎃/100㎷ Operating 53%~75% of nominal operating current 1sec 이내 Non operating 52% nominal operating current Allowable supply voltage fluctuation Reset Method Warning circuit voltage 80%~120% of rated supply voltage Manual/Automatic Below AC 600V Leakage level:Digital LED indication Leaking circuit: RED LED Leaking circuit: RED LED Warning:RED LED Warning:RED LED Power supply:GREEN LED Power supply:GREEN LED ZCT continuity:YELLOW LED ZCT continuity:YELLOW LED Cont/Auto-alarm:YELLOW LED Cont/Auto-alarm:YELLOW LED Buzzer alarm:YELLOW LED Buzzer alarm:YELLOW LED Power consumption 3.5VA 3.0VA 8VA 6VA Operating 6.0VA 5.5VA 9VA 7VA Ambient temperature Sound level -10℃(Thru + 50℃) Buzzer(more than 75dB) Primary-case Insulation resistance Secondary-case 100㏁ or more (Tested by 500V megger) Primary-Secondary Primary-case:1500V Dielectric strength Secondary-case 500V AC 60㎐, 1Min Primary-Secondary:1500V Impluse wave withstand voltage Vibration strength Mechanical shock resistance Contact point capacity Duration of wave tail:30~50㎳ and up On duty:Full wave width 1㎜, 1000rpm, 10min Not on duty:Full width 4㎜, 1000rpm, 60min On duty:Natural drop 15 times Not on duty:Accelebration of 5㎏ Max force in any direction for 5 times 1a:AC 250V,0.5A or DC 30V, 2A / contact Fuse rating Weight Peak value:6.0㎸, Duration of wave front:0.5~1.5㎳ Between terminals Power supply terminals to case 0.1A 1.9㎏ 0.2A 1.7㎏ 2㎏ 1.9㎏ Casing ABS Resin/Black N1.5 Mounting method Flush mounting DEESYS TOTAL PRODUCTS GUIDE 113 Multi Function Earth Leakage Detector & Fire Alarm [MICOM] DED-M10 특징 Features 1. 집합형 누전 경보기는 다회로의 누전을 동시에 감지하여 경보 또는 차단기를 Trip시키는 기능으로 구성되어 있습니다. 2. MCU (A/D converter)내장을 주회로에 장착하여 선로 점검에 필 요한 기능을 디지털로 표지하여 주는 다기능 누전 경보기입니다. 3. 고장 선로 및 누전 전류량을 연산하여 DISPLAY 에 표시, 확인할 수 있고, 복구 조치에도 용이 합니다. 4. 자기 감시 기능을 수용하여 동작에 안정성을 기하였으며 다양한 LED 표시 기능으로 수신기의 동작 상태를 쉽게 판별할 수 있습니 다. 5. 자체 시험 스위치 및 도통 스위치를 사용하며 자체적으로 내부회로 를 검사할 수 있습니다. 1. Multi type earth leakage detector has alarm or CB trip function with detecting multi circuit leakage. 2. As equipped with MCU(A/D converter) at main circuit, it is multi function earth leakage alarm unit with digital display for detection circuit. 3. Available to check leakage current armount and leakage lines. 4. As equipped with self detecting system, easy to check operation condition stably with various LED indication function. 5. Self detecting and checking system make it be easy to inspect internal circuit. Front plate 1. Leaking line number indicator 2. Leaking level indicator(mA) 3. Line current check 4. Self-test button(switch) 5. Leaking circuit indicator lamp 6. Sensitivity selector switch 7. ZCT continuity indicator lamp 8. ZCT continuity test button(switch) 9. Cont/Auto warning lamp 10. Cont/Auto selector switch 11. Buzzer on/off warning lamp 12. Buzzer on/off switch 13. Reset switch 14. Power supply indicator lamp 15. Warning lamp 114 DEESYS TOTAL PRODUCTS GUIDE Multi Function Earth Leakage Detector & Fire Alarm [MICOM] 기능별 명칭 및 설명 1. 누전회로 표시부 누전이 발생한 선로를 숫자로 표시합니다. 2. 누전량 표시부 누전이 발생한 선로의 누전량을“mA”단위로 표시합니다. 3. 회로검사 스위치 (TACT) 회로검사 스위치를 1회 누를때마다 한 선로씩 회로 표시와 누전 량이 해당 표시부(①,②)에 표시됩니다. 4.자체시험 스위치(TACT) 누전 경보기의 모든 기능을 일괄적으로 검사하는 스위치로 누전 회로 표시부, 누전량 표시부, 회로별 누전 표시등, 지속/자동 주의 등, 경보등, 부져 주의등을 점등하여 각 기능의 이상유무를 확인 합니다. 5. 회로별 누전 표시등(적색 LED) 누전 발생시나 자체 시험 스위치를 눌렀을 경우 또는 도통 스위 치를 눌렀을 경우 해당 회로의 표시등이 점등 됩니다. 6. 감도 설정스위치 0.2/0.5/1.0A의 탭중 설정된 값 이상의 누전이 발생시 경보 또는 트립 시킵니다. 7. ZCT 도통 표시등(황색 LED) 8. ZCT 도통 스위치(PUSH) 변류기가 수신부의 각 회로 단자에 정상적으로 연결되었을 경우, 도통 스위치를 누르면 해당 회선의 도통 표시등이 점등되고 실제 누전과 동일한 시험기능입니다. 9. 지속/자동 스위치 주의등(황색 LED) 10. 지속/ 자동 선택 스위치 지속/자동 스위치를 자동으로 설정하였을 경우에는 지속/ 자동 스위치 주의등이 점멸하여 스위치 상태가 자동에 설정되어 있는 것을 경고합니다. 11. 부져 ON/OFF 주의등(황색 LED) 12. 부져 ON / OFF 선택 스위치 부져 ON / OFF 스위치는 OFF로 설정하였을 경우에는 부져 ON/OFF 주의 등이 점멸하여 스위치 상태가 OFF에 설정되어 있 는 것을 경고합니다. 13. 복귀(Reset)스위치 수신부의 전 기능을 초기 감시 상태로 환원 시키는 스위치입니 다. 14. 전원등(녹색 LED) 전원전압 (AC 110/220V)이 정상적으로 공급될 때 점등됩니다. 15. 경보등(적색 LED) 누전 발생시 또는 회로 시험시 점등됩니다. Component Parts and Functions 1. Leaking circuit indicator It indicator leakage fault circuit number on LED. 7. ZCT continuity indicator lamp(Yellow LED) It lights to indicate continuity. 2. Leakage level indicator It indicates the level of leakage in mA unit. 8. ZCT continuity switch(Push button type) If the switch is pressed on condition that current transformer is connected to applicable line terminals of the receiving part, the continuity lamp of the line turns on enabling to perform leakage test in simulated circumstance of real leakage. 3. Circuit test button(Tact type) At each time button<or switch>is pushed. circuit is newly selected one by one with the indication of circuit number and level of leakage. It is convenient to check levels of leakages of each line though it happens in plural number of circuits at a time. 4. Self-test switch(Tact type) It is used to check as a whole any abnormality in performance of every functional components like leaking circuit indicator, leakage level indicator, leakage fault line indicator lamps, cont./auto warning lamp, alarm lamp and buzzer warning lamp. 5. Leakage fault indicator lamp by line<Red LED> In case to leakage fault, the lamp of subject line turns on uncondition of continuity button(or switch) is pressed or self-test switch is pressed. 6. Sensitivity selector switch Sensitivity is adjusted by the switch to an one among three steps of 0.2./0.5/1.0A as appropriate to specific line. 9. Continue/Auto warning lamp(Yellow LED) 10. Continue/Auto selector switch If Auto, position is selected by Cont/Auto switch, the continue/Auto selection warning lamp blinks to call attention on the setting. 11. Buzzer on/off warning lamp(Yellow LED) 12. Buzzer on/off selector switch If the switch is set to off, the buzzer on/off warning lamp blinks to warn the selected switch position. 13. Reset switch If pressed, it activates entire receiver function to initial status. 14. Power supply indicator lamp(Green LED) It turns on only when power(AC110-220)(AC240V) is supplied normally. 15. Alarm lamp(Red LED) It lights in case of leakage occurrence and testing. DEESYS TOTAL PRODUCTS GUIDE 115 Multi Function Earth Leakage Detector & Fire Alarm [MICOM] 동작 특성 설명 1. 집합형 누전경보기는 여러 회로를 집합하여, 동시에 감시하며 전 원장치 및 경보장치를 1조로 하여 구성된 경보기입니다. 2. MCU의 선로 감시 명령에 의해 모든 경계선로를 동시에 감시 합 니다. 3. 경계 선로에 누전이 발생하면 경계 선로에 설치한 영상 변류기에 서 전압이 출력되어 수신부의 누전검출 회로에 입력됩니다. 4. 입력 전압은 증폭되어진후, 중앙처리장치에 입력됩니다. 5. 중앙처리장치(MCU)는 증폭된 입력전압을 A/D로 변환하고 감도 설정된 기준값과 비교한 후 일정 비율 이상이 되면 다음과 같이 경보 표시합니다. ① 경보등(적색LED)의 해당 회로가 점등됩니다. ② 부져를 동작시켜 경보합니다. ③ 회로별 누전표시등(적색LED)의 해당 회로가 점등됩니다. ④ 누전 회로 표시 디지털에 누전회로가 숫자로 표시됩니다. ⑤ 누전량 표시 디지털에 누전회로의 누전량이 (mA)단위로 표시 됩니다. (주의) 지속/자동 스위치를 자동으로 설정하였을 경우 지속/ 자동 스위치 주의등(황색 LED)이 점멸하고, 누전량이 없어졌 을 경우 자동적으로 모든 경보표시가 소멸됩니다. (주의) 부져 On/Off 스위치를 Off로 설정하였을 경우부터 On/Off 주의등(황색 LED)이 점멸하고 기준치 이상의 누전이 발생하여도 경보음은 울리지 않습니다. 6. 표시확인 두 개 이상의 선로에 누전이 발생하였을 경우, 회로별 누전표시 등은 누전선로를 전부 점등하지만, 누전회로 표시 디지털과 누전 량 표시 디지털에는 가장 먼저 누전이 발생한 선로의 값만 표시 합니다. 다른 선로의 값을 확인하고자 할 때에는 회로검사 스위 치(TACT)를 눌러 각 회로의 누전량을 점검할 수 있습니다. 7. 복귀(RESET) 선로의 누전상태를 보수한후 지속/자동 스위치가 지속으로 설정 되어 있을 경우에는 누전표시가 지속되므로 복귀 스위치를 눌러 수신부의 기능을 환원시켜야 합니다. Performance Features 1. Being a set type leakage detector, it sets and monitors plural number of line circuits simultaneously and features a combination of power supply and alarm system in a unit. 2. According to line monitoring instruction from MCU, it monitors all lines hooked simultaneously. 3. In case leakage is developed in any monitored line, the residual current transformer generates voltage which is fed to the leakage detection circuit of receiver as an input. 4. The input is amplified and then fed to MCU for processing. 5. At MCU, amplified input is converted by A/D converter for comparison against the voltage one of selected sensitivity. And if a ratio higher than predetermined value is obtained, warnings become activated as follows ; 1) Alarm lamp(Red LED) turns on. 2) Buzzer-alarm. 3) Leakage fault line indicator lamp(Red LED) of subject line turns on. 4) Leaking line number is circuit indicator. Internal block diagram 116 DEESYS TOTAL PRODUCTS GUIDE 5) Leakage level indicator displays lever of leakage in mA nuit. Note 1 : When Cont/Auto switch is set to auto. position, warning lamp(Yellow LED) will blink and when the leakage stops, all warnings and alarm will be canceled. Note 2 : When buzzer on/off switch is set to off position, warning lamp(Yellow LED)will blink and will not alarm if the leakage exceeds the critereon. 6. Clarification of warning indications in case two or more lines is leaking concurrently, the leaking line indicator lamps of such line will all light concorrently, but the leaking line number indicator and leaking level indicator will display the value of first detected line only. Leaking level of other lines can be checked by pressing the line test switch(Tact type). 7. Reset if Cont/Auto switch remains after the leakage is removed, reset to cont, position. Multi Function Earth Leakage Detector & Fire Alarm [MICOM] 설치전 점검 사항 경보기를 설치하기전 다음 사항을 점검하여, 경보기의 기능을 확인 하시기 바랍니다. 1. 수신부의 P0, P1 단자에 전원 전압(AC220V)을 연결하십시오. 만 약 AC 110V를 사용하실 경우 뒷면의 슬라이드 스위치를 AC 110V로 전환 조정하여 사용하십시오. 2. 전원을 연결한 후, 뒷면의 On/Off 스위치를 On으로 설정하면 전 원 투입상태 (전원 LED 점등)가 됩니다. 3. 회로검사 스위치(TACT)를 눌러 디지털 표시를 점검합니다. 스위 치를 누를 때마다 누전 회로 표시가 1회로씩 순차적으로 변환되 고 누전량은 000 을 표시합니다. 스위치를 누르지 않고 약 5 초가 경과하면 자동으로 표시가 소멸됩니다. 5. 다음은 회로시험 및 ZCT 도통 스위치를 회로별로 눌러 회로 시 험을 합니다. 각 회로별 스위치를 누르면 회로별 누전표시 LED 와 경보 LED가 점등되고 누전회로 표시 디지탈에는 해당회로, 누전량 표시 디지탈에는 999 를 표시합니다. 개별 시험 후 복 귀 S/W를 눌러 초기상태 복구시키십시오. 6. 지속/자동 S/W를 자동(LED 점멸상태), 부져 On/Off S/W를 Off(LED 점멸상태)로 설정하고 5항의 시험을 행하십시오. 이때 부져는 울리지 않고 모든 표시 장치는 자동으로 환원됩니다. (주의 : ZCT 도통 LED(황색)는 회로별 단자에 ZCT를 접속한 후 도통 스위치를 눌러야 점등합니다.) 7. 이상의 시험이 끝나면 On/Off를 Off로 한 후 전원을 제거하십시오. 4. 자체시험 스위치를 눌러 수신부의 내부회로를 점검합니다. 스위 치를 누르면 도통 LED(황색)를 제외한 모든 표시장치와 경보장치 가 자동적으로 차례로 동작한 후 초기상태로 환원됩니다. 이때 누 전회로 표시 디지털과 회로별 누전표시 LED는 자동적으로 하나 씩 증가하고 누전량은 888 을 표시하여 디지털 Segment의 이상 유무를 확인합니다. Checking Items Before Installation The following points should be checked before installation to ensure operability. 1. Connect control power(AC 220V) to terminals P0 and P1 of ELD(Note: Since the control power is set to AC220V at factory on delivery, convert slide switch on the back of ELD to AC110V if it is used AC110V for control power) 2. After connecting control power to the terminals, set power on/off switch to "on" position to energize the detector(Red LED turns on). 3. Check digital display of leaking line number indicator and leaking level indicator by pressing line test switch(Tact type). Every time the switch is pressed the line number on display advances to very next higher number in burn and the leakage level indicator will display zeros. After an elapse of about 5 minutes without additional pressing, the indications will disapear automatically. 4. Check intenral circuits by pressing selftest switch. If the switch is pressed, all displays and alarms turn back initial stage automatically one by one except the continuity indicator lamp(Yellow LED) At that times the display of leaking line indicator changes the display sequence by with steps by one at each time when the switch is pressed and leakage level indicator will unchange to show Adn thus check of digital segment is accomplished. 5. Check lines by pressing line test and ZCT continuity switch. When line test switch is pressed, line leakage indicator LED and alarm LED turn on. And leaking line number indicator will display leaking current of subject line number. After checking all items, return in initial stage by pressing the return s/w 6. Repeat checks of paragraph 5. set Cont/Auto switch to Auto. Position(LED blinks) and buzzer on/off switch to off(LED blinks). At this time, the buzzer does not sound and all indicators return to automatically.(Note: ZCT continuity indicator LED (Yellow) will turn on only when ZCT is connected before the continuity test is performed.) 7. After completion of all check ups in preceeding paragraphs, set the power on/off switch to 'off' and take off control power from the terminals. DEESYS TOTAL PRODUCTS GUIDE 117 Multi Function Earth Leakage Detector & Fire Alarm [MICOM] 설치시 점검사항 Checking Items for Installation 1. 설치하고자 하는 장소에 수신기의 치수에 맞게 제작 설치합니다. 2. 경계선로에 ZCT를 선정합니다. 1)부하용량에 맞게 ZCT를 선정합니다. 2)대전류 모선 혹은 강한 자장으로부터 10cm 이상의 위치에 설치 하여 주십시오. 3) 단상,3상 구별없이 부하 선로에 설치합니다. 4) 3상 4선식인 경우도 중성선을 포함 4선을 모두 ZCT에 관통시 킵니다. 3. 수신기 뒷면 단자 결선 1) 변류기측 2개의 단자 중(단자의 극성구별은 없음) 1개는 수신부 각 회로 단자 ①. ②, ③, ④, ⑤, ⑥, ⑦, ⑧, ⑨, ⑩에 결선하고, 1개의 단자는 공통단자로 수신부 ⓩ 공통단자에 연결합니다. 2)단자 Ta,Tc(무전압접점)는 외부에 부져를 설치시 연결합니다. 3)단자(E)는 접지단자로 배전반 그라운드로 연결하십시요. 4. 수신기의 전원은 다른 회로 전원과 병렬로 연결하지 마시고 분기이 전의 별도 전원을 사용해야합니다. 1. Arrange a mounting panel suitable to the receiver and install it on the desired location 2. Install ZCT on lines to monitor. 1) Select ZCT of adequate capacity for each line. 2) install ZCT lotated at 10cm or more distance current bus or strong magnet field 3) Install ZCT on load side whether the power supply is single phase or 3 phase. 4) In case of 3 phase 4 line system. all 4 lines including the neutral should go through the ZCT. 3. Connections to terminals on back of receiver 1) The one terminal of ZCT,s two terminals (not distinction of the polarity) should be connected to line terminals ①, ②, ③, ④, ⑤, ⑥, ⑦, ⑧, ⑨, ,⑩ and the other terminal which is the common shall be to common terminal ⓩ of the receiver. 2) The Terminal Ta and Tc(no voltage contacts) are used when a buzzer is installed on the outside. 3) The terminal E for grounding should be connected to the grounding terminal of distribution board. 4. The control power of receiver should be connected an independent source which is not distributed from main source 설치후 점검사항. Checking Items After Installation 1. 전원등이 점등되었는지 확인합니다. 2. 회로 시험 및 ZCT도통 스위치를 약 1초간 눌러 각 회로별 동작상 태 및 해당회로의 ZCT 도통 LED가 점등되는지 확인합니다. 만약 점등되지 않을 시에는 해당 단자의 연결상태를 점검하시기 바 랍니다. 3. 복귀 스위치를 눌러 수신부의 전기능을 초기감시상태로 환원시킵니 다. 4. 회로 검사 스위치를 눌러 각 회로의 누전량을 확인하시기 바랍니다. 5. 회로에 기준치 이상의 누전이 발생했을 시, 누전회로 표시 디지털과 누전량 표시 디지털에는 최초의 누전 전류값이 표시되고 회로별 누 전 표시등에는 고장 회로가 전부 점등됩니다. 6. 회로의 누전량이 1.0A를 초과할 경우에는 999 를 표시합니다. 1. Check whether the power lamp is turned on or not 2. Press circuit test switch and ZCT continuity switch during about one second and Check whether circuits are in normal status and ZCT continuity indicator lamp turns on. If the lamp do not turn on, please check up the connection of respective terminals. 3. Please Initialize entire receiver function by pressing reset button. 4. Check levels of leakage on each circuit by pressing circuit test switch. 5. In case of a leakage exceeding the criterea, leaking circuit number indicator and leakage level digital indicator will display the first detected leaking circuit number and its level of leakage while leakage fault indicator lamps will indicate leaking lines individually. 6. If the leakage level exceeds 1.0A, the 999 will display on the leakage level indicator. 118 DEESYS TOTAL PRODUCTS GUIDE Multi Function Earth Leakage Detector & Fire Alarm [Analog] DED-A10 동작 특성 설명 Performance Features 전기적 환경에 대한 서지보호 대책으로 전자기 적합성 시험을 필한 제 품으로 어느 환경에서나 사용가능하며 전기적 환경에 대응할수 있는 회로를 추가하여 제작된 제품입니다. 1. In case of leakage, output voltage that is induced in the current transformer is storaged to leakage detection circuit. 2. Receiver adjusts input voltage deriving to leakage to sensitivity scale for comparison with the criterion. And if the value is determined to be exceeding the criterion, it generates warning and alarm as follows. 1) The alarm lamp(Red LED) turns on. 2) The buzzer sound on to sign the fault. Note : If buzzer on/off switch is set to off, position buzzer on/off lamp will blink without sounding. 3) Leaking circuit indicator lamp (Red LED) of the applicable circuit turns on or off. Note : If Continue / Auto switch is set to Auto position, continue / Auto warning lamp will blink. When the leakage is stopped or the circuit is recovered to normal state, the alarms of subparagraphs 1) and 2) will automatically disappear. 3. Reset If Continue / Auto switch is set to continue position, press reset button to initiaize receiver function as soon as the leakage defect is removed. 1. 선로에 누전이 발생하면 해당 선로 변류기의 출력 전압이 누전 검출 회로에 입력되어 집니다. 2. 수신부는 누전 검출 전압을 감도 조정 회로에 의해 재조정한 뒤, 비 교 판정을 하고 기준치 이상이 되면 다음과 같이 경보 표시 합니다. ① 경보등(적색 LED)을 점등합니다. ② 부져를 동작시켜 경보합니다. (주의 : 부져 on/off 스위치를 off로 설정하였을 경우에, 부져 (on/off 주의) 등이 점멸하고 부져는 동작하지 않습니다.) ③회로별 누전 표시등(적색 LED)의 해당 회로가 점등됩니다. (주의 : 지속/자동 스위치를 자동으로 설정하였을 경우에는 지속/ 자동주의 등이 점멸하고, 누전이 복구되거나 없어졌을 때 자동적 으로 위 ①,②항의 경보표시가 소멸됩니다. 3. 복귀(Reset) 선로의 누전상태를 보수한 후 지속/ 자동 스위치가 지속으로 설정 되어 있을 경우에는 복귀 스위치를 눌러 수신부의 기능을 초기 상 태로 환원합니다. Internal block diagram DEESYS TOTAL PRODUCTS GUIDE 119 Multi Function Earth Leakage Detector & Fire Alarm [Analog] 설치전 점검사항 Checking Items Before Installation ※ 경보기를 설치하기전 다음 사항을 점검하여, 경보기의 기능을 확인 하시기 바랍니다. Note : Check following items to ensure normal function of the device before installation 1. 수신부의 P0,P1 단자에 전원 전압(AC 220V)를 연결하고 뒷면의 전 원 on/off 스위치를 on으로 설정하십시요. (경보기의 전원 전압은 공장 출하시 설정치가 AC 220V입니다. 만 약 AC 110V를 사용하실 경우 뒷면의 슬라이드 스위치를 AC 110V 로 전환 조정하여 사용하십시오.) 1. Connect power line (AC 220V) to terminals P0 and P1 of the receiver and set power on/off switch to on position. (The power is set to AC 220V at factory for delivery. If AC 110V is used, set the position of selector switch to AC 110V position.) 2. 전원등 (녹색 LED)이 정상적으로 점등되면, 회로 시험 및 ZCT 도 통 스위치를 회로별로 눌러 회로시험을 합니다. 각 회로별 스위치 를 누르면 회로별 누전 표시 LED와 경보 LED가 점등되고 경보음 이 울립니다. 개별 시험후 복귀 스위치를 눌러 초기상태로 복귀시키 십시요. 2. When power lamp (Green LED) is turned on to indicate normal status, carry out circuit tests by pressing circuit test switch and act continuity switch for each circuit. When circuit test switch of a line is pressed, leakage indicator LED and warning LED of the circuit turn on with alarm. When the test is over, intialize all the funclion by pressing reset button. 3. 2의 시험을 지속/자동 스위치를 자동에, 부져 on/off S/W를 off로 설정하고 재차 행하십시요. 이때 부져는 울리지 않고 모든 표시장치 는 자동으로 환원됩니다. (주의: ZCT 도통 LED는 회로별 단자에 ZCT를 접속한 후 도통 스 위치를 눌러야 점등합니다.) 4. 이상의 시험이 끝나면 뒷면의 on/off 스위치를 off 상태로 전환한후 전원을 제거하십시요. 3. Repeat the testing explained in above paragraph 2 with Cont/Auto switch that is set to Auto position and buzzer on/off switch that is set to off position. In this instance. /and buzzer will not sound and all the indicators will return to normal status automatically. (Note : ZCT continuity LED will light only when ZCT is connected to circuit terminals and continuity test switch is pressed). 4. After the completion of above tests, return the power switch on back panel that is set to off and then remove power connection 설치후 점검 사항. 1. 전원등이 점등되었는지 확인합니다. 2. 회로시험 및 ZCT 도통 스위치를 눌러 각 회로별 동작상태 및 해당 회로의 ZCT도통 LED가 점등되는지 확인합니다. 만약 점등되지 않 을 시에는 해당 단자의 연결상태를 점검하시기 바랍니다. 3. 복귀 스위치를 눌러 수신부의 전기능을 초기감시상태로 환원시킵니 다. 120 DEESYS TOTAL PRODUCTS GUIDE Checking Items After Installation 1. Check whether power supply lamp is turned on or not 2. Press circuit test switch and ZCT continuity switch. And check whether if circuit state indicator lamp and ZCT continuity indicator lamp of the circuit turn on. If no, check connections of terminals. 3. Initialize the performance of receiver by pressing reset button. Multi Function Earth Leakage Detector & Fire Alarm [Analog] External terminal arrangement BZ:BUZZER : AC 110/220 Selection S/W : Power ON/OFF S/W ⓕ:FUSE P , P₁: 110/220V Common 0 Ta Tc : Warning relay contacts(no voltage) 1~10 : ZCT Secondary circuit terminals Z : ZCT Secondary circuit common terminal E : Grounding terminal NC : Idle terminal Leakage detector external wiring 1. In case of 3 phase 4 line power system, go through all 4 lines into ZCT. 2. Control power shall be connected to P0 and P₁for AC 110/220V in common(Check setting of voltage selector switch). 3. Terminal Ta and Tc. (no voltage) is used to connect externally installed buzzer and warning lamps. 4. Terminal Z is common to all circuits. That all common terminals shall be connected to terminal Z. 5. Terminal E is for grounding, It should be connected ground terminal on terminal Z. 6. Use power service outlet for it self alone without tapping. ※ ZCT Common단자는 내부에서 연결이되어 있으므로 한단자만 사용해도 됩니다.(10C만 해당) External dimension(ELD-M10/M05,ELD A10/A05) Cutting Size: 165 X 122mm DEESYS TOTAL PRODUCTS GUIDE 121 Earth Leakage Fire Alarm & Relay [ELR]-1C, 5C, 10C Features Flush mounted type 1. This earth leakage relay have same function with earth leakage detector and is more developed relay that is able to use the external terminal ※How to use the external terminal. 1) control at same time trip equippment and earth indicator & detector at same time. 2) useing for leakage fault indicator of central control board 3) Use timer for delaying the trip time of C∙B on leakage fault Soket type Specification Micom type Description Model No Type approval No Analog type DER-M10/M05 DER-A10/A05 07-9 07-8 Installation 07-3 07-7 DER-F03 DER-F11 DER-F12 DER-P03 DER-P11 DER-P12 승인미필 07-21 07-22 07-15 07-6 07-11 10c Flush mounted 1c Flush mounted Auxiliary voltage AC110/220V Frequency 50/60㎐ Nominal operating current(A) Current 1c Socket type 0.2-0.5-1.0 0.03-0.05-0.07-0.1 0.1-0.2-0.3-0.5 Operating 53%~75% of nominal operating current 1sec 이내 Non operating 52% nominal operating current 30sec 이내 Allowable supply voltage fluctuation 0.2-0.5-0.7-1.0 0.03-0.05-0.07-0.1 0.1-0.2-0.3-0.5 0.2-0.5-0.7-1.0 80%~120% of Rated Voltage Reset Manual/Auto(Muiti type) manual Warning circuit voltage Less than AC 600V Leakage indicator : Digital Leaking circuit indicator:Digital LED(Red color) LED indicator Buzzer alarm indicator : LED(Red color) Detector indicator:LED(Red color) Power indicator:LED(Green color) Power indicator:LED(Green color) ZCT penetration indicator:LED(Yellow color) ZCT penetrationindicator:LED(Yellow color) Continue/Auto-alarm:LED(Yellow color) Continue/Auto-alarm:LED(Yellow color) Buzzer alarm:LED(Yellow color) Buzzer alarm:LED(Yellow color) Detector alarm indicato:LED(Red color) Power consumption Non operating 4.5VA/4VA 9VA/7VA Operating 7VA/6.5VA 10VA/8VA ZCT(Input) 2.5VA 3VA 200㎃/100㎷ Ampient temperature -10℃+ 50℃ Sound level Buzzer(more than 75dB) Primary-case Insulation resistance Secondary-case more than 100㏁ (DC 500V megger) Primary-Secondary Primary-case:1500V Dielectric strength Secondary-case:500V AC 60㎐, 1miniute Primary-Secondary:1500V Impluse wave withstand voltage Vibration strength Mechanical shock resistance Contact capacity Between-terminal Power terminals-case On duty:Full wave width 1㎜, 1000rpm, 10min, Not on duty:Full wave width 4㎜, 1000rpm, 60min On duty:Natural drop 15times Not on duty:Accelebration of 50g Max force in any direction for 5 times AC 250V 3A, DC 30V 5A Rate of fuse Weight Casing 0.2A 2.0/1.8㎏ DEESYS TOTAL PRODUCTS GUIDE 0.1A 2.1㎏/2.0㎏ 0.7㎏ ABS Resin/Black N1.5(난연성 Non-flamable) ※ELR F03 사용시 SZR(니켈코어)을 사용해야 합니다. 122 Peak value : 6.0kV, 1.2/50㎲ 0.7㎏ 0.7㎏ 0.5㎏ 0.5㎏ 0.5㎏ Earth Leakage Fire Alarm & Relay [ELR]-1C, 5C, 10C Internal wiring connections External wiring of circuit breaking for leakage on load side External wiring of central control board leakage fault indicator BUZZER contact(No Voltage) ※ ZCT Common단자는 내부에서 연결이되어 있으므로 한단자만 사용해도 됩니다.(10C만 해당) External terminal arrangement DEESYS TOTAL PRODUCTS GUIDE 123 Earth Leakage Relay [ELR]-1C External wiring diagram Installation diagram Example for usage (leakage) Tripping For load break Tripping after setting For time delay Internal block diagram Cutting Size: 56x94mm 124 DEESYS TOTAL PRODUCTS GUIDE ※Dimension은 136page를 참조하십시오 Multi Function Ground Fault Relay [GFR]-5C, 10C 특징 DGF-M10 1) 집합형 지락검출계전기는 다수(10C 또는 5C)의 경계선로의 지락전류를 동시에 감지하며 각 선로의 현재 의 지락 전류량과 사고시 사고지락 전류량을 표시할 수있는 다기능 계전기입니다. 2) 8BIT MCU(A/D CONVERTER 내장)를 주회로에 첨단기능을 장착하여 신뢰성을 향상시켰습니다. 3) 종래의 단회로 지락검출계전기를 다수의 회로(5~10회로)를 1대에 수용한 집합형 계전기입니다. 4) 경지락 전류(0.1A)부터 중지락 전류(10A)까지 검출 가능합니다. 5) 배전선 보호 협조에 용이하도록 동작시간정정탭을 구성하였습니다. 6) 다양한 표시기능으로 CHECK 기능을 향상시켰습니다. 7) 자기감시기능(WATCHDOG FUNCTION)에 의해 오동작을 자체 방지합니다. 8) 각 선로의 최종 지락사고후 전류량을 메모리에 기억하므로 사고후 대책이 용이합니다. 9) 외부 케이스를 ABS 제품으로 대체하여 제품의 내구성을 향상시켰습니다. 10) E. M. C에 대한 시험을 하여 SURGE 및 고주파의 영향을 받지 않습니다. ※ 주) GFR 사용시 Aux, Ready Board 내장형과 외장형을 다음 페이지에서 구분 적용하여주시기 바랍니다. Features 1. Multi-ground fault relay(GFR) is multi-functional and is able to detect multiple ground faults of monitoring circuit and is displayed leakage in the circuit and fault current when earthing. 2. It is installed 8 bit MCU with A/D conventer and is configured to perform advanced functions for high relability. 3. It is a collective device that is intergrated many ground fault detector of conventional single unit. 4. It is capable to detect from minor grounding fault current(0.1A) to medium level fault current (10A) 5. It is configured to have operating time taps for adjustment of time setting is easy for protection coordination of distribution circuit 6. As wide display and indicators, it is able to enhance checking up and performance. 7. Watch dog function assures error - free operation. 8. The memory stores the last record of ground fault current of each circuit to facilitate following up in the event of accidents. 9. The ABS casing newly adopted offers improved durability and extended life of product. 10. All GFRs are tested EMC to ensures and high frequency & surge do not interfere design performance of GFR. Rating & Specification Items DGF-M10(For 10 Circuits DGF-M05(For 5 Circuits) Testign Institute Korea Electric Research Institute Usage for protection against minor and major ground Leakage faults Control Power Voltage AC 110/220V Operable in Common or AC 240V Frequency 50/60㎐ Operable in common Operating current setting 9steps, of 0.1, 0.3, 0.5, 1, 2, 3, 5, 10 and Lock T:70% to 100% of current setting Operating Time setting 9steps, of 0.05, 0.1, 0.3, 0.5, 1, 2, 3, 5, 10sec T:±10% for 0.05 T=0.1±25㎳ Ground Fault Detection Circuit 10Circuits 5Circuits Operating status Indicator LED (Red) and Digtal Display one for each Circuit Resetting Auto/Manual Ambient Temperature Vibration Resistance Impact Resistance Common frequency dielecric resistance Insulating Resistance Power Consumption -10℃~+50℃ Energized:Full vibration width 4㎜, 1000rpm, 10min Deenergized:Full vibration width 4㎜, 1000rpm, 10min Impact strength of 300㎨ applied to 3 axial directions of right & left. up & down, and behind & forward Opn Cir-Casing : AC 2000V Opn Cir-Opn Cir : AC 2000V Test Cir-Terminals : AC 1000V Opn cir Casing 10㏁ or more Opn cir-Opn Cir : 10㏁ or more Test Cir-Terminals : 10㏁ or more Weight by DC 500V megger 7VA Contact Capacity ZCT(input) 60㎐, 1min 5VA AC 125V 5A/DC 30V 5A 2.0㎏ 1.7㎏ ZCT Rating 200㎃/100㎷ (ZR, ZS, ZB type) DEESYS TOTAL PRODUCTS GUIDE 125 Multi Function Ground Fault Relay [GFR]-5C, 10C GFR 적용 구분 방법 Model DGF-M05T DGF-M10T DGF-M05 DGF-M10 DRB-005. 010 Combination None(Direct) Contact None 5C or 10C Contact Capacity DRB(Contact)AC 250V/10A AC 250V/10A Purpose Trip(MCCB) Alarm & Lamp, Trip(MCCB) Front plate 1. Line check button 2. Monitored circuit indicator(Digital) 3. Earth leakage level indicator 4. Hold check 5. Auto/Menu 6. Ground fault indicator for each circuit 7. Ground fault sensing current setting switch 8. Operating time setting switch 9. Self-test button for each circuit 10. Sensing current and operating time 11. Reset button 12. Power lamp 13. Sensing current setting check button 14. Operating time setting check button ※ 주의사항 ∙DGF-M10T, M05T 제품은 Breaker 차단용으로 Aux, Relay Board와 조합하여 사용하십시요. ∙DGF-M10, M05 제품은 경보 또는 Breaker 차단용을 위한 내장형으로 Aux, Relay Board 사용이 불필요합니다. 126 DEESYS TOTAL PRODUCTS GUIDE Multi Function Ground Fault Relay [GFR]-5C, 10C 개요 1. LINE CHECK(회로검사 스위치) 회로검사 S/W를 한번 누를때마다 한선로씩 회로 표시와 현재 선 로의 지락전류량이 표시됩니다. 2. LINE CHECK(감시회로 표시디지털) 각 감시선로를 숫자로 표시합니다. 3. LEAKAGE CURR(지락전류량 표시디지털) 각 선로의 현재 지락전류량 또는 사고전류량을 표시합니다. 9. 회로별 자체시험스위치 각 회로별 자체시험 스위치를 누르면 해당 선로의 지락사고등이 점등되고 실제 지락과 동일한 시험을 합니다.(설정된 시간동안 누 르면 동작됨) 10. 감도전류 및 동작시간정정표 각 선로의 지락감도전류 및 동작시간을 설정할 때 참고로 하는 표입니다. 4. HOLD CHECK(사고전류량 확인스위치) HOLD CHECK S/W 를 누르면 지락전류량 표시디지털에 각 선 로의 사고전류량이 표시됩니다. 11. 복귀스위치(RESET) 5. AUTO/MANUAL (자동/수동 복구 선택스위치) 자동/수동 선택스위치를 자동/수동 복구를 선택합니다. 12. 전원등(녹색 LED) 계전기에 전원전압(AC 110/220)이 정상적으로 공급될 때 점등됩 니다. 6. 회로별 지락사고표시등 지락사고 발생시, 회로별 자체시험 스위치를 누를 경우 해당회로 의 표시등이 점등됩니다. 7. 지락전류감도정정스위치 해당 선로의 특성에 맞게 0.1~10(A)중 선택하여 설정합니다. 계전기의 전기능을 초기상태로 환원시키는 스위치입니다. (사고메모리 Reset 기능) 13. 감도전류 설정확인 스위치(Position Check) 각 선로의 지락감도 설정을 디지털에 표시하여 확인할 수 있습니다. 14. 동작시간 설정확인 스위치(Position Check) 각 선로의 동작시간 설정을 디지털에 표시하여 확인할 수 있습니다. ※ 주의: LOCK 위치 설정시에는 동작하지 않습니다. (선로 보수시) 8. 동작시간 정정 스위치 해당 선로의 특성에 맞게 0.05~10(S)중 선택하여 설정합니다. Outline Information 1. Line Check Button When the switen is pressed, one by one time monitored circuit number is changed to next circuit number and ground fault current level of the circuit is displayed. 2. Monitored Circuit Indicator(Digital) It indicates monitored circuit number in numberals. 3. Earth Leakage Level Indicator The level of earth leakage or fault current is displayed. 4. Hold Check Switch(Stored memory of fault current level) Pressing hold check switch, earth leakage level indicator is displayed fault current of each circuit. 8. Operating Time Setting Switch The switch is used to set required interval of operating time from 0.05 to 10 seconds. 9. Self-Test Button If the button of a circuit is pressed, the status of circuit is simulated to real ground fault and ground fault indicator lamp turns on to alarm fault status. 10. Sensing Current and Operating Time Reference Table It is a table of current and time values that can be quoted for current and time setting as the reference. 11. Reset Button The button, if pressed, is intialized entire relay function. 5. Auto./Manual Switch If the switch is set to auto position, warning lamp(Red LED) turns on to warn the status of the switch setting. 12. Power Lamp(Green LED) It turns on when the power of AC110/220V(or AC 240V)is regularly supplied. 6. Ground Fault Indicator Lamp The lamp of leaking circuit turns on when self-test button of the same leaking circuit is pressed. 13. Sensing Current Setting Check Button The button is used to display ground fault sensing current setting for checking purpose. 7. Ground Fault Sensing Current Setting Switch Select suitable step of sensing current between 0.1 and 10A rating as being reqired by characteristics of a line. ※Note : The relay does not operate in case of lock position 14. Operating Time Setting Check Button The button is used to display operating time setting of circuit for checking purpose. DEESYS TOTAL PRODUCTS GUIDE 127 Multi Function Ground Fault Relay [GFR]-5C, 10C 동작특성 1. 집합형 누전 검출계전기는 여러 회로를 집합하여 동시에 감시하 며 지락전류량 표시와 사고전류량 표시기능이 함께 내장된 계전 기입니다. 2. MCU의 선로감시 명령에 의해 모든 경계선로를 동시에 감시합니 다. 3. 경계선로에 지락전류가 발생하면 영상변류기에서 전압이 출력되 어 계전기의 지락전류검출회로에 입력됩니다. 4. 입력전압은 증폭처리된후 중앙처리장치에 입력됩니다. 6. 표시확인 : 두개이상의 선로에 지락사고가 발생하였을 경우, 회로 별 지락사고 표시등은 전부 점등하지만 지락선로표시 디지털과 지락전류량 표시 디지털에는 가장 먼저 지락사고가 발생한 선로 의 값만 표시합니다. 다른 선로의 값을 확인하고자 할 때에는 회로검사 스위치를 눌러 각 회로의 지락전류량을 점검할 수 있습니다. 만약 자동복구 상 태에서 이미 사고전류량이 소멸된 경우에는 HOLD CHECK 스위 치를 눌러 메모리된 사고전류량을 확인할 수 있습니다. 7. 복귀(RESET) : 선로의 사고를 보수한후 자동/수동 스위치가 수동 으로 설정되어 있을 경우에는 사고 표시가 지속되므로 복귀스위 치를 눌러 계전기의 기능을 환원시켜야 합니다. 5. 중앙처리장치는 증폭된 입력전압을 A/D로 변환하고 감도전류설 정값과 비교하여 설정값 이상이 될 때 다음과 같이 동작합니다. ① 동작시간정정치가 경과한후 해당회로의 지락 사고표시등이 점 등됩니다. ② 해당회로의 REPLAY가 동작합니다. ③ 지락전류량 표시디지털에 지락전류량이 숫자로 표시됩니다. ※ 주의 : 자동/수동 스위치를 자동으로 설정하였을 경우 적색 LED가 점등되고 지락전류가 소멸될 경우 자동적으로 발생한 모든 동작표시가 없어집니다. 동작특성 1. Multi-ground fault relay monitors a number of circuits collectively and carries built-in functional arrangement for ground leakage level indication and fault current level indication. 2. It performs monitoring of all circuits consequently by the command of MCU. 3. In case a ground fault current developed, it induces a voltage in ZCT which is fed to ground fault current detection circuit as an input. 4. After Input signal(voltage) is amplified, and then it is supplied to CPU for processing. 5. CPU converts input by A/D converter for comparison to set value of sensing current. And, if it is found more exceeding the setting value, it is performed as followings. 1) Turns on ground fault indicator lamp upon the elapse of setting interval of operating time. 2) Activates GFR or the circuit. 3) Indicates level of ground fault current on ground fault current indicator in numeral value. ※Note : If Auto/Manual switch is set to Auto position the warning lamp(Red LED) turns on, and the fault is repaired, all operating indication of the circuit will disappear automatically. 128 DEESYS TOTAL PRODUCTS GUIDE 6. Identification of indications : When leakages occur in plural number of circuits on sometime, ground fault indicator lamps for applicable circuits will light up at once. But ground fault circuit number indicator and ground fault current level indicator will display the value of first circuit detected. The values of other fault circuits can be checked by pressing circuit test button of respective circuit. If it is the auto reset mode, fault current has been cleared. Such fault current can be read out from the memory by pressing hold check button. 7. Reset If Auto/Manual switch is set to manual position after the ground fault is repaired, press reset button to initialize the performance or else fault indication will be kept on. Multi Function Ground Fault Relay [GFR]-5C, 10C 설치전 점검사항 (계전기를 설치하기전 다음 사항을 점검하여 계전기의 기능을 확인 하시기 바랍니다.) 5. 지락감도설정 확인스위치를 눌러 각 회로의 감도전류설정을 확인 하십시요. 1. 계전기의 P0, P1 단자에 전원전압(AC 110V 또는 220V)를 연결하 십시오. (주의: 계전기의 전원전압은 공장출하 설정치가 AC 220V입니다. AC 110V를 사용하실 경우 뒷면의 슬라이드 스위치를 AC110V로 전환 조정하여 사용하십시요.) 6. 회로별 자체시험스위치를 눌러 계전기의 내부회로를 점검합니다. 스위치를 누르면 해당 회로의 RELAY와 지락사고등(RED LED) 이 동작되며 지락전류표시 디지털에 20.5 를 표시하여 각 회로 의 이상유무를 확인합니다. (디지털 표시는 가상의 지락상태를 표 시하며, ZCT의 연결이 안된 상태에서의 숫자임) 2. 전원을 연결하면 전원등(GREEN LED)이 점등되어 전원 투입상 태임을 알립니다. 7. 자동/수동 스위치를 수동으로 설정하고 6. 항의 시험을 다시 행하 십시요. 3. 회로검사 스위치를 눌러 디지털표시를 점검합니다. 스위치를 누를때마다 회로표시가 1회로씩 순차적으로 변환되고 지락전류량은 888 을 표시합니다. 스위치를 누르지 않고 약 25초가 경과하면 자동으로 표시가 소멸 됩니다. 8. 이상의 시험이 끝나면 복귀스위치를 눌러 계전기를 초기상태로 환원시킵니다. 4. 동작시간설정 확인스위치를 눌러 각회로의 동작시간설정을 확인 하십시오. Checking Items Before Installation Check up following points befor installation in order to ensure satisfactory performance of GFR. 1. Connect AC 220V power lines to terminals Po and P1 of GFR. ※Note : Operating power is set to AC 220V at factory when delivered. If AC 110V is used, slide the power voltage selector switch to AC 110V position. 2. When the power os connected, power lamp(Green LED) turns on to indicate power suppy. 6. Check up internal circuits by pressing self- test button of each circuit. If the button is pressed of a circuit, relay of the circuit and ground fault indicator lamp(RED LED) and circuit indicator relay activate to show status of circuits.(The value of digital display represent assumed state of grounding fault). 7. Carry out the test of item 6 after auto/manual switch is set mannual position. 8. Return to the initial status by pressing the reset switch after finishing the above test. 3. Check up digital displays by pressing circuit test switch. The circuit number on display changes by advancing one circuit at each of pressing the button and ground fault current level indicator will remain displaying 888 all the while of testing. After an elapse of about 25 seconds or so without pressing test button further, the indication will disappear automatically. 4. Check up operating time settings of each circuit by pressing operating time check switch. 5. Check up fault sensing current setting by pressing ground fault sensing setting switch. DEESYS TOTAL PRODUCTS GUIDE 129 Multi Function Ground Fault Relay [GFR]-5C, 10C 설치시 점검사항 1. 설치하고자 하는 장소에 계전기의 치수에 맞게 판넬을 제작 취부 (매입) 설치합니다. 이어서 경계선로에 ZCT를 설치합니다. 2. 계전기 뒷면 단자 결선(외부결선도 참조) ① 부하용량에 맞게 ZCT 를 설치합니다. (ZCT 사양 및 용량 결정시 당사에서 생산하는 ELD용 ZCT를 사용하십시요.) ① 변류기측 2개의 단자 중(단자의 극성 구별은 없음) 1개는 계전 기 각회로 단자 ①,②,③,④,⑤,⑥,⑦,⑧,⑨,⑩에 결선하고 1개의 단자는 계전기 ⓩ공통단자에 연결합니다. ② 대전류모선 혹은 강한 자장으로부터 10Cm 이상의 위치에 설 치하여 주십시요. ② 계전기의 ⓐ~ⓘ 단자는 외부 릴레이 접점(a접점), COM 단자 는 외부 릴레이 공통 접점(c접점)으로 차단기구제어, 외부 경 보용 부져 및 중앙감시반 누전사고표시장치에 이용됩니다. ③ 단상/3상 구별없이 부하선로에 설치합니다. ④ 회로별 자체시험스위치를 눌러 계전기와 ZCT와의 단선유무를 검사합니다. ③ Ta, Tc 단자는 외보용 INDICATOR(부져, LAMP) 사용 접점 입니다. ④ 단자(E)는 접지단자로 배전반 그라운드로 연결합니다. 정격전압 5% 이내에서 ZCT가 계전기에 정상적으로 연결되어 있 을 시에는 지락전류량 표시디지털에 18미만의 숫자를 DIGTAL로 표시하고 단선시에는 18이상 숫자를 표시하였을 경우 수신기는 정상입니다. ⑤ 계전기의 전원은 다른 회로전원과 병렬로 연결하지 마시고 분 기이전의 별도 전원을 사용하십시요. Checking Items for Installation 1. Fabricate relay mounting panel of a suitable size and fix it on which GFR be installed. Then install ZCT on the circuits being monitored. ① Install ZCT of adequatable for the load (For selection of ZCT specification and current rating. use ZCT manufactured by us for ELD.) ② Ensuring GFR is in stalled at 10cm or more distance where there are large current bus and strong magnet field. ③ Install GFR on load circuit of single phase and three phase power without exception. ④ check confinuity between GFR and ZCT by pressing self-test button of each circuit line. The receiver is in nomal status if ground fault current level indicator shows a value in numerals Below of 18 if the connection of GFR and ZCT is correctly made, and a value of 18 if they are disconnected. 2. Connections to terminals on the back of GFR.(Refer to external wiring diagram) ① One of two ZCT terminals(no ploarities) Shal be connected to relay terminal of each circuit ①, ②, ③, ④, ⑤, ⑥, ⑦, ⑧, ⑨, and ⑩ and the other terminal to common terminal ⓩ of GFR. 130 DEESYS TOTAL PRODUCTS GUIDE ② With GFR, terminals ⓐ through ⓙ are‘a’contacts for external relays, and terminal COM is ‘contact’ for external relays. The terminals could be used for control of circuit breakers, external alarm buzzer, and leakage fault in dication on central control board. ③ Terminals Ta and Tc are provided to use the contacts for external indicators(buzzer, lamp). ④ Terminal (E) is for grounding which is connedted to the ground terminal of distribution board. (Refer to external wiring diagram for connections). ⑤ The control power of relay should be connected an independent sonrce which is not distributed from main source. Multi Function Ground Fault Relay [GFR]-5C, 10C Internal block diagram External contacts wiring diagram(Alarm & CB Trip contacts) External terminal arrangement Contact output type(Alarm & CB Contacts) Signal output type(CB Trip Contacts) ※ GFR-M10, 10T의 경우 단자 Z가 내부에서 연결이되어 있으므로 한단자만 사용해도 됩니다. DEESYS TOTAL PRODUCTS GUIDE 131 Aux Relay Board [Isolation]-5C, 10C Aux relay board is a power relay which controls output power according to the input signals of industrial uses, and consists of set type relays controlling MCCB or MC coils. Features �Ensure to use Aux Relays (DRB-010. 005) when DGF-M10, M05 are used to drive MCCB and trip rather than the using them as central control board lamp indication. �It is insulated completely between and among input, output, and power lines. �Single board is capable to control 5or 10 circuits �Formerly exposed aux relays are now internally located in order to prevent mal-functioning caused by moisture hazardous to insulation. GFR output Rated Specification MODEL DRB-010(10C), DRB-005(5C) Rated Voltage AC 110/220V Rated Frequency 50/60㎐ Relay Contact Rating AC 250V, 10A Inetrnal block diagram External wiring diagram Terminal arrangement External dimension 132 DEESYS TOTAL PRODUCTS GUIDE Ground Fault Relay-1C Flush mounted type Soket type Specification Model No Part DGF-P11(Socket type) DGF-P12(Socket type) DGF-F11(Flush mounted) DGF-F12(Flush mounted) Auxiliary power AC 110/220V common(DC110/220V Option) Frequency 50/60㎐ common Operating current setting Operating time setting 0.1-0.1-0.5-1-3-5-7-10-Lock 10-15-20-25-30-35-40-50-Lock INST-0.1-0.3-0.5-0.7-1-2-3-Lock INST-0.1-0.3-0.5-0.7-1-2-3-Lock Operation Indicator LED lamp (red color) Reset Auto / Manual Extent of supply voltage 85~115% of rated voltage Ambient temperature -10℃~+50℃ Power consumption 3VA Insulation resistane DC 500V, less than 100㏁ Dielectric strength primary-case ; AC 2,000V, Secondary-case : AC500V / 1minute Contact capacity AC 125V 5A / DC 30V 5A Weight 0.6㎏ Case ABS Resin/Black N1.5 ZCT(Input) ZCT Rating 200㎃/100mV(ZR, ZS, ZB type 사용) 특징 Features 이 정지형 접지검출계전기(GFR)는 ZCT(영상변류기)와 조합하여 접지 전류를 검출하며, 그 고장회로의 차단기를 차단하거나 경보를 울리게 할 수 있도록 출력접점을 내장하고 있습니다. 이 사양서에 표시된 동 작전류란 ZCT의 1차에 흐르는 전류를 의미합니다. 즉 이 ZCT 1차에 흐르는 전류를 기준으로 정정해야 하는데 이와 같이 정정된 전류가 ZCT 1차에 흐르고, 설정된 시간이 지나면 계전기의 출력(트립용 또는 경보용) 접점이 붙게 됩니다. 센서 ZCT의 2차는 GFR과 직접 연결되므로 발주시 한 조로 주문하는 것이 바람직 합니다. 모델“F-xx는 배전반 표면 부착용(플래쉬 마운팅 타입)이며, P-xx는 판넬 내장형으로 수분리형입니다. 자세한 내용은 이 매뉴얼의 관련 부분을 참조하시기 바랍니다. The static GFR with a sensor(Toroidal CT) is for ground fault current detection and has an output contact for a fault circuit trip. The relay is combined with a sensor which is calibrated as a set. The operating current in the specification means 1ry current of the CT. While the 1ry current is reached at set value. the output of the relay is closed. Since the 2ry output of the sensor is connected to the input of the relay. it is recommended that the relay with a sensing CT has to be ordered as a set. Model.“-F□□”is for semiflush mounting type and“-P□□”is for pin type with a base socket. Refer to the drawings in the instruction for more information. DEESYS TOTAL PRODUCTS GUIDE 133 Ground Fault Relay-1C 적용 Application 이 접지계전기(GFR)는 비접지 회로망에서 회로에 흐르는 영상전류(Io) 및 접지시 모선측에 발생하는 대지간 불평형 캐패시터 성분에 의한 전 류(Ic)가 ZCT를 통하여 흐르는 량을 감지하여 검출하는 방식입니다. 평상시 평형을 이루고 있던 3상간의 대지간 평형 정전용량이 일선 지 락으로 인하여 깨지면서 대지간 캐패시터 성분에 의한 불평형 전류가 발생 되는데 이 전류가 ZCT를 통하여 흐르게 됩니다. 접지전류(Io + Ic)정정 및 동작시간 정정은 명판위에 있는 로타리 스위치로 설정 할 수 있습니다. 이 로타리 스위치의 <LOCK> 위치에 맞추어 놓으면 이 기능은 작동하지 않습니다. 기능중 Manual(수동) 및 Auto.(자동) 선택 스위치가 있으며, Manual로 선택하면 접지 현상이 제거되어도 계전기 의 접점은 운전원이 RESET 스위치를 누를 때까지 지속적으로 붙어 있으며, AUTO로 선택하면 계전기에 접지가 제거되면 자동으로 출력 접점이 복귀됩니다. The GFR may be applied where fault circuits should be cut off detecting current, lo and unbalanced current. Ic in the non-grounding network. Capacitive components existing in the bus side from ZCT is balanced between earth and three phase conductors at the normal condition. The balanced capacitive components of three phases are broken as soon as for one of three phases being grounded. And then the capacitive current becomes to flow thru the ZCT. The fault current(lo + lc) can be set by rotary switches on the front plate of the relay. Time delay function is selected by the time switch as well. By turning to <LOCK> of the rotary switches for operating current and/or operating time, the function(s) can be disabled. Reset function for output contact can be selected either on Manual or on Auto. 정정, 시험 및 운전 Setting, Testing, and Operation 1. 전류정정 탭 0.1-0. 3-0. 5-1-3-5-7-10(A)-LOCK(총 9단계) 1. Current Set : There is a 9 step switch on the front plate for current set. One of 8 step(0.1, 0.3, 0.5, 1, 3. 5. 7. 10(A)) and lock, can be selected. 2. 동작시간 탭 Inst.(순시)-0. 1-0. 3-0. 5-0. 7-1-2-3-LOCK(총 9단계) 3. Power LED 보조전원이 공급되어 있으면 Power LED(초록)이 켜져 있습니다. 2. Time Set : There is a 9 step switch on the front plate for time set. a Instant set. 7 steps of delay time and a Lock set. 3. Power LED(Green) is lighted while aux. power is ON. 4. Trip LED 출력 접점이 출력 되면 Trip LED(적)이 켜집니다. 5. Manual/Auto 이 선택 스위치로 출력 접점을 유지하거나 자동 복귀할 수 있게 합 니다. Manual로 선택한 경우. 접지로 인하여 출력 접점이 붙었을 경우 RESET 스위치를 누르지 않는한 지속적으로 붙어있게 됩니다. Auto로 선택한 경우 접지 상태가 제거되면 즉시 출력 접점도 자동 복귀됩니다. 6. RESET 스위치는 동작 표시 LED 및 출력 접점을 복귀하는데 사용 합니다.(Manual 선택시) 7. TEST 버튼은 출력 접점 이상 유무를 확인하고자 할 때나 수동 시 험용으로 사용됩니다. 주의: 정상 운전시 이 TEST 버튼을 누르면 접점 S.W가 Manual에 있을 때에는 접점이 계속 유지되므로 반드시 Reset S.W 눌 러 주십시오. 134 DEESYS TOTAL PRODUCTS GUIDE 4. Trip LED(Red) is Lighted when any fault occurs and the output contact(terminal Ta and Tc) is closed at a same time. 5. Manual/Auto switch can be selected either Manual or Auto for reset. “Maunal” means for manual reset of output contact by pressing reset button and “Auto” means for automatic reset of output contact as soon as the fault current cleared. 6. Reset button is used for resetting TRIP LED and an output contact when Manual/ Auto switch has been turned to Manual. 7. Test button is used for self-circuit test. If the button is pressed manually, the output contact(a) is closed and TRIP LED is lighted simultaneously. Note : Do not press the <Test> button during in service. Main CB may be opened Ground Fault Relay-1C 개체시험 방법(시험회로도 참조) Test Procedure (Refer to the figure) 1. 아래의 그림 회로에서와 같이 ZCT의 2차(k-l)를 GFR 단자(7 -8)에 연결한다. 1. 2ry of sensor(k & l) and GFR(Terminal 7 & 8) are connected with wire. 2. 단자 1-3 에 보조 전원 AC110/220V를 연결한다. 2. Terminal 1 & 3 for AC 220V or terminal 1 & 2 for AC 110 aux. power is connected to a source. 3. 단상 전원의 1선만을 ZCT를 통과하게 하고 전원에 연결한다. 4. 계전기에서 전류 탭은 10A에 동작 시간 탭은 0.1초에 설정한다. 5. 보조전원을 켜고, POWER LED가 켜졌는지를 확인한다. 3. One line with an A-meter from current source is installed through the sensor CT. 4. GFR is set at 10A tap with current dial and 0.1 sec. tap with time dial on the front plate. 6. 전류 발생 장치를 이용하여 ZCT 1차에 12A를 맞춘다. 7. 전류 발생 장치에서 전류 스위치를 순간적으로 ON한다. 이 때 전류 가 12A가 흘렀는지 확인하고 타임 카운터가 0.1초 10%범위내에서 정지되었는지. 그리고 TRIP LED가 들어왔는지 확인한다. 8. RESET 스위치를 누르면 트립표시용 LED가 복귀한다. 만약 AUTO 로 선택했을 경우는 출력접점은 전류 OFF와 동시에 자동 복귀되고 트립표시 LED도 자동 복귀됩니다. 9. 다른 정정치에서도 위와 동일한 방법으로 시험 할 수 있다. 5. Aux. power switch is "ON". Then the power LED on the front plate may be lighted. 6. Current through the sensor CT is set 12A (120% of set value) using current source. 7. Switch current source instantaneously and watch through-current on A-meter whether 120% of set value is flowed. Then, confirm time on the time counter if it is counted 0.1±10%sec. (±10% of time set value) and if the trip LED is lighted. 8. Press RESET button for reset. If Reset selection is turned to Auto., the output contact will reset automatically, but the trip LED shall be reset manually like doing at Manual. 9. Other ranges can be tested same as the above procedure. Internal block diagram External wiring diagram DEESYS TOTAL PRODUCTS GUIDE 135 Ground Fault Relay-1C Dimension MODEL : DGF-P11, DGF-P12, DER-P03, P11, P12 �Flush mounted type 1,2 : AC110V/120V 1,3 : AC220V/240V 4,5,6 : a,b,c - Contact MODEL : DGF-F11, F12, DER-F11, F12 Cutting Size : 56x94mm 7,8 : Z,C,T Input External dimension(GFR-M10/M05, ELR M10/M05, ELR-A10/A05) Cutting Size: 165 X 122mm 136 DEESYS TOTAL PRODUCTS GUIDE 국가형식검정품(한국소방검정공사) Low Voltage Zero-Phase Sequence Current Transformer ■Zero Phase Sequence Current Transformer [ZR, ZS, ZB, SZR-Series] ■Zero Phase Sequence Current Transformer [ZB-Series] ■Cable & Busbar Through Type [ZR, ZS, ZB, SZR-Series] ■Busbar Mold Type Zero Phase Sequence Current Transformer [3∅ 3W] ■Busbar Mold Type Zero Phase Sequence Current Transformer [3∅ 4W] ■How to Installation and Inspection ZCT 영상변류기(ZR, ZB, ZS) Zero-Phase Sequence Current Transforme [ZR, ZS, ZB, SZR-Series] ● 고투자율 Core를 사용 직선성 및 안정도를 높였습니다. ● 고감도용(SZR TYPE)은 Nickel Core를 사용하여 30mA의 작은 전류도 정확히 검출합니다. ● 다양한 Model을 구비하여 선택의 폭을 넓혔습니다. ● 대량 생산을 통해 보다 저렴한 가격으로 공급하고 있습니다. ● As it is used high magnetivity core, it has high linear characteristics and safety characteristics. ● As SZR type ZCT (Sensitivity type) is used Nickel core, it is possible to detect small current(30mA) correctly ● As various model, it is very easy to select the ZCT Ordering Procedure ZR - O3O 025-25∅ ZR-for ELD, GFR 030-30∅ ZR 050-50∅ HZR-for High Voltage Ralay HZR 065-65∅ SZR 080-80∅ 100-100∅ SZR-for High sensitivity & Static type Directional Ground Relay 120-120∅ 150-150∅ 200-200∅ 150-150㎜ ZS-square type ZS SZS 200-200㎜ 250-250㎜ ZB3-Busbar mold type(3 wire) 400-400A 600-600A ZB4-Busbar mold type(4 wire) 800-800A ※ 주 의 : 상기 Series ZCT는 2차 출력이 전압형으로 ELD 및 Static Type Realy에 적용할 수 있는 특성을 갖고 있으며 유도형 계전기에는 적용이 불가합니다. ※ Note : Because the above ZCT is voltage type on 2ry output and has characteristics applicable with ELD and static type relay, it is impossible to apply for induction type relay. 138 DEESYS TOTAL PRODUCTS GUIDE ZB3 1000-1000A 1200-1200A 1400-1400A 1600-1600A ZB4 Zero-Phase Sequence Current Transforme [ZR, ZS, ZB, SZR-Series] ● For earth leakage detector ● For indoor ● Cable & Busbar through type ● Casing ASB (Non-flamable) ● Color : ZR, ZS SZR, HZR, SZS type-Black(N1.5) 소방검정공사 형식승인품(ZR Type) (Type approval by inspection agency for fire) Specifications Model Cable Through Type Busbar through type ZR-025 SZR-025 ZR-030 SZR-030 ZR-050 SZR-050 ZR-065 SZR-065 ZR-080 SZR-080 ZR-100 SZR-100 ZR-120 SZR-120 ZR-150 SZR-150 ZR-200 SZR-200 ZS-150 ZS-200 ZS-250 Rated Current(A) Inside dia. (㎜) 80 Through wire(EV)㎟ Zero phase current ratio Pri./Sec Dimensioon (page) Weight (㎏) 109 0.4 109 0.5 38 109 0.7 150 100 109 0.9 400 250 200 109 1.5 100 500 325 250 109 2.2 1000 120 - 850 725 109 3.4 1400 150 - 1000 850 109 4.0 2000 200 - 109 7.5 400 400 600 30×150 30×200 30×250 109 109 109 2.8 3.5 3.8 1∅2W 1∅3W,3∅W 3∅4W 25 38 8 5.5 100 30 60 14 8 250 50 150 80 400 65 325 600 80 800 ※6T×25 - ZR,SZR type 200㎃/100㎷ (75~125㎷ at 2㏀) SZR Type 30㎃/50㎷ ※6T×25 ※6T×25 ※ Note : 1.“※”Mark is busbar size 2. SZR Type ZCT는 고감도(30mA)용으로서 NIckel Core를 사용하였습니다. 3. ZR, Type ZCT는 Test terminal이 없습니다. 필요한 경우 별도 주문하셔야 합니다. ∙Use to Temperature : -10℃~+60℃ ∙Withstand voltage : AC 2000V/Min.(between secondary coil and base) ∙Insulation resistance : More Then 1000㏁ DC 500V(bettween coil and base) SZR ZCT Digital DGR 200mA/100mV ELR-Po3. DER-Po3적용 30mA/50mV 영상변류기(Z.C.T)동작원리 (1)정상상태(Normal Condition) (2) 지락누전상태(Ground Fault Condition) DEESYS TOTAL PRODUCTS GUIDE 139 Zero-Phase Sequence Current Transformer [ZB-Series] ■ ■ ■ ■ ■ For Earth Leakage Detector For Indoor Busbar Mold Type Bake-lite case Color : Munsell No N1.5(Black) Specifications Model ZB3-400 ZB4-400 ZB3-600 ZB4-600 ZB3-800 ZB4-800 ZB3-1000 ZB4-1000 ZB3-1200 ZB4-1200 ZB3-1400 Rated Current(A) Busbar Size(㎜) 400 6T×50 600 6T×50 800 6T×75 1000 8T×75 1200 Zero phase current ratio Pri./Sec Dimension(page) Weight(㎏) 110 4.3 111 7.4 110 4.3 111 7.4 110 6.6 111 8.8 200㎃/100㎷ 110 8.0 (75~125㎷ at 2㏀) 111 11.0 8T×100 110 12.4 1400 10T×100 110 15.0 1600 10T×100 110 15.0 ZB4-1400 ZB3-1600 ZB4-1600 ※ ZB3 : 3�, 320 / ZB4 : 3�, 420 ∙Use to Temperature = -10℃~ + 60℃ ∙Withstand Voltage : AC 2000V/MIN Between primary conductor and secondary coil Between Pri. Sec. coil and base ∙Insulation Resistance : More than 1000M at 500V DC Between primary conductor and secondary coil Between Pri. Sec. coil and base ∙Busbar 표면은 도금이 되어 있지 않습니다. 석도금이나 은도금이 되야 할 경우는 주문시 지정해주시기 바랍니다. ∙ZB Series ZCT는 Test terminal이 없습니다. 필요할 경우 별도 주문하셔야 합니다. 140 DEESYS TOTAL PRODUCTS GUIDE Cable & Busbar Through Type [ZR, SZR, ZS-Series] Round type UNIT(m/m) Model-No A B C D E F G H ZR/SZR-025 25 25 87 95 110 9 30 20 ZR/SZR/HZR-030 30 25 108 100 114 7 32 32 ZR/SZR/HZR-050 50 25 131 100 122 7 32 36 ZR/SZR/HZR-065 65 26 143 114 133 7 39 37 ZR/SZR/HZR-080 80 34 174 160 180 7 40 40 ZR/SZR/HZR-100 100 38 203 160 180 7 40 40 UNIT(m/m) Model-No A B C D E F G H Hole(�) ZR/HZR 120 45 225 180 210 20 55 35 10 ZR/HZR 150 45 260 180 210 20 55 35 10 ZR/HZR 200 53 310 260 286 10 70 35 10 Square type UNIT(m/m) Model-No A B C D E F G H I ZS-150 50 150 50 250 50 30 50 130 51 ZS-200 50 200 50 300 50 30 50 130 51 ZS-250 50 255 50 350 50 30 50 130 51 DEESYS TOTAL PRODUCTS GUIDE 141 Busbar Mold Type Zero-Phase Sequence Current Transformer [3 3W] ● 400-600A(80�) Model-No A B C D E F G H I J Hole(�) ZB3-400 50 6 300 100 100 200 160 40 188 195 6 ZB3-600 60 6 300 100 100 200 160 40 188 195 6 Model-No A B C D E F G H I J Hole(�) ZB3-800 75 6 320 100 100 200 160 40 215 230 6 ZB3-1000 75 8 320 100 100 200 160 40 215 230 6 Model-No A B C D E F G H I J Hole(�) ZB3-1200 100 8 330 140 140 280 180 35 210 260 10 Model-No A B C D E F G H I J Hole(�) ZB3-1400 100 10 350 140 140 280 180 35 210 260 10 ZB3-1600 100 10 350 140 140 280 180 35 210 260 10 800-1000A(100�) 1200A(150�) 1400-1600A(150�) 142 DEESYS TOTAL PRODUCTS GUIDE Busbar Mold Type Zero-Phase Sequence Current Transformer [3 4W] 400-600A(120�) Model-No A B C D E F G H I J K Hole(�) ZB4-400 50 180 6 35 300 100 100 100 300 210 225 10 ZB4-600 50 180 6 35 300 100 100 100 300 210 225 10 Model-No A B C D E F G H I J K Hole(�) ZB4-800 75 180 6 35 320 100 100 100 300 210 260 10 ZB4-1000 75 180 8 35 320 100 100 100 300 210 260 10 800-1000A(150�) Note : In case of leakage indication appears in plural at a time. check if wiring connetion is wrongly done as drawn example. In case that circuit NO 2 is leakaged, it is normal to indicate NO 2 circuit signal only. But because common wire is not connected to No1~No5 circuit, so No1~No5 circuits are indicated leakage singal simunltaneously. (How to check)check the resistance between common wire and No 1 circuit~No 10 circuit. It is 30~70Ω on normal condition and is infinity in disconnection condition. DEESYS TOTAL PRODUCTS GUIDE 143 How to Installation and Inspection Note : Incorrect installation of ZCT may result in malfunctioning of relay. Please refer to follwing wiring diagrams WRONG CONNECTION RIGHT CONNECTION 1) Load on neutral line will cause malfunctioning 1) All of two lines of 1∅ 2W. three lines of 1∅ 3W. three lines of 3∅ 3W. and four lines of 3∅ 4W should go through ZCT. 2) Because of load current on neutral line, the current between AB cause erro operation. The relay may not activate relay operation in cases of leakage. 2) Cut off line B and provide class 2 grounding as required for ZCT. 3) As load current is divided between A and B grounding, it will cause missing operation in case of leakage. 3) Earth the wires before ZCT to (the side of power source). 4) When neutral line and distribution board line are jointly connected to ZCT. malfunction will be introduced as the example of 3) above. 4) Provide class 3 grounding seperately for neutral line and distribution board each 5) Leakage indication lacks accuracy. 5) Install ZCT correctly 6) Occurrence of leakage will not activate relay operation. 6) Grounding of frame should be installed after(in the down stream) the ZCT connection point. Even if grounding is intentionally made to frame to frame, the leakage flows directly into to casing grounding without going through ZCT. Note : The frames are transformer casing, cubicle enclosure, and structural steel frames. 144 DEESYS TOTAL PRODUCTS GUIDE Motor Protective Relay ■Motor Protective Relay ■3E, 4E Motor Protective Relay MPR(4E,3E) 모터보호계전기(4E, 3E) Motor Protective Relay 정지형 Motor-Relay의 개요 Static type Motor-Relay ● MOTOR RELAY라 함은 많은 종류가 있으나 산업설비의 전력용으 로서 가장 많이 사용되고 있는 것은 3상유도전동기이며 이것을 보 호하는 것을 모터 RELAY라 합니다. 모터의 보호는 중요하며 이상 을 빨리 감지하여 부하의 피해를 최소한으로 막고 모터의 수명 및 파손을 방지하여야 합니다. ● 모터의 소형화, 경량화 됨에 따라 보호하는 모터 RELAY에도 고성 능, 고신뢰도가 요구되어 종래의 단순한 썸머 RELAY형에서 정지 형으로 변형되어 가고 있습니다. �MOTOR relays ranging wide in types refer to those relays purposed to protect three phase induction motors that are prime source of motive power at most industrial facilities. Motor protection by means of earlier detection of fault status to minimize overload damage is important for long motor life and avoiding damages. �Ensuring with the trends of motors becoming compact and light-weighted, motor protection relays (MPR) being required of high performance and reliability are featuring static state a change from the conventional simple thermal relay structure. Motor relay의 기능(Function) Element Feature No. Remarks 1. Overload 51 ∙Prevent motor burning. 2. Open phase 46 ∙Minnmize damages to work loads. 3. Reverse phase 4. Ground fault 47 50G (Careful selection is necessary for correct application.) ∙Offer protection against leakage damages caused by motor insulation faults. 과부하요소(Over load) ● 모터가 과부하가 되어 과전류가 장시간 흐르면 모터가 타버립니다. 그러므로 모터의 손상을 막기 위해서는 즉시 차단하여 모터를 보호 해야 합니다. ● 유도 전동기는 일반적으로 가동시 500~600% 정도의 과전류가 수초에서 수십초간 전류가 흐릅니다. ● 이때 모터 RELAY 동작하면 모터의 오동작 상태가 되므로 가동시 간의 설정을 정확히 할 필요가 있으므로 동작시간 요소는 반드시 필요합니다. ● 전류값에 대해서는 JEM1357에서 규정하는 전류정정치의 105~125%의 범위내로 정하고 있으며 특별히 지정이 없는 모터에 는 이 규격으로 적용합니다. ● 동작시간에 대해서는 동일시각인 JEM1357에서 정하는 전류정정치 의 600% 과전류에서 40초 이하 200%의 과전류에서 4분이하로 정하고 있습니다. 결상검출요서(Open phase) ● 모터의 전원선이 단선되면 TERMINAL 접속부등의 풀림, 개폐기등 의 접촉불량 모터자체 COIL의 단선등에 따라 3상 운전되는 모터가 단상으로 운전되는 상태를 말합니다. ● 모터가 정지되고 있는 상태에서는 단상 운전이 이루어지지 않으며 결상상태에서 기동하면 기동전류가 지속적으로 흐르기 때문에 과부 하(OVER LOAD)로 인한 검출을 하여 모터의 소손을 방지 할 수 있습니다. ● 모터가 정상회전되고 있는 상태에서 결상이 되어 단상 상태가 되고 부하가 작으면(경부하) 모터는 계속 운전될 수 있습니다. 146 DEESYS TOTAL PRODUCTS GUIDE Elements for overload �Over loaded operation of motor will flow of over current. Long time operation of a motor in over current status would result in motor burning and that current should be cut-off immediately for protection against the burning. �Induction motors normally require 5 to 6 times starting currents than rating current during a few seconds while starting. �Should the relay react to such starting over current, the motor will be in operation fault status. In order to avoid such a state. precise setting of operating time will be necessary. �Current rating is set within the range of 105% to 125% of the current setting prescribed in JEM 1357 for all motors unless otherwise specified. �Relays are timed to operated in 40 seconds or less at 600% over current of the set level as specified in JEM 1357 and 4 minute less at 200% over current likewise. Element for open phase �Open phase operation refers to a state of motor operation in which a three phase motor would run in single phase power because of loosened terminal connection faulty switch contact or disconnected motor coil �Three phase motor does not start in single phase power from halt status that continous attempt to start in an open phased state will occur over current. Detection of overload status is essential to save the motor from burning. �Should the motor is developed an open phase while the motor is in rotation the motor may rotate continuous if the load is resonably low. Motor Protective Relay Phase current Vector During one phase open Current detecting (CD) or Voltage detecting mathode(VD) (Fig1) ∙nomal ∙one phase open (External) (Fig3) ∙△ phase open (Internal) 그림2와 같이 변류기를 사용하지 아니하고 전압방식으로 결상을 검출 하는 방식도 있으나 결상검출의 접속점부터 MOTOR까지는 검출이 안 되며 전원측 결상이라 하여도 MOTOR의 부하가 경부하 상태의 운전 중이면 MOTOR에는 단자전압이 걸려 있기 때문에 결상이 검출이 되 지 않는 경우가 있기 때문에 전류검출방식의 결상을 검출하는 것이 가 장 바람직합니다. ● 과전류 요소 만으로는 결상시 모터의 소손을 방지하지 못하는 경우 가 있어 결상요소가 필요합니다. ● 경부하 시에는 결상이 되어도 과전류라고 할수 있는 전류가 흐르지 못하므로 결상검출이 되지 않습니다. 이상을 신속히 검출하기 위하 여는 결상요소가 필요합니다. ● 결상검출 방식은 전압 방식도 있으나 전류방식이 가장 유리합니다. 반(역)상 검출요소(Reverse phase) ● 3상유도전동기는 상순이 바뀌게 되면 모터의 회전방향이 반대로 됩 니다. 모터가 잠깐이라도 반대를 돌게되면 모터의 부하에 치명적인 영향을 끼칠수 있습니다. ● 그러므로 모터의 상순이 역으로 되면 즉시 검출하여 차단시키는 반 상요소가 필요합니다. ● 이 경우에는 모터의 3상 전압을 검출하여 모터의 역회전을 방지합 니다. ● 그림3의 경우 마그네트 전에 반상을 접속했을 경우 반상 상태가 되 면 모터를 기동시키기 전에 검출하게 됩니다. ● 그러기 때문에 이 경우는 절대로 모터의 기동전에 검출하므로 안전 하게 됩니다. ● 특히 전원이 이동될 경우의 모터는 접속변경이 많으므로 이 경우에 는 필히 부착하는 것이 바람직합니다. Phase reverse detecting mathode(Fig2) As shown in Fig. 2, open phase is detectable by voltage method without requiring use of a current transformer. The method does not, however, offer ability to detect open phase status between detector contact point to motor. In case of line side open phase, terminal voltage exists if the motor is running with light load that open phase may not be detectable. For this above reason, the current detections method is desirable. �Since over current measure alone may not always be able to prevent motor burning, consideration of open phase measure will be necessary. �In case of running with light load, the current in phase fault may not be large enough to be detected as over current that status of open phase may not be detected. For this reason, application of open phase measures for prompt detection of phase fault will be necessary. �For this reason, use of current detection method will be most advantageous although voltage detection method is available too. Element for open phase �Changes in phase sequence of three phase motor would reverse the direction of rotation. Revers rotation even for a short time would be detrimental to the lead critically. �Reverse phase performance for immediate detection and instantaneous circuit breaking is essential whenever the phase is reversed. �Reverse roation is preventable by three phase voltage detection. �As shown is Flg 3. reversed phase can be detected before starting the motor if the detector is connected before the magnetic switch. �The connection as such assures complete safety as it detects reversal factor absolutely before starting. �When power cource is changed. Installation of the detector is highly desirable because wiring of motor may be misconnected very often. DEESYS TOTAL PRODUCTS GUIDE 147 Motor Protective Relay Motor Relay의 특징 ● 모터는 역율을 개선시키기 위해 모터에 병렬로 진상용 콘덴서를 설 치하게 됩니다. 모터의 경부하시에 흐르는 전류는 대게 무효분이며 고조파가 함유됩니다. 그래서 진상용 콘덴서를 접속하여 불필요한 고조파를 없애줍니다. 이것이 큰경우에는 50/60Hz의 정현파로 설 계되어 있는 결상 및 반상 회로등이 오동작 할 우려가 있습니다. 대 부분의 경우에는 오동작의 경우는 거의 없으나 진상용 콘덴서를 MOTOR 전단에 설치하여 정확한 과전류동작치를 감지하여 선로의 이상 발생을 보호할 필요가 있습니다. ● MOTOR 전류의 불평율의 경우 보통은 수% 정도이나 장시간 오래 사용한 V결선 변압기를 통하여 모터전원이 공급되고 있는 경우는 약 10~20% 이상의 불평형율이 나타나고 있습니다. Motor Relay의 특성 MCT(Motor relay 용 Current converter) ● MCT(Current Converter)는 MOTOR RELAY를 동작시키기 위 하여 AC전류를 DC 전류로 바꾸어 변환시켜 줍니다. ● 특히 내장된 탭을 변경 사용할 수 있어 폭넓은 전류를 사용할 수 있습니다. ● CONVERTER에 20A TAP에 선정하였을 때 MCT에 2회 권선 하면 10A의 전류에서는 20A의 흐르는 전류로 검출하기 때문에 10A에서 동작 시킬수 있다. 같은 방법으로 4회 감으면 5A에서 도 동작 시킬수 있습니다. Characteristics of Motor Relay �For the purpose of improving power factor, lead factor capacitor is installed in parallel to the motor. Usually the motor current at light load is Var power containing harmonic waves. The capacitor is installed to absorb unnecessary harmonic wave. But if the capacity is too large, the open phase and reverse phase detection circuits designed with 50/60㎐ sine wave may operate faulty. Although such a case would rarely occur, performance of circuit needs to be protected from malfunctioning by determination of over current reacting point, as having the capacitor installed before the motor relay. �In general, motor current shows unbalance by several percent. However, in case of power supply through long used transformer of V connection, it may swing up to 10-20 percent or even more. Features of Motor Relay MCT(current converter for moter relay) �MCT converts AC current into DC voltage to operate motor relays. �By changing built-in taps. current level can be selected in steps. �If 20A tap of MCT is selected and wounded 2 times. 10A input current will be detected as 20A that the relay can be operated at 10A current and if would 4 times, the relay can be operated even at 5A MCT출력전압특성표(MCT output voltage characteristics) 과부하요소(OVER LOAD) ● MCT에서 반환된 DC전압을 통하여 MOTOR RELAY의 입력에 서 받아 과부하 검출이 시작됩니다. 이때 전류 정정탭에 정해져 있는 설정치이상 흐르게 되면 동작이 시작됩니다. ● 과부하 상태가 되면 시간정정에 맞는 반한시성으로 동작됩니다. 이때의 과전류 동작시간은 전류정정치의 600%의 과전류가 흐 를경우 1~40초 범위로 변화시킬 수 있습니다. ● 동작이 되면 출력 RELAY는 HOLDING 됩니다. Element for over load �Over current is detected by DC voltage obtained from input of the motor relay after conversion. Should the current exceed the level set by current regulating taps, the relay becomes activation. �The relay operates in inverse time limit to set time when overloaded, the over current active time length can be adjusted within a range of 1 to 40 seconds when the current is greater 600 percent than the set value. �If the relay is operated, the output relay becomes to holding status. 148 DEESYS TOTAL PRODUCTS GUIDE MCT TAP Input current Output voltage 20A 8A 8V 40A 16A 8V 80A 32A 8V Motor Protective Relay 결상요소 결상시의 동작치 및 동작시간 특성은 그림6, 그림도7과 같이 MCT의 3상 출력 파형을 검출하여 결상의 상태를 판별하여 구동시킵니다. ● MOTOR RELAY는 결상 검출이라기보다 불평형율을 검출하도록 설계되어 있으며 불평형율 약 35% 또는 65%에 동작되도록 SETTING 되어 있습니다. ● 결상요소의 동작시간은 불평형 35% 이상시 약 1.6초에 동작합니 다.(고속도 setting 시) Fig6 Open phase Open phase relay is activated according to current and time characteristics when open phase status is detected by three phase output wave form of MCT as shown in Fig. 6 and 7. �Motor relays are designed more as current unbalance detector than open phase detector. They are set to operate approxirmately at 35 percent or 65 percent level of current unbalance. �Active time in open phase is approximately 1.6 seconds in an unbalance of 35% or more (for High-speed action setting.) Fig7 반상요소 모터의 역회전을 방지키 위한 반상보호로 구성되어 전원전압(3상)을 이용하여 구동시킵니다. ● 전원전압의 V.W상을 이용하여 자체 MOTOR RELAY에 POWER 를 공급합니다. ● 과부하, 결상은 MCT(CONVERTER)를 이용하여 3E RELAY가 동작되나, 반상 검출상태는 3상의 전압을 이용하여 동작됩니다. 외부결선 방식 ● 결선시 과부하 및 결상 방법은 MCT에서 검출된 DC �, � 전압을 가지고 3E RELAY를 동작시키므로 반상 검출이 필요치 않을 경우 에는 U상의 결선이 필요하지 않습니다. ● M.G COIL과 계전기 V.W 전원은 동일 전원 상에 연결하는 것이 좋습니다. ● 진상용 콘덴서는 CONVERTER보다 전단에 설치하십시오. 후단에 넣게 될 경우 3E RELAY의 전류 SETTING시에 콘덴서의 전류를 합성하여 정정해야 합니다. ● CURRENT CONVERTERDML 결선시에 �와 �의 극성을 정확히 RELAY와 결선하여 주십시오. ● 3E RELAY 결선시 MOTORDML 전원전압(3 ) 과 3E RELAY의 전원이 U.V.W에 3� 전압이 결선되므로 사양선택시 주의하십시오. ● CONVERTER 1차측에 변류기(CT) 2차측을 이용할 경우에는 MCT-31을 사용해야 합니다. Reverse phase The relay is featured for reverse phase protection circuit and driven by line voltage(3�) �Driving power is supplied to motor relay through using of U-V phase of line voltage. �In case wiring connection to W phase terminal is removed, overload and open phase elements are activated but reverse phase element does not. �In case of over load and open phase, 3E relay is activated by the power from MCT and in case of reverse phase, it is operated by 3 phase power. How to connect wiring �Since 3E relay is operated by power of DC voltage detected at MCT for overload and open phase detection, connection of W phase is not necessary unless reverse phase detection is intended. �It is perferrable for MG coil and U-V ends of relay to share same power source. �Phase advance capacitor should be tapped on before converter (at upstream). If tapped on after (close to load end) the load, set current of 3E relay should include capacitor current. �For connection of relay to current converter, polarity of DC current should not be reversed. �Since three phase line voltage is connected to motor and U-V-W phase of same line voltage is connected to 3E relay, selection of relay should be carefully made to desired specifications. �When an use of CT output for converter input is intended, MCT-31 should be used. DEESYS TOTAL PRODUCTS GUIDE 149 Motor Protective Relay 삼상불평형율 계산방법 예) Example of 3 phase unbalance calculation 3상불평형회로 역상분 불평형률= Unbalance = factor X 100% 3상불평형회로 정상분 1a+a2ib+aic 역상분 정상분 = 100 1a+a2ib+a2ic 100 =1. 60 100 =0.6, 70 100 =0.7 ) Table for unbalance ratio 150 Ratio(%) 1.0 1.0 1.0 0 1.0 0.9 0.8 12 1.0 0.8 0.7 24 1.0 0.7 0.6 36 1.0 0.6 0.65 39 1.0 0.5 0.65 51 1.0 0.4 0.75 55 1.0 0.3 0.8 66 1.0 0.2 0.85 77 1.0 0.1 0.9 95 DEESYS TOTAL PRODUCTS GUIDE Above formula above shall be quoted to determine unbalance ratio. For example, assume R phase=100A. S phase=60A, T phase=70A R:S:T=1:0.6:0.7 ( 으므로 아래 표를 이용하여 부하의 불평형률에 대한(%)를 구할 수 있습니다. 이때 불평형률은 36%를 알 수 있습니다. Unbalance X 100(%) Reverse component 1a+a2ib+aic = normal component 1a+a2ib+a2ic 3상의 불평형률은 위의 식을 참고 바랍니다. 예를 들어 부하의 전류상태가 R상=100A, S=60A, T=70A R:S:T=1:0.6:0.7 ( 3phase unbalance circuit reverse component 3phase unbalance circuit normal component 100 100 =1. 60 100 =0.6, 70 100 =0.7 ) that unbalance ratio in percentage can be read from the table at right. In the case of this example. unbalance ratio is 36% as read from the table. 3E, 4E Motor Protective Relay MPR 3E MPR 4E MCT Feature Feature 1. 3상 유도전동기가 확실하게 보호되며 과부하 결상(단상운전)및 반상 (역상)을 4E일 경우 지락까지 신속히 검출하여 모터의 소손을 방지 합니다. 2. 광범위한 전류정정과 시간정정을 1대로서 가능합니다. 3. 입력회로에“Surge” 방지회로가 있어서 오동작의 염려가 없습니다. 4. 반도체 H-IC회로로서 기기오차는 물론 반영구적으로 사용할 수 있 습니다. 5. D4E형은 ZCT(영상변류기)를 이용하여 지락으로 인한 사고를 방지 할 수 있습니다. 1. Protection for 3 phase motor with certain in any cases : over load, single phase operating, reverse, even earth fault. 2. Wide range of current setting and time setting in one unit. 3. Input circuit is equipped with "surge" protection circuit for no error 4. Built in semiconductor H-IC circuit : And strong against shock and vibration. 5. D4E type protects motor from earth fault with ZCT Products Rated Voltage Model No 3E Rated Current Function D3E-F41 AC 110V Flush mounted D3E-F42 AC 220V Over load D3E-F43 AC 380V Open phase Flush mounted D3E-P41 AC 110V Revers phase Socket type D3E-P42 AC 220V D4E-011 AC 110V Over load Open phase D4E-022 Flush mounted Socket type 4E Reverse phase AC 220V Ground Fault MCT Installation MCT-31 Less than 600V 1-80A A/V(converter) MCT-32 Less than 600V 61-160A A/V(converter) Flush mounted Flush mounted DEESYS TOTAL PRODUCTS GUIDE 151 3E, 4E Motor Protective Relay Specification Deseription 3E Motor rating 4E Cirult voltage Less than AC 600V(3∅) Primary voltgae Rated current AC 1-80A to 64-160A, Primary current Rated voltage AC 110V, AC 220V, Ac 380V(3∅) Extent voltage 85%~110% of Rated voltage Frequency 50/60㎐ common Contact capacity AC 125V 10A, AC 250V 6A(cos∅=1.0), DC 30V 5A, AC 250V 3A(cos∅=0.4) Control power Power consumption VA Operating value Operating time curve AC 110V, 220V, 380V 3.5VA AC 110V, 220V 7VA 10VA Operation 115% of current set value(105~125%) Inverse Inverse, Definite(Ground) When over load 600% of current set Element of over load Operating time Inverse:Same as 3E Operating time tap×1(1~10sec) Ground Fault : More than Operating time tap×4(4~40sec) Reset Current set value More than 100% of current set value Operating value Less than 75% of current set value Unbalance factor H(high sensitivity set)35±10%, L(Low sensitivity)65±10% Element of open phase Operating time Less than 4 sec Value of Operation Less than 80% rated voltage Operating time Starting Lock Less than 1 sec Starting holdtime 5sec/10sec/15sec SL(start lock) Ambient temperature Insulation resistance ON(operating) OFF(Non operating) Operating value:±10%(-10℃~+50℃), operating time:±20% ∙primary-case ∙secondary-case ∙primary-case Dielectric strength ∙secondary-case More than 10㏁ AC 2000V 1 min ∙Mutually dry contact : AC 1000V 1min 1.2/50㎲ positive, negative polarity : 3 times Impulse wave withstand voltage Electric circuit to case : 5㎸ Aux power to terminal : 4.5㎸ 152 Over load P’ ry current circuit Multiple 20 of current set value Factor Control power circuit Multiple 1.15 of rated voltage(3 Hours) Vibration strength Viabration frequency 16:7㎐, amplitude 4㎜ Mechanical shock resistance 500㎨ (50g) DEESYS TOTAL PRODUCTS GUIDE 3E, 4E Motor Protective Relay Front plate Over load operating time characteristic Single phase operating characteristic Internal block diagram DEESYS TOTAL PRODUCTS GUIDE 153 3E, 4E Motor Protective Relay Current setting table Motor Relay Current setting Motor Power 220V 4P Model Current Converter(M.C.T) Current times ratio Cable Turns Times setting tap 1~2.5 0.25 8 20 2~5 0.5 4 20 4`~10 1 2 20 (rated current × sticker no) tap 1 2 KW 0.2 HP 1/4 A 1.6 3 0.4 1/2 2.5 4 0.75 1 3.8 5 1.5 2 6.6 6 2.2 3 9.1 8~20 2 1 20 MCT 7 3.7 5 14.6 8~20 2 1 20 -31 8 5.5 7.5 21.8 16~40 4 1 40 9 7.5 10 28.2 16~40 4 1 40 10 11 15 40.9 32~80 8 1 80 11 15 20 54.5 32~80 8 1 80 12 22 30 78.2 64~160 16 1 fixed 13 30 40 104.5 64~160 16 1 fixed 14 37 50 128.2 64~160 16 1 fixed 5 2~5 0.5 4 20 In case of over 37㎾ using other C.T 15 MCT -32 Operating time setting be set from starting to normal operating time(3phase lnduction motor) MCT -31 1. Above motor power : 4 pole 1800rpm case 2. In case high voltage 3 phase induction motor, use high voltage CT (2nd tated 5A, 10VA) Operation indication(OC, RVS, OPEN) Over current : OC Reverse : RVS Open phase = OPEN Part Settting ON OFF ×1 ×4 H L ON,OFF ON OFF Over Current Open Phase Reverse Characteristic Over current factor using Over current factor No using Operating time 1~10sec Operating time 4~40sec Operating unbalance rate 35% Operating unbalance rate 65% ON,OFF Reverse factor using Reverse factor No using Operating current In case setting current 16A 16 X 1,15=18.4 Overload current become 18.4A, operating start. MCT setting 20 20 20 20 40 80 Fixed 154 Current Setting ratio ×0.25 ×0.5 ×1 ×2 ×4 ×8 ×16 4 5 6 1 2 4 8 16 32 64 1.25 2.5 5 10 20 40 80 1.5 3 6 12 24 48 96 DEESYS TOTAL PRODUCTS GUIDE 7 8 1.75 2 3.5 4 7 8 14 16 28 32 56 64 112 128 9 10 Operating time setting 2.25 4.5 9 18 36 72 144 2.5 5 10 20 40 80 160 According to starting current time of load, set between 1~40secs. Time Tap Multiple ×1 (sec) ×4 1 1 4 2 2 8 3 3 12 4 4 16 5 5 20 6 6 24 7 7 28 8 8 32 9 10 9 10 36 40 3E, 4E Motor Protective Relay Manual(3E, 4E RELAY) ※ 취급상 주의 상항(Remark) ■ Reted current and penetrating turns(table 1) Ampere(A) Penetrating turns 1-2.5 8 2-5 4 4.-10 2 more than 8 1 취급상 주의 상황 1. 정격전류와 도체관통회수의 관계는 동작 특성상 대단히 중요함으로 상기 표1을 참고하시어 필히 지켜주시기 바랍니다. 2. 정격전류가 1-80A는 MCT-31을 사용하고 64-160A는 MCT-32를 사용하여 주십시요. 3. MCT에 도체관통회수는 정격전류에 따라서 표1에 표시된 회수로 3 선과 다같이 같은 방향으로 설치하여 주십시요. 4. 고압 및 대용량의 전동기의 경우는 시판되고 있는 변류기의 2차측 을 MCT에 관통시켜주십시요. 5. 3E,4E,REALY의 경우 3�전압을 정확한 상순으로 3�모두 결선하 십시요.(U.V.W) Remark 1. Refer to above table 1 and decide penetration turn according to the using ampere carafully 2. In case of rated current 1-80A, MCT-31 can be used, and in case of 64~160A, MCT-32 can be used. 3. MCT penetrating wiring turns refer to table 1 and bind the 3 wire(3�) to same direction. 4. In case high voltage and big capacity motor, normal CT'S secondary side should be penetrated through the MCT. 5. In case of 3E, 4E relay, connect all the 3 phase wire to normal phase process(U, V, W). MCT Dimension DEESYS TOTAL PRODUCTS GUIDE 155 3E, 4E Motor Protective Relay 사용방법 Application 1. MCT의 정정방법 (제품출하시 전류정정 20A에 정정되어 있음 )( MCT -31경우) 전동기의 정격전류에 따라 MCT에 표시된 도체관통회수와 정정탭을 설정합니다. 예)정격전류가 4-10A의 경우는 표1에 의해 관통회수 : 2회 표2에 의해 정정탭20 2. 전류정정 배율 스티커 MOTOR RELAY전류정정값은 4-10으로 스티커 정격전류와 맞게 붙여서 사용하십시요. (표2참조) 예)정격전류가 4-10A의 경우는 1이됩니다. 3. 전류정정방법 MOTOR RELAY의 전류정정은 스티커 숫자와 전류정정값의 베율로 하여 정격전류값을 정확히 맞추어 주십시요. 이때 동작값은 정정값 의 115%가 됩니다. 예)정정값 5A 목성배율 스티커0.5일 때, 정정전류값 : (5A X 0.5)→2.5A 동작전류값 : (2.5A X 1.15)→2.9A±10% (table2) MCT Setting tap 20 40 80 2. Current setting ratio sticker Motor relay current setting value 4~10 can cooperate with rated current sticker's Example) In case rated current 4~10A, setting value become 1 3. How to set current Motor relay current setting should be decided by current times ratio setting and current setting value. At this time, operating value is 115%. Example) In case setting 5A ratio sticker setting current value:(5A×0.5)→2.5A Operating current value:(2.5A×1.15)→2.9A±10% (unit:A) Current Setting ratio X0.25 X0.5 X1 X2 X4 X8 X16 4 5 6 7 8 9 10 1 2 4 8 16 32 64 1.25 2.5 5 10 20 40 80 1.5 3 6 12 24 48 96 1.75 3.5 7 14 28 56 112 2 4 8 16 32 64 128 2.25 4.5 9 18 36 72 144 2.5 5 10 20 40 80 160 4. 시간정정방법 시간정정 배율은 스위치 위치에 따라(X1, X4) 서 선택하면 됩니다. 이때의 시간은 600%과전류시의 동작시간을 표시합니다. (단위:초) 예) 시간정정탭 5 목성배율 X 4 정정시간은 20초 (5 X 4) 따라서 동작시간은 20초임. ※ 주의 : (1) 수중모타는 5sec이하에 Setting 해 주십시요. (2) 일반 3상 유도전동기의 경우 기동시부터 정상운전까 지의 시간에 설정함. 5. 동작표시 복귀방법 동작표시기가 동작하면 적색 LED가 켜집니다. 이때 출력접점은 지 속(Holding)되기 때문에 점검후 복귀(RESET)보턴을 누르면 원래의 상태로 돌아갑니다. 6. 시험방법 MOTOR RELAY에 시험(TEST)보턴을 눌러 계전기의 동작상태를 확인할 수 있습니다. (단, 동작시까지 계속 눌러 주십시요.) 156 1. How to set MCT (Current setting is set 20A at factory)(MCT -31) Select the setting tap and conductor penetrating turn according to the motor rated current. Example) In case rated current 4-10A, penetrating turn setting tap will be 20 according to table 1. DEESYS TOTAL PRODUCTS GUIDE 4. How to set time Time setting ratio can be selected by switch position(×1, × 4) At this time, it mean 600% over current operating time (unit:sec) Example) Time setting tap : 5 Ratio : ×4 Setting time 20sec (5×4) Operating time is 20 seconds ※Note : In case of under water pump, please set less than 5 seconds. In case of normal 3 phase induction motor, set the time from starting to normal operating. 5. Operating indication & how to reset In case operating indicator, red LED is turned on. At this time, output contactor become holding condition. After checking, all situation can be returned by pressing reset button. 6. How to test Motor relay operating test can be done by pressing test button. 3E, 4E Motor Protective Relay 7. 접속후 기동전의 확인 및 시험방법 7. Before starting, how to confirm. MCT 관통회수와 방향 MCT penetrating No and direction MCT와 3E, 4E RELAY와의 극성 (+,-) 확인 MCT and 3E, 4E relay polarity(+,-) confrmation 제어전류 인가 Control power supply 3상 전원상순(U,V,W) 확인 Confirmation 3 hase order(U,V,W) 반상시험(3상) 전압의 상을 바꾼다. Revers test (change the phase) 정상 U,V,W 반상 V,U,W 순간 동작하면 정상 In case of instantaneous operating, it is normal 정상위치로 되돌린다. Return to normal position OCR시험(TEST)보턴을 누른다. 지락 TEST 보턴을 누른다 (정상시간 이상)(3E) (4E) Press OCR test button (over setting time)(3E) Press earth fault test butto(4E) 동작한다. Operate 정상 Normal 8. 지락전류정정 및 시험방법(4E relay) (1) 감도전류는 0.1, 0.2, 0.3, 0.5, 0.7, 1.0, 1.5, 2.0, Lock(A) 9Tap 입니다. (2) 시간은 0.1, 0.2, 0.3, 0.5, 0.7, 1.0, 2.0, 5.0 Lock(sec) 9Tap 입니다. (3) 전류와 시간동작 후 GR TEST 보턴을 누르면 Setting 시간과 동일하게 동작합니다. (4) OCR동작시 OC LED가 켜지고 GR동작시 GR LED가 켜집니다. (5) 동작후 RESET 보턴을 눌러 정상위치를 확인하지 않으면 모터 의 기동시 기동이 되지 않습니다. (6) ZCT는 모터의 용량에 맞게 주문하시면 됩니다. 8. How to set earth fault current and test (4E relay) (1) Sensible current is 0.1, 0.2, 0.3, 0.5, 0.7, 1.0, 1.5, 2.0, Lock(A) 9taps (2) Time is0.1, 0.2 0.3 0.5 0.7 1.0 1.5 2.0, 5.0 Lock(sec) 9taps (3) After current and time setting by the pressing GR test button, it operate according to setting time. (4) In case operating OCR, OC LED is on and in case operating GR, GR LED is on (5) Without confirmation of normal position by pressing reset button, motor can't start. (6) ZCT can be ordered with suitable capacity. 보수∙점검 Maintenance and inspection 1. 3E, 4E, RELAY 자체가 결상 상태가 아닌가 기동시간 이하에서 동작할 때. 2. MCT의 도체관통회수 및 방향 3선 모두 일정한가. 3. RELAY(3E, 4E)의 전원전압 및 MCT의 심한 불평 In case of operating at under starting 형이 되지 않은가 TEST보턴을 눌러서 RELAY가 동작하여 표시 되는데도 모터회 로가 차단하지 않을 때 RELAY 점점의 Ta, Tb, Tc를 풀어서 Relay 접점의 도통 관계를 확인한다. In case motor circuit tripping failure even if relay operating indication comes out by pressign test button 1. 3E,4E Relay is open phase itself 2. MCT penetration turn No and direction is correct or not all 3 wire 3. Power suppling voltage of relay and MCT are unbalance? After disconneting terminals of relay contact Ta, Tb, Tc, check whether the relay contacts are energized or not. DEESYS TOTAL PRODUCTS GUIDE 157 3E, 4E Motor Protective Relay External wiring diagram (3E Relay) �Manual operating (Low voltage) External wiring diagram (4E) Dimension (4E) Casing : 난연성(Non-flamable) color : Black(N1.5) 158 DEESYS TOTAL PRODUCTS GUIDE �High voltage motor External terminal 3E, 4E Motor Protective Relay Indoor zero sequence transformer specification (Ground protection) Rated current Inside diameter (A) (∅) ZR-030 100 30 ZR-050 250 50 Model no. EV penetration Cable ㎟ 3∅ 3W Weight 3∅ 4W (㎏) 14 8 0.5 80 38 0.7 ZR-065 400 65 150 100 0.9 ZR-080 600 80 250 200 1.5 ZR-100 800 100 325 250 2.2 UNIT(m/m) Model-No A B C D E F G H ZR/SZR-025 25 25 87 95 110 9 30 20 ZR/SZR/HZR-030 30 25 108 100 114 7 32 32 ZR/SZR/HZR-050 50 25 131 100 122 7 32 36 ZR/SZR/HZR-065 65 26 143 114 133 7 39 37 ZR/SZR/HZR-080 80 34 174 160 180 7 40 40 ZR/SZR/HZR-100 100 38 203 160 180 7 40 40 Dimension [D3E]-매입형(Flush mounted) Casing : 난연성(Non-flamable) color : Black(N1.5) [D3E] - 소켓형(Socket type) Casing : 난연성(Non-flamable) color : Black(N1.5) DEESYS TOTAL PRODUCTS GUIDE 159 Power Transducer ■Power Transducer ■Voltage Transducer ■Current Transducer ■Watt Transducer ■Var Transducer ■Watt/Watt Hour Transducer ■Var/Var Hour Transducer ■Power Factor/Phase Angle Transducer ■Frequncy Transducer ■Analog to Pulse Transducer ■Zero Sequence Voltage Transducer(V0) ■DC mV/DC V Transducer ■Isolator/Temperature Transducer Transducer 전력용 변환기(일반형) DEESYS TOTAL PRODUCTS GUIDE 161 Power Transducer Description �DEESYS transducers are designed to accept AC current and Voltage input and provide DC proportional current and voltage output with high accuracy. �DEESYS transducers are compact instruments that have outstanding overload and temperature performance. �DEESYS transducers provide high capability for long distance transmission of output, micro processing equipment and other converters. General specification Head Auxiliary power Input burden Input over capability Specification AC 110/220V(±10%), 50/60㎐(1.5VA) Less than current 0.5VA, Voltage 0.6VA Current rated : 1.2 In continuous 2 In 10sec 10 In 3sec Voltage rated : 1.2Vn continuous Response Output ripple Operating temperature range Less than 400ms, step change 0~95% Ripple less than 0.5%Ro peak-peak.(span) -10℃ to + 55℃ Operating humidity Calibrate adjustment Zero adjustment External magnetic field Dielectric strength Output load Surge/Impulse Case material 162 DEESYS TOTAL PRODUCTS GUIDE 0~99%, non-condensing ±1% minimum ±1% minimum Less than 0.01% 100AT/1M center Terminal to case : 4000V AC rms 1minute Input to output : 2000V AC rms 1 minute DC current mode : max 10V drop, DC voltage mode : max 5mA drive IEC255-4, 5㎸, 1.2X50㎲, IEC 255-22-1, 2.5kV(1MHz/400Hz) ABS resin, DIN rail type Voltage Transducer �High accuracy 0.1% or 0.2% �Excellent long term stability �High magnetic field immunity �Meets IEEE SWC test. �Outstanding overload and temperature performance. �Stability : Maximum 0.01%. ℃ Description DEESYS Voltage transducers have good linearity and low ripple output. The elements are totally isolated among input, output, power and others to case. This voltage transducer provide proportional DC current and voltage output which are not influenced by any load resistance, even under very low load condition, accurate output is available with quick response. Transducers are designed to respond to the voltage value of input but calibrated to root mean square (RMS) reading of pure sinusoid. Ordering procedure ∙CLASS : 0.1 or 0.2 ∙DEESYS VOLTAGE T/D ∙SOURCE 1. 1∅ 2. 1∅×3EA ∙INPUT 1. 0~150V 2. 0~300V 3. Option ∙OUTPUT 1. DC 4~20mA 2. DC 0~20mA 3. DC 2~10V 4. DC 1~5V 5. Option ∙HZ 1. 60HZ 2. 50HZ Standard product DVT- Model Output Source DVT-1111 DC 4~20mA 1∅ DVT-1121 DC 0~20mA 1∅ DVT-1211 DC 4~20mA 1∅ DVT-1221 DC 0~20mA 1∅ DVT-2111 DC 4~20mA 1∅X3EA DVT-2121 DC 0~20mA 1∅X3EA DVT-2211 DC 4~20mA 1∅X3EA DVT-2221 DC 0~20mA 1∅X3EA Order made is avaliable except for standard products. Output/Load resistance Output Load Compliance Ϊ 0~20mA �500 4~20mA �500 2~10V �2K 1~5V �1K DEESYS TOTAL PRODUCTS GUIDE 163 Voltage Transducer Installation and operation ■ Output Linearity Mounting and dimension ■ 3 Element ■ 1 Element Connection diagram ■ 3 Element 164 DEESYS TOTAL PRODUCTS GUIDE ■ 1 Element Current Transducer �High accuracy 0.1% or 0.2% �Excellent long term stability. �High magnetic field immunity. �Meets IEEE SWC test. �Outstanding overload and temperature performance. �Stability : Maximum 0.01%. ℃ Description DEESYS Current transducers have good linearity and low ripple output. The elements are totally isolated among input, output, power and others to case. This ampere transducer provide proportional DC current and voltage output which are not influence by any load resistance, even under very low load condition, accurate output is available with quick response. Transducers are designed to respond to the current value of input but calibrated to root mean square (RMS) reading of pure sinusoid. Ordering procedure ∙CLASS : 0.1 or 0.2 ∙DEESYS Ampere T/D ∙SOURCE 1.1∅ 2.1∅ × 3EA ∙INPUT 1.0~5A 2.0~1A 3.Option ∙OUTPUT 1.DC 4~20mA 2.DC 0~20mA 3.DC 2~10V 4.DC 1~5V 5.Option ∙HZ 1.60HZ 2.50HZ Standard product DAT- Model Output Source DAT-1111 DC 4~20mA 1∅ DAT-1121 DC 0~20mA 1∅ DAT-1211 DC 4~20mA 1∅ DAT-1221 DC 0~20mA 1∅ DAT-2111 DC 4~20mA 1∅X3EA DAT-2121 DC 0~20mA 1∅X3EA DAT-2211 DC 4~20mA 1∅X3EA DAT-2221 DC 0~20mA 1∅X3EA Order made is avaliable except for standard products. Output/Load resistance Output Load Compliance Ϊ 0~20mA �500 4~20mA �500 2~10V �2K 1~5V �1K DEESYS TOTAL PRODUCTS GUIDE 165 Current Transducer Installation and operation ■ Output Linearity Mounting and dimension ■ 3 Element ■ 1 Element Connection diagram ■ 3 Element 166 DEESYS TOTAL PRODUCTS GUIDE ■ 1 Element Watt Transducer �High accuracy 0.1% or 0.2% �Excellent long term stability. �Real power-able to measure distorted waveform �High magnetic field immunity. �Meets IEEE SWC test. �Outstanding overload and temperature performance. �Stability : Maximum 0.01%. ℃ Description DEESYS Watt transducer are designed to accept DC voltage or current and provide output(VI cos�) with high accuracy and quick response. Internal circuit are composed entirely of high quality components and power calibration equipment for measuring exact power energy. Ordering procedure ∙CLASS : 0.1 or 0.2 ∙DEESYS Watt T/D ∙SOURCE 1. 1∅2W, 2. 1∅3W 3. 3∅3W, 4. 3∅4W ∙INPUT(I) 1.0~5A 2.0~1A 3.Option ∙INPUT(V) 1.0~110V 2.0~220V or 190√3 3.Option or 380√3 ∙OUTPUT 1.DC 4~20mA 2.DC 0~20mA 3.DC 0~1mA 4.DC 1~5V 5.DC 4~12~20mA(±WATT) 6. Option Standard product DWT- Model Output Source DWT-11111 DC 4~20mA 1∅2W DWT-21111 DC 4~20mA 1∅3W DWT-31111 DC 4~20mA 3∅3W DWT-41111 DC 4~20mA 3∅4W DWT-11211 DC 4~20mA 1∅2W DWT-21211 DC 4~20mA 1∅3W DWT-31211 DC 4~20mA 3∅3W DWT-41211 DC 4~20mA 3∅4W Order made is avaliable except for standard products. Output/Load resistance Output Load Compliance Ϊ 0~20mA �500 4~20mA �500 0~1mA �10K 1~5V �1K ∙HZ 1.60HZ 2.50HZ DEESYS TOTAL PRODUCTS GUIDE 167 Watt Transducer Installation and operation ■ Output Linearity Mounting and dimension ■ 3 Element Connection diagram ■ DWT-3�3W ■ DWT-3�4W 168 DEESYS TOTAL PRODUCTS GUIDE Watt Transducer Theory of operation 1. Watt and Var of conversional equation Optional output P△, which in modulated according to the conversion method of watt and var transducer, are proportional to input current l△ and input voltage V△. P△=K∙V△∙l△[K:proportional constant] [1] For the satisfaction above [1] equation. Power(P) input voltage(V) input current(I) should be set up as an integral equation including time function P(t), K, V(t), I(t) Pw= 1 ∫ T T O V(t)I(t)dt Pw=VI cosφ[watt] Pr=VI sinφ[var] 2. Linearity and phase angle of input transformer Transducer's output linearity is depend on the transformer's primary and secondary turn ratio and phase stability. Especially under the low load transducer should be designed to maintain the linearity within 5%~10% range, which influence transducer output complience error. Winding Ratio a=I1/I2 I1=5%~100% I1k=akI2k ak=a(1±0.025%) I1k=a1kI2k �� I ± 10minutes I DEESYS TOTAL PRODUCTS GUIDE 169 Watt Transducer Theory of operation 2. Calibrating Watt/Var equation Cailbrating watt = Max scale value P.T ratio × CT ratio Ex1)3P 3W Network full scale of watt : 600㎾ P.T ratio : 3300/110V C.T ratio : 100/5A Cailbrating watts = Ex1)3P 4W Network full scale of watt : 2000㎾ 22900V 190V P.T ratio : 3 3 √ √ C.T ratio : 50/5A 600㎾ (3300/110) × 100/5 Cailbrating watts = = 1.0㎾ ( 2000kW 22900V 190V ×(50/5A) 3 √ √3 ) = 1.666kW Conversion Table Net work 1P2W 1P3W P.T.ratio(V) 110 110 220 380 /110 440 /110 3300 /110 6600 /110 22000 /110 22900 /110 Calibrating watts 3P3W 3P4W 154㎾ /110 208√3 380√3 /190√3 380 /√3 11400√3 /190√3 22900√3 /190√3 1.666㎾ 0.6㎾ 1.0㎾ 2.0㎾ 1.158㎾ 1.0㎾ 1.0㎾ 1.0㎾ 1.0㎾ 0.961㎾ 1.0㎾ 2.0㎾ 2.0㎾ 4.0㎾ 1.666㎾ 5/5 0.6 1 2 4 4 30 60 200 200 1400 2 4 4 100 200 10/5 1.2 2 4 8 8 60 120 400 400 2800 4 8 8 200 400 C.T.ratio 15/5 1.8 3 6 12 12 90 180 600 600 4200 6 12 12 300 600 20/5 2.4 4 8 16 16 120 240 800 800 5600 8 16 16 400 800 25/5 3.0 5 10 20 20 150 300 1000 1000 7000 10 20 20 500 1000 30/5 3.6 6 12 24 24 180 360 1200 1200 8400 12 24 24 600 1200 40/5 4.8 8 16 32 32 240 480 1600 1600 11.2㎿ 16 32 32 800 1600 50/5 6.0 10 20 40 40 300 600 2000 2000 14.0 20 40 40 1000 2000 60/5 7.2 12 24 48 48 360 720 2400 2400 16.8 24 48 48 1200 2400 75/5 9.0 15 30 60 60 450 900 3000 3000 21.0 30 60 60 1500 3000 80/5 9.6 16 32 64 64 480 960 3200 3200 2204 32 64 64 1600 3200 100/5 12.0 20 40 80 80 600 1200 4000 4000 28.0 40 80 80 2000 4000 120/5 14.4 24 48 96 96 720 1440 4800 4800 33.6 48 95 95 2400 4800 150/5 18.0 30 60 120 120 900 1800 6000 6000 42.0 60 120 120 3000 6000 200/5 24.0 40 80 160 160 1200 2400 8000 8000 56.0 80 160 160 4000 8000 250/5 30.0 50 100 200 200 1500 3000 10㎿ 10㎿ 70.0 100 200 200 5000 10㎿ 300/5 36.0 60 120 240 240 1800 3600 12 12 84.0 120 240 240 6000 12 400/5 48.0 80 160 320 320 2400 4800 16 16 112.0 160 320 320 8000 16 20 500/5 60.0 100 200 400 400 3000 6000 20 20 140 200 400 400 10㎿ 600/5 72.0 120 240 480 480 3600 7200 24 24 168 240 480 480 12 24 750/5 90.0 150 300 600 600 4500 9000 30 30 210 300 600 600 15 30 800/5 96.0 160 320 640 640 4800 9600 32 32 224 320 640 640 16 32 1000/5 120.0 200 400 800 800 6000 12㎿ 40 40 280 400 800 800 20 40 1200/5 144.0 240 480 960 960 7200 14.4 48 48 336 480 960 960 24 48 1500/5 180.0 300 600 1200 1200 9000 18.0 60 600 420 600 1200 1200 30 60 2000/5 240.0 400 800 1600 1600 12㎿ 24.0 80 80 560 800 1600 1600 40 80 2500/5 300.0 500 1000 2000 2000 15 30.0 100 100 700 1000 2000 2000 50 100 170 DEESYS TOTAL PRODUCTS GUIDE Var Transducer �High accuracy 0.2% or 0.3% �Excellent long term stability. �Real power-able to measure distorted waveform �High magnetic field immunity. �Meets IEEE SWC test. �Outstanding overload and temperature performance. Description DEESYS Var transducer are designed to accept DC voltage or current and provide output(VI sin∅) with high accuracy and quick response. Internal circuit are composed entirely of high quality components and power calibration equipment for measuring exact reactive power. Ordering procedure ∙CLASS : 0.2 or 0.3 Standard product DRT- Model Output Source DRT-11111 DC 4~20mA 1∅2W DRT-21111 DC 4~20mA 1∅3W DRT-31111 DC 4~20mA 3∅3W ∙DEESYS Var T/D DRT-41111 DC 4~20mA 3∅4W ∙SOURCE 1. 1∅2W, 2. 1∅3W 3. 3∅3W, 4. 3∅4W DRT-11211 DC 4~20mA 1∅2W DRT-21211 DC 4~20mA 1∅3W ∙INPUT(I) 1.0~5A 2.0~1A 3.Option ∙INPUT(V) 1.0~110V 2.0~220V or 190√3 3.Option or 380√3 ∙OUTPUT 1.DC 4~12~20mA 2.DC 0~10~20mA 3.DC 0~0.5~1mA 4.DC 1~3~5V 5.DC 4~20mA(cos� 1/4mA, LAG 0.5/mA) 6.Option DRT-31211 DC 4~20mA 3∅3W DRT-41211 DC 4~20mA 3∅4W Order made is avaliable except for standard products. Output/Load resistance Output Load Compliance Ϊ 0~20mA �500 4~20mA �500 0~1mA �10K 1~5V �1K ∙HZ 1.60HZ 2.50HZ DEESYS TOTAL PRODUCTS GUIDE 171 Var Transducer Installation and operation Output Linearity Mounting and dimension Connection diagram DRT-1∅2W DRT-3∅4W 172 DEESYS TOTAL PRODUCTS GUIDE DRT-1∅3W, 3∅3W Watt/Watt Hour Transducer �High accuracy Watt : 0.1% (Option)/ 0.2% + PF 0.15% W.H : 0.2% + PF 0.15% �Extremely excellent long term stability with. �Conversion method with R. C time constant devided of multiple equation. �Meets IEEE SWC test. �Outstanding overload and temperature performance. �Stability : Maximum 0.02%/℃ Description DEESYS watt/watt hour transducer are designed to measure the power and energy with various functions simultanously. Output is adopted time division multiplication method using the R.C. Watt hour output shall be provided various pulses according to the user's purpose and usage. Ordering procedure Standard product DWW- ∙CLASS : 0.1 or 0.2 ∙DEESYS WATT/WATT HOUR T/D ∙SOURCE 1. 1∅2W, 2. 1∅3W 3. 3∅3W, 4. 3∅4W ∙INPUT(I) 1. 0~5A 2. 0~1A Model Output Source DWW-111111 DC 4~20mA.1Pulse/Watthour 1∅2W DWW-211111 DC 4~20mA.1Pulse/Watthour 1∅3W DWW-311111 DC 4~20mA.1Pulse/Watthour 3∅3W DWW-411111 DC 4~20mA.1Pulse/Watthour 3∅4W Order made is avaliable except for standard products. 3. Option Output/Load resistance ∙INPUT(V) 1. 0~110V or 190√3 3. Option 2. 0~220V or 380√3 ∙OUTPUT(DC) 1. DC 4~20mA 2. DC 0~20mA 3. DC 0~1mA 4. DC 1~5V 5. Option ∙OUTPUT(Pulse) 1. 1Pulse/Watt hour 2. 1Pulse/10Watt hour 3. 10Pulse/Watt hour 4. Option Output Load Compliance Ϊ 0~20mA �500 4~20mA �500 0~1mA �10K 1~5V �1K ∙HZ 1. 60HZ 2. 50HZ DEESYS TOTAL PRODUCTS GUIDE 173 Watt/Watt Hour Transducer Installation and operation Output Linearity Mounting and dimension Connection diagram DWW-1∅2W DWW-3∅4W 174 DEESYS TOTAL PRODUCTS GUIDE DWW-1∅3W, 3∅3W Var/Var Hour Transducer �High accuracy Var : 0.2% (Option)/ 0.3% + PF 0.15% VarH : 0.3% + PF 0.15% �Extremely excellent long term stability with. �Conversion method with R. C time constant devided of multiple equation. �Meets IEEE SWC test. �Outstanding overload and temperature performance. �Stability : Maximum 0.02%/℃ Description DEESYS var/var hour transducer are designed to measure the power and energy with various functions simultanously. Output is adopted time division multiplication method using the R.C. Var hour output shall be provided various pulses according to the user's purpose and usage. Ordering procedure ∙CLASS : 0.2 or 0.3 Standard product DRR- ∙DEESYS VAR/VAR HOUR T/D ∙SOURCE 1. 1∅2W, 2. 1∅3W 3. 3∅3W, 4. 3∅4W ∙INPUT(I) 1. 0~5A 2. 0~1A ∙INPUT(V) 1. 0~110V or 190√3 3. Option 3. Option Output Source DRR-111111 DC 4~20mA.1Pulse/Var hour 1∅2W DRR-211111 DC 4~20mA.1Pulse/Var hour 1∅3W DRR-311111 DC 4~20mA.1Pulse/Var hour 3∅3W DRR-411111 DC 4~20mA.1Pulse/Var hour 3∅4W Output/Load resistance 2. 0~220V or 380√3 ∙OUTPUT(DC) 1. DC 4~20mA 2. DC 0~20mA 3. DC 0~1mA 4. DC 1~5V 5. Option ∙OUTPUT(Pulse) 1. 1Pulse/Var hour 2. 1Pulse/10Var hour 3. 10Pulse/Var hour 4. Option Model Output Load Compliance Ϊ 0~20mA �500 4~20mA �500 0~1mA �10K 1~5V �1K ∙HZ 1. 60HZ 2. 50HZ DEESYS TOTAL PRODUCTS GUIDE 175 Var/Var Hour Transducer Installation and operation Output Linearity Mounting and dimension Connection diagram DRR-1∅2W DRR-3∅4W 176 DEESYS TOTAL PRODUCTS GUIDE DRR-1∅3W, 3∅3W Power Factor/Phase Angle Transducer �High accuracy 0.5/3.0% �Excellent long term stability. �High magnetic field immunity. �Meets IEEE SWC test. �Outstanding overload and temperature performance. �Stability : Maximum 0.05%/℃ Description DEESYS power factor and phase angle transducer measure the load power factor and phase angle between one voltage and current. According to the load condition, model shall be devided two types balance and unbalance. Balanco type's external wiring is simple. Ordering Procedure ∙CLASS : 0.5 or 3.0 DPA DPF- ∙DEESYS POWER FACTOR T/D ∙SOURCE 1. 1∅2W, 2. 1∅3W 3. 3∅3W, 4. 3∅4W ∙INPUT(I) 1. 0~5A 2. 0~1A ∙INPUT(V) 1. 0~110V or 190√3 3. Option ∙OUTPUT(DC) 1. DC 4~12~20mA 2. DC 0~10~20mA 3. DC 0~0.5~1mA 4. DC 1~3~5V ∙HZ 1. 60HZ 2. 50HZ 3. Option 2. 0~220V or 380√3 Standard Product Model Output Source DPF-11111□ DC 4~20mA 1∅2W DPF-21111□ DC 4~20mA 1∅3W DPF-31111□ DC 4~20mA 3∅3W DPF-41111□ DC 4~20mA 3∅4W DPF-11211□ DC 4~20mA 1∅2W DPF-21211□ DC 4~20mA 1∅3W DPF-31211□ DC 4~20mA 3∅3W DPF-41211□ DC 4~20mA 3∅4W DPA-11111□ DC 4~20mA 1∅2W DPA-21111□ DC 4~20mA 1∅3W DPA-31111□ DC 4~20mA 3∅3W DPA-41111□ DC 4~20mA 3∅4W DPA-11211□ DC 4~20mA 1∅2W DPA-21211□ DC 4~20mA 1∅3W DPA-31211□ DC 4~20mA 3∅3W DPA-41211□ DC 4~20mA 3∅4W Order made is avaliable except for standard products. Output/Load resistance ∙LOAD 1 : Unbalance 2 : Balance Output Load Compliance Ϊ 0~20mA �500 4~20mA �500 0~1mA �10K 1~5V �1K DEESYS TOTAL PRODUCTS GUIDE 177 Power Factor/Phase Angle Transducer Installation and operation Output Linearity Mounting and dimension Connection diagram 178 DPF, DPA-1∅2W DPF, DPA-1∅3W(Blance) DPF, DPA-3∅3W(Blance) DPF, DPA-3∅4W(Blance) DPF-3∅3W(Unblance) DPF-3∅4W(Unblance) DEESYS TOTAL PRODUCTS GUIDE Frequency Transducer �High accuracy 0.3%(option)/0.5% �Excellent long term stability. �High magnetic field immunity. �Outstanding overload and temperature performance. �Stability : Maximum 0.04%/℃ Description DEESYS frequency transducers are demonstrated in a narrow frequency band and very suitable to detect the deviation from center frequency. Ordering procedure ∙CLASS : 0.3 or 0.5 ∙DEESYS Frequency T/D ∙SOURCE 1. 1∅2W ∙INPUT(V) 1. 110V 2. 220V 3. Option ∙OUTPUT 1. DC 4~20mA 2. DC 0~20mA 3. DC 2~10V 4. DC 1~5V 5. Option Standard product DFT- Model Output DFT-1111 DC 4~20mA DFT-1121 DC 4~20mA DFT-1211 DC 4~20mA DFT-1221 DC 4~20mA Source 1� Order made is avaliable except for standard products. Output/Load resistance Output Load Compliance Ϊ 0~20mA �500 4~20mA �500 0~1mA �10K 1~5V �1K ∙HZ 1. 60HZ(55HZ~65HZ) 2. 50HZ(45HZ~55HZ) DEESYS TOTAL PRODUCTS GUIDE 179 Frequency Transducer Installation and operation Output Linearity Mounting and dimension Connection diagram 180 DEESYS TOTAL PRODUCTS GUIDE Analog To Pulse Transducer �High accuracy 0.25% �Excellent long term stability. �Meets IEEE SWC test. Description DEESYS Analog to pulse transducers are designed to accept analog input and provide pulse output proportionally, suitable to measure the current consumption and total integration of various process. Ordering procedure ∙CLASS : 0.25 ∙DEESYS ANALOG TO PULSE T/D ∙INPUT(V) 1. DC 4~20mA 2. DC 0~20mA 3. DC 0~1mA 4. DC 0~5V 5. DC 0~10V 6. Option ∙OUTPUT 1. 100Pulse/Hour 2. 1000Pulse/Hour 3. 10000Pulse/Hour 4. Option Connection diagram Standard product DAP- Model Output DAP-12 1000Pulse/Hour DAP-22 1000Pulse/Hour DAP-32 1000Pulse/Hour DAP-42 1000Pulse/Hour DAP-52 1000Pulse/Hour Order made is avaliable except for standard products. Output/Load resistance Output Load Compliance Ϊ 0~20mA �500 4~20mA �500 0~1mA �10K 1~5V �1K Output linearity Mounting and dimension DEESYS TOTAL PRODUCTS GUIDE 181 Zero Sequence Voltage[V0] Transducer �High accuracy 0.1%(option/0.2% �Excellent long term stability. �Meets IEEE SWC test. �Stability : Maximum 0.01%/℃ Description DEESYS Zero sequence voltage(V0) transducers, when ground fault occur, detect the abnormal electric potential and convert to DC output for measuring, Ordering procedure ∙CLASS : 0.1 or 0.2 ∙DEESYS V0 T/D ∙INPUT(V0) 1. 0~150V(110V) 2. 0~260V(190V) 3. Option ∙OUTPUT 1. DC 4~20mA 2. DC 0~20mA 3. DC 0~1mA 4. DC 1~5V 5. Option ∙HZ 1. 60HZ 2. 50HZ Connection diagram 182 DEESYS TOTAL PRODUCTS GUIDE Standard product DVo- Model Output DVO-111 DC 4~20㎃ DVO-121 DC 0~20㎃ DVO-211 DC 4~20㎃ DVO-221 DC 0~20㎃ Order made is avaliable except for standard products. Output/Load resistance Output Load Compliance Ϊ 0~20mA �500 4~20mA �500 0~1mA �10K 1~5V �1K Output linearity Mounting and dimension DC mV/DC V Transducer �High accuracy 0.1%(option/0.2% �Excellent long term stability. �Meets IEEE SWC test. �Stability : Maximum 0.02%/℃ Description DEESYS DCmV transducers are designed to accept shunt secondary input for measuring the DC big current. DC volt transducers convert DC source to DC current or lower voltage for measuring. Ordering procedure ∙CLASS : 0.1 or 0.2 Standard product DDC- ∙DEESYS DC.V T/D ∙CHOOSE T/D 1. mV 2. V ∙INPUT(V0) 1. DC 0~50mV, 2. DC 0~100mV 3. DC 0~110V, 4. DC 0~120V 5. DC 0~150V, 6. DC 0~300V 7. ±50mV[-50mV(4mA) 0mV(12mA)+50mV(20mA)] 8. Option ∙OUTPUT 1. DC 4~20mA 2. DC 0~20mA 3. DC 2~10V 4. DC 1~5V 5. 0~10V 6. Option ∙HZ 1. 60HZ 2. 50HZ Connection diagram Model Output DDC-1111 DC 4~20㎃ DDC-1221 DC 0~20㎃ DDC-2311 DC 4~20㎃ Order made is avaliable except for standard products. Output/Load resistance Output Load Compliance Ϊ 0~20mA �500 4~20mA �500 2~10V �2K 1~5V �1K Output linearity Mounting and dimension DEESYS TOTAL PRODUCTS GUIDE 183 Isolator/Temperature Transducer �High accuracy 0.2%(only RTD/2.0% �Excellent long term stability. �Meets IEEE SWC test. �Stability : Maximum 0.02%/℃ Description DEESYS Isolator transducer is used for isolating DC circuit and among various senser insulation, converting DC input to other DC input. Temperature tranducers(RTD) which utilize the resistance variation are designed to accept temperature measure resistance meter output and provide proportional temperature output. Ordering procedure ∙CLASS : 0.1 or 0.2 Standard product DIS Model Output DIS-14 DC 1~5V ∙DEESYS ISOLATOR T/D DIS-51 DC 4~20㎃ ∙INPUT 1. DC 4~20mA, 2. DC 0~20mA 3. DC 0~1mA, 4. DC 0~1V 5. DC 1~5V, 6. DC 0~10V, 7. Option DIS-11 DC 4~20㎃ DRD-21 DC 4~20㎃ DRD-41 DC 4~20㎃ Order made is avaliable except for standard products. ∙OUTPUT 1. DC 4~20mA 2. DC 0~20mA 3. DC 0~1mA 4. DC 1~5V 5. DC 0~10V 6. Option Output/Load resistance Output ∙CLASS : 2.0 DRD ∙DEESYS TEMPERATURE T/D ∙TEMPERATURE RANGE 1. 0~50℃, 2. 0~100℃ 3. 0~150℃, 4. 0~200℃ 5. 0~300℃, 6. -50~+100℃, -100+100℃ 0~20mA �500 4~20mA �500 0~1mA �10K 1~5V �1K Output linearity ∙OUTPUT 1. DC 4~20mA 2. DC 0~20mA 3. DC 0~1mA 4. DC 1~5V Connection diagram 184 DEESYS TOTAL PRODUCTS GUIDE Load Compliance Ϊ Mounting and dimension 한국전기연구원 개발시험합격품 Induction Type Protective Relay ■Induction Protective Relay ■Induction Type Over Current Relay [OCR] 50/51 ■Induction Type Ground Over Current Relay [50N/51N] ■Induction Type Over, Under Voltage Relay [59] [27] [64] ■Induction Type Directional(Selective) Ground Relay [67] 유도형 계전기 OCR, OCGR, OVR, UVR, OVGR, SGR DEESYS TOTAL PRODUCTS GUIDE 185 Induction Protective Relay Ordering procedure �Over current relay D OC - A - CID4 DEESYS CO(OCR) for distribution C - Normal open contact CO(OCR) for receiving I - With instantaneous unit(Non symbol has no IIT coil) CG(OCGR) for distribution H - With holding coil CG(OCGR) for receiving D - Drawout case(Non symbol D is non drawout type) 5 - 0.5-2.5A(OCGR) 4 - 4 ‐12A 3 - 3 - 9A OCR (According to ordering for setting other current taps) 2 - 2 - 6A A - Inverse B - Very inverse LA-Long time(inverse) �Voltage relay D OV DEESYS CD1 OV(OVR) C - Normal open contact UV(UVR) O - Normal colsed contact VG(OVGR) D - Draw out case (Non symbol D is Non drawout type) 1 - 110V 2 - 220V 16 - 110V(60~90V) 26 - 220V(160~190V) 9 - 190V 15 - 15V 8 - 8V 5 - 5.5V �Directional(slective) ground relay D SG C D1 SG(SGR) DEESYS 186 DEESYS TOTAL PRODUCTS GUIDE (According to ordering for setting other voltage taps) Induction Protective Relay 보호협조 전력계통에 사용되는 계전기는 전계통의 계전기가 상호 보호협조가 되 어야 합니다. 특히 과전류 계전기의 보호 협조는 더욱 중요하며 수전 단에 설치되는 과전류 계전기의 보호협조 주요항목은 다음과 같습니 다. 1) 수용가내의 계통에 있어서 단락및 과부하의 정도에 따라 정확히 동 작 하여야 하며 전후단 계전기와 적절한 동작시간을 설정하여 사고 파급을 최소화 해야한다. 2) PF CB형의 경우에는 PF(한류FUSE)와 CB(차단기)와의 책무 분담 이 적절하여야한다. (PF의 용량 및 CB의 차단기 용량 선정) 3) 위의 계통에 있어서 배전변전소 OCR과의 동작협조가 취해 져야 한다(OCR의 관성특성이나 차단기의 차단시간을 고려할 것.) 4) 수용가 내의 분기 OCR과의 동작협조가 되어야 한다. 5) 저압측 사고에 따라 수전단 OCR이 동작하지 않도록 저압축 MCC (배선용 차단기)와의 동작 협조가 되어야 한다. 6) OCR의 한시요소의 동작 시간은 부하 변압기의 열특성 곡선을 넘 어서는 안된다. 7) 사고시에 변압기, 차단기, CABLE, CT등의 기기는 단락 강도나 과 부하 용량에 충분히 견디어야 한다. 8) CT의 선정은 과전류 정수와 BURDEN을 고려하여 선정할것. �Application diagram for relay Protective coordination In general, relays being used in power system should be a function of protective coordination including over current relay, The major items of protective coordination for over current relay are as following 1) On receiving system, the relay should be operated surely at short circuit and over load, and detected the fault point and responded currently against the fault current of impedance. 2) In case of P. F type and C. B type, 2 types should be charge of it's respective role appropriately (selection of P. F capacity and C. B capacity) 3) In above system, the relay should be operated on coordination with OCR in distribution substation. 4) The relay should be operated on coordination with OCR in feeder distribution line. 5) should be operated on coordination with MCCB of low voltage side so that OCR of receiving line should not be operated due to fault of low voltage side. 6) The operating time of definite O. C. R element should not excess feet characteristic curve of load transformer. 7) When it occures fault, the equipments : transformer, breaker, cable etc should be endured short circuit strength or over load suffitiently. 8) When there are to select for relay, please consider of burden and over current constant for C. T �Protective coordination DEESYS TOTAL PRODUCTS GUIDE 187 Induction type Over Current Relay[OCR] 50/51 Features 특징 과전류 계전기는 과부하 및 단락 사고시 동작하는 계전기로서 과부하 고장은 한시요소(ICS)가 동작 및 표시하고 단락 사고 및 대전류가 인 입시는 순시요소(IIT)가 동작 및 표시하여 사고의 크기에 따라 적절히 대응하여 보호하고 사고유형을 파악하기 용이하도록 설계 되었습니다. 1) 배전단 OCR(DCO형)과 수전단 OCR(DOC형)을 그림3, 4 와 같이 구분하여 배전단과 수전단과의 보호협조를 용이 하도록 제작하였 습니다. 2) 진동 및 충격등의 오동작 방지를 위하여 a) 회전부(원판)를 광각형으로 설계 주접점(원판접점)의 간격을 최대화 하였습니다. b) 회전부 원판의 PIVOT와 축수석을 특수설계하여 충격 진동에 의해 이탈 및 파손 되는 것을 방지하였습니다. c)회전부 원판의 마찰을 극소화 하였습니다. 3) 부품의 정밀화로 기기의 신뢰성을 향상시켰습니다. 4) 설치 취급시 기존 계전기와 동일하게 사용토록 규격화하여 편리 하게 사용할 수 있습니다. 5) 동작 표시기는 순시( 약 20ms)으로 동작되며 황색표시(Munsell No.2 5yr 6/13)로 사고 판별이 용이합니다. For DCO type characteristic of protective coordination 188 DEESYS TOTAL PRODUCTS GUIDE Over current relay(O. C. R) is operated on overload and short circuit. This relay has two elements : one is definitive element for operating and indicating on fault of overload, the other is instantaneous element for operating and indicating in rush current on fault of short circuit. And then this relay is designed that it is easy to detect a reason of fault and to response to what fault is some trouble. 1) As diagram 3 & 4, this relay is two types : one type is DCO type for distribution, the other type is DOC type for receiving. These two types will be good coordination for protective system of line. 2) For protection of misoperation on some shock, impact & inspection a) The rotating port (round type disk) is designed wide angle type and the distance of main contact (the contact of round type disk) is long. b) The pivot and main post of rotating round type disk are designed specially and it will protect them from seperation and damage the to some shock or impact. c) Minimization the friction of round type disk. 3) Improvement of reliablity of the relay the to precision of all parts 4) Because this relay is manufactured and standardized some typical type, it is easy to use the relay and change the relay installed in panel to a new relay 5) The operating target will be operated instantaneous (about 20ms)and it is easy to distinguish to fault according to the operating target color. (when it is fault, the target color will be yellow) For DOC type characteristic of protective coordination Induction type Over Current Relay[OCR] 50/51 Specification �ICS coil impedance Rating Coil Ressistance(Ω) 0.81/0.16 1.0/0.17 32/0.85 0.15/0.65 36 0.27 300 1160 1310 2260 2.0 0.62 0.65 5000 18000 0.2A/2.0A 0.5A/2.0A 0.1A/1.0A 0.5A/1.0A 0.1A 1.0A 24V 110V 125V 220V 0.5A 1.0A 2.0A 110V 220V D.C A.C Operating Value 70-90% of tap value �DCO Type Time Characteristics Rating Type Model No NonDrawout DCO-A Drawout DCO-A Inverse Very Inverse NonDrawout DCO-A Drawout DCO-A NonDrawout DCO-B Drawout DCO-B NonDrawout DCO-B Drawout DCO-B C4 C3 C2 C D4 C D3 C D2 CI 4 CI 3 CI 2 CID 4 CID 3 CID 2 C4 C3 C2 C D4 C D3 C D2 CI 4 CI 3 CI 2 CID 4 CID 3 CID 2 A Hz 5 3 5 3 60Hz 5 3 5 3 5 3 5 3 60Hz 5 3 5 3 Tap Range (A) 4-12 3-9 2-6 4-12 3-9 2-6 4-12 3-9 2-6 4-12 3-9 2-6 4-12 3-9 2-6 4-12 3-9 2-6 4-12 3-9 2-6 4-12 3-9 2-6 IIT Unit (A) Burden (VA) 20-80 20-80 20-80 20-80 20-80 20-80 10 8 12 10 8 12 10 8 12 10 8 12 10 7 12 10 7 12 10 7 12 10 7 12 IIT Unit (A) Burden (VA) 20-80 20-80 20-80 20-80 20-80 20-80 5.0 7.0 4.0 5.0 7.0 4.0 5.0 7.0 4.0 5.0 7.0 4.0 20-80 20-80 20-80 20-80 20-80 20-80 Operating Burden ICS 5.5 5.0 4.0 5.5 5.0 4.0 5.5 5.0 4.0 5.5 5.0 4.0 5.5 5.0 4.0 5.5 5.0 4.0 5.5 5.0 4.0 5.5 4.0 5.0 ICS+IIT 12 14 24 12 14 24 12 14 24 12 14 24 ICS Unit (DC A) Weight (Kg) 1.0 3.0 0.5/2.0 0.1/1.0 4.0 1.0 3.0 0.5/2.0 0.1/1.0 4.0 1.0 3.0 0.5/2.0 0.1/1.0 4.0 1.0 3.0 0.5/2.0 0.1/1.0 4.0 ICS Unit (DC A) Weight (Kg) 1.0 3.0 0.5/2.0 0.1/1.0 3.8 1.0 3.0 0.5/2.0 0.1/1.0 3.8 �DOC Type Time Characteristics Very Inverse Rating Type Model No NonDrawout DOC-B Drawout DOC-B NonDrawout DOC-B Drawout DOC-B *DOC-B : Very Inverse C4 C3 C2 CD4 CD3 CD2 CI4 CI3 CI2 CID4 CID3 CID2 *2-6:2-2.5-3-3.5-4-5-6 A Hz 5 3 5 3 5 3 5 3 60Hz Tap Range (A) 4-12 3-9 2-6 4-12 3-9 2-6 4-12 3-9 2-6 4-12 3-9 2-6 *3-9:3-4-5-6-7-8-9 Operating Burden ICS 2.8 2.0 1.8 2.8 2.0 1.8 2.8 2.0 1.8 2.8 2.0 1.8 ICS+IIT 9 12 14 9 12 14 *4-12:4-5-6-7-8-10-12 DEESYS TOTAL PRODUCTS GUIDE 189 Induction type Over Current Relay[OCR] 50/51 DCO-LA Type (Long time OCR) For motor protection Time Characteristics Inverse Type Model No NonDrawout DCO-LA Drawout DCO-LA A CI CI CI CI CI CI 4 3 2 D4 D3 D2 Rating Hz 5 3 60Hz 5 3 Tap Range (A) 4-12 3-9 2-6 4-12 3-9 2-6 IIT Unit (A) Burden (VA) 20-80 20-80 20-80 20-80 20-80 20-80 4 5 6 4 5 6 Operating Burden ICS ICS+IIT 4.8 6.0 7.2 4.8 6.0 7.2 9 12 14 9 12 14 ICS Unit (DC A) Weight (Kg) 1.0 3.0 0.5/2.0 0.1/1.0 4.0 *DCO-LA : Long Time Inverse Specification [JEC 2510 Application] Item Definitive element (ICS) Instantaneous element (IIT) Operating Value below ±5% of each setting value Resetting Value on time Lever 10. over 90% of minimun current setting value DCO-B Operating time very Inverse OPERATING TIME DOC-B TIME OVER CURRENT (SEC) LEVER 300% 500% 1000% #10 5.0 2.3 1.4 #7 3.5 1.6 0.98 #4 2.0 0.92 0.56 #10 4.0 1.6 0.76 #7 2.8 1.12 0.53 #4 1.6 0.64 0.3 below± 10% of each setting value TIME ERROR (%) 300% 500% 1000% ±12 ±7 ±7 ±10 ±6 ±6 ±8 ±5 ±5 ±12 ±7 ±7 ±10 ±6 ±6 ±8 ±5 ±5 over 10% of minimun current setting value below 40mS in input 200% inertia current setting minimun time setting 1000% of tap #10 value operating time : over 80% of nominal characteristics operating time temperature below ±20% in -20℃ ~ +60℃ (operating time : measuring in 300 % of input current) characteristics overload Two times during 0.25 second in twenty times (100A) of rated current characteristics (operating value and time : minimun tap) Vibration In case of two times of vibration to each direction 4 front and left. above and below) in frequeney characteristics 16.7hz. with 0.4mm in condition of 80% value of minimun seifty operating current. all part of relay should be good Impacting characteristics Insulation resistor Dielectric voltage In case of impacting two times 30g weight to allparts. all parts of relay should be good over 10MΪ by DC 500V Megger in condition of all circuit to cubicle, contact to contact. and circuit to circuit AC 2000 1 minute common frequency in condition of all circuit to case. circuit to circuit AC 1000 1 minute common frequency in condition of contact to contact Main Contact AC 220/10A contact capacity AC 110/15A Contacting time : 0.5 sec 190 DEESYS TOTAL PRODUCTS GUIDE Induction type Over Current Relay[OCR] 50/51 Time & Curve Characteristics �Inverse �Very inverse DCO-A DCO-B For incoming �Very inverse �Instantaneous OperatingTime Characteristics (IIT) DOC-B DEESYS TOTAL PRODUCTS GUIDE 191 Induction type Over Current Relay[OCR] 50/51 Time & Curve characteristics ● Long time inverse(장반하시) ● How to setting the relay �definitive current setting The relay will be set about 150% current of contract power according to the current transformer ratio TAP ≒ X5 1 CT X 1.5 TAP = setting tap of relay 1 = current value of contract power CT = primary rating current of CT (secondary current is 5A) 순시전류정정 변압기의 도입여자전류로 오동작하지 않도록 변압기 용량에서 계산되는 전류치의 1,000~1,500%로 조정합니다. TAP ≒ 1 X5 CT X 10~16 TAP = 계전기의 정정탭 1 = 변압기의 용량(KVA)에 의해계산된 전류치 CT = CT의 1차 정격전류 (2차 전류는 5A) Error caculation for operating time of deffinitive element tNError= ● TRIP부 전류 증가방법 계전기 동작(TRIP)시 ICS(동작표시기겸 보조접촉기)를 확실하게 동 작 시키기 위해 ICS 정격의 2~3배의 전류가 흐를수 있도록 차단용 AUX. RELAY 또는 52TC 의 임피던스를 적절히 조정할 필요가 있 습니다. 도 9-1과 같이 Coil과 병렬로 저항(R)을 접속하여 ICS에 흐르는 전 류를 조정합니다. 예) TC=1.5A DC110v의 경우 그림 9-1과 같이 Relay 2대가 동시 에 동작되는 사례도 발생됩니다. 따라서 저항 R값을 정격으로 사용하십시오. 110V R= =27.5�25Ϊ, 100W 2A×2 ● How to increase current of trip coil(ICS) On operating the relay(Trip), the impedance of Aux Relay or 52TC should be adjusted in order to operate the ICS (operating target and Aux contact) according to conducting more 2~3 times current than rated ICS current. As diagranm 9-1, it can be adjusted the current of ICS with connecting a resistor and the 52TC coil in parrallel circuit Ex) In case of TC=1.5A, DC 110V, 2 sets of relay connecting as diagram9-1. The value of resistor as following. R= 192 110V 2A×2 =27.5�25Ϊ, 100W DEESYS TOTAL PRODUCTS GUIDE N 10 × t10 T10 ×100(%) T10 : Rating operating time tN : measuring operating time of operating time lever(n) N : Locating of operating time lever(tap) ● How to increase current of trip coil Fig 9-1 Induction type Ground Over Current Relay[OCR] 50/51N DCG/DOG type DCG/DOG형 지락과전류 계전기는 소세력 유도원판형으로서 주로 변류기 의 잔류회로에 사용되며 지락 및 단락사고 보호용으로 사용된다. DCG/DOG type ground over current relay is induction rotary disk type that is operated in remained circuit current of current transformer. Specification Time Characteristics Very Inverse Rating Type Model No A Hz Tap Range (A) IIT Unit (A) Burden (VA) Operating Burden ICS ICS+IIT ICS Unit (DC A) Weight (Kg) 12 2.5 20 1.0 3.0 12 2.5 20 0.5/2.0 0.1/1.0 4.0 NonDrawout DCG-B CI 5 Drawout DCG-B CI D5 NonDrawout DOG-B CI 5 6.5 1.6 7 1.0 3.0 Drawout DOG-B CI D5 6.5 1.6 7 0.5/2.0 0.1/1.0 4.0 *0.5-2.5:0.5-0.6-0.8-1.0-1.5-2.0-2.5 1 60 0.5/2.5 10-40 *10-40:10-20-30-40 Time & curve characteristics �Very inverse(For distribution) �Very inverse(For receiving) DCG-B DOG-B DEESYS TOTAL PRODUCTS GUIDE 193 Induction type Ground Over Current Relay[OCR] 50/51N Internal connection diagram(ICS current type) �Drawout type �Non drawout type External connection diagram (fig 13) 194 DEESYS TOTAL PRODUCTS GUIDE Induction type Over, Under, Ground Voltage Relay[59] [27] [64] DOV/DUV type DOV, DUV형 전압계전기는 교류회로의 이상전압을 검출하여 송배전선과 기기의 손상을 방지하는 단상 유도 원판형 전압계전기입니다. DOV, DUV type voltage relay is induction rotary disk type and protects the power and distribution line & equipments from abnormal voltage of AC circuit. Features 1. JEC-174B규격에 적용 제작 되었습니다. 2. 주파수 및 주위 온도 변화에 따른 오차폭이 작습니다. 3. D형은 내부인출의 구조로 되어 있어 외부에서의 보수 및 시험이 가능합니다. 1. It is applied JEC-174B standard 2. According to variable frequency and temperature, the error of relay is very little 3. D type relay is drawout type and it's maintanence and testing is very easy in outside. Specification �OVR, OVGR Item Operating value Resetting vlaue Operating value Self temperature rising characteristics Temperature characteristics Overload withstand Vibration characteristics Shock characteristics Insulation characteristics Withstand voltage Contact capacity �UVR DOV type over voltage relay(OVR, OVGR) ±5%of setting tap above 90% of operating value in minimum tap (OVGR;80%) Min voltage tap at lever #10 Input 120% 130% 150% Operating time(SEC) 26.6 ± 20% 17.7 ± 18% 9.84 ± 15% Refer to characteristics wave of tested operating time(Fig14) At min tap Lever#1 The operating erro between normal condition and self temperature rising condition will be ±5% of setting tap value 1. operting value:Min TAP.Lever #1 -10℃, 50℃ Error ±10% 2. operating time:MinTAP, Lever #10 Input 120% 130% 150% Operating time(SEC) 26.6 ± 30% 17.7 ± 37% 9.84 ± 32% (Applied JEC174B) DUV type under voltage relay(UVR) ±5% of setting tap below 110% of operating value in maximum tap Max. voltage tap at lever #10 Input 80% 0% Operating time(SEC) 20.7 ± 20% 7.4 ± 18% Refer to characteristics wave of tested operating time(Fig15) The operating error will be ±5% of setting tap value 1. operting value:Min TAP.Lever #1 -10℃, 50℃ Error ± 7% 2. operating time:MinTAP, Lever #10 Input 80% 0% Operating time(SEC) 20.7 ± 30% 7.4 ± 15% At min tap, 1.15 times 3 hours of rating voltage In case of 10 minutes of vibration to each direction front and back, left and right, above and below in frequency 16.7㎐ with 0.4㎜ in condition of min tap, lever #1 110% of DOV type relay setting values 90% of DUV type relay should be good In case of impacting 30g weight to all partsuf relay, all parts of relay should be good All circuit to case : over 10㏁/500V Megger circuit to circuit : over 10㏁/500V Megger contact to contact : over 10㏁/500V Megger All circuit to case : AC 2000V/1 minute circuit to circuit : AC 1000V/1 minute contact to contact : AC 1000V/1 minute Main contact : AC 110V 5A AC 110V 10A ICS contact : AC 110V 10A AC 110V 5A DEESYS TOTAL PRODUCTS GUIDE 195 Induction type Over, Under, Ground Voltage Relay[59] [27] [64] Over voltage relay(OVR) Rating Model No NON-DRAWOUT DOV DRAWOUT DOV V Hz C1 110 C2 220 CD1 110 CD2 220 60 60 Tap Range Burden Operating Burden (V) (VA) MIn(VA) Max(VA) 110-115-120-125-130-140-150 2.0 1.6 1.6 220-230-240-250-260-280-300 2.0 1.6 1.6 110-115-120-125-130-140-150 2.0 1.6 1.6 220-230-240-250-260-280-300 2.0 1.6 1.6 ICS Unit Weight (DC A) (㎏) 1.0 2.7 0.5/2.0 0.1/1.0 3.5 Under voltage relay(UVR) Rating Model No V NON-DRAWOUT DOV C16 110 C26 220 DRAWOUT DOV CD16 110 CD26 220 Hz 60 60 Tap Range Burden (V) (VA) MIn(VA) Operating Burden Max(VA) 60-65-70-75-80-85-90 6.0 1.6 1.6 160-165-170-175-180-185-190 4.0 1.6 1.6 ICS Unit Weight (DC A) (㎏) 1.0 2.7 60-65-70-75-80-85-90 6.0 1.6 1.6 0.5/2.0 160-165-170-175-180-185-190 4.0 1.6 1.6 0.1/1.0 Tap Range Burden (V) (VA) MIn(VA) Max(VA) 20-25-30-35-40-45-50 35 0.8 0.8 35-40-45-50-55-60-65 40 0.8 0.8 20-25-30-35-40-45-50 35 0.8 0.8 0.5/2.0 35-40-45-50-55-60-65 40 0.8 0.8 0.1/1.0 3.5 Over voltage ground relay(OVGR) Rating Model No V NON-DRAWOUT DVG C1 110 C9 190 DRAWOUT DVG CD1 110 CD9 190 Hz 60 60 Operating time characteristics curves 196 DEESYS TOTAL PRODUCTS GUIDE Operating Burden ICS Unit Weight (DC A) (㎏) 1.0 2.7 3.5 Induction type Over, Under, Ground Voltage Relay[59] [27] [64] Internal connection diagram �Drawout type �Non draw out type External connection diagram DEESYS TOTAL PRODUCTS GUIDE 197 Induction type Directional[Selective] Ground Relay [67] DSG type DSG형 방향지락 계전기는 비접지 계통의 고압배전 및 수전단의 지락 보호용으로 사용되며 보호구간내에 cable과 대지간 충전전류가 클 경 우(예:cable이 길때) 에 적용됩니다. 모선(Main)에서 나와있는 다수의 회선중 사고 회선만 선택 판별하여 차단시켜 정전사고 파급을 최소화 할수 있습니다. ※ 접지 변압기 (GPT:3’ry 190 or 110V)및 영상 변류기 ※ (ZCT:200/1.5mA) 조합하여 사용하십시오. 본 catalog 191page 참고 ※ 본 계전기는 고감도형으로 배전반의 진동과 충격에 의해 오동작 할 수 있습니다. 따라서 진동, 충격이 발생 할 수 있는 장소에서 는 DVG형 OVGR과 조합하여 사용하십시오. DSG type directional ground relay will be used for ground fault protection of high voltage distribution and receiving line in non-grounding system. In case of discharging much current between cable and earth in portection area, this relay will be applied. This relay will select the fault line among many feeder lines of main bus and shut down the fault line. And then the fault will be minimum �Ground transformer (GPT 3ry 190V or 110V) and zero phase current transformer(ZCT:200/1.5㎃)should be used for coordination. �This relay may be misoperated by vibration and impact of switchgear because it is very precious. �In condition of being used in place of happening vibration and impact, it should be used with over of DVG type. Specification �SGR Type Model No Drawout DSG Drawout Non- DSG Rating Zero Phase Zero Phase Voltage(V) 1’ ry current CD 1 110 CD 9 190 C 1 110 C9 190 Operating Current 150㎃ 200(㎃) Burden 34 36 Voltage:190V, Current:200㎃ 34 Phase angle:LEAD37。 36 ICS Unit (DCA) Weight (Kg) 0.5/2.0 4.5 1.0 3.5 Phase angle characteristics ※ 유도형 SGR 계전기에 사용되는 ZCT는 반듯이 ZT 형을 사용하십시요.(영상변류기 200mA/1.5mA) 198 DEESYS TOTAL PRODUCTS GUIDE Induction type Directional[Selective] Ground Relay [67] Internal connection diagram (ICS current Type) �Drawout type �Non draw out type Connection diagram Connection diagram DEESYS TOTAL PRODUCTS GUIDE 199 How to Drawout Name of parts How to drawout A,B) release the cover handle of. C) Take over the dwawout pin located in each side of case. D) Take out drawout socket. 200 DEESYS TOTAL PRODUCTS GUIDE E) take out the relay unit with drawout pin smoothly F) The relay unit will be seperated from the case ※ for assembling the relay, please reverse the process Dimension Dimension �Induction protective relay Cutting Size : 154 x 184mm DEESYS TOTAL PRODUCTS GUIDE 201 KS C 1303 JIs C 1102 Panel Board Meter ■Panel Board Meter ■Panel Board Factor Meter [cosφ ] ■Panel Board Meter [DIN Type] ■Panel Board Frequency Meter(Vo) ■Panel Board Ampermeter ■Panel Board Maximum Demend Meter ■Panel Board Voltmeter ■3Phase Square Type Selction Meter[A,V] ■Panel Board Wattmeter ■Digital Paner Board Meter ■Panel Board varmeter 판넬용 지지전기계기(각형, 광각형) DEESYS TOTAL PRODUCTS GUIDE 203 KS C 1303 Panel Board Meter Characteristics ● 주위환경에 대해 높은 신뢰성이 있습니다. ● 판넬에 취부가 용이하도록 설계하였습니다. ● 계기는 PIVOT 형으로 광각형은 80X80mm , 110x110mm, 각형은 80 x 80mm, 100x 84mm가 있습니다. ● 외부 자계의 영향을 받지 않습니다. ● 광각형 메타 전면 카바를 광각의 효율을 배가시키기 위하여 카바 돌출부를 특수하게 제작 명판 눈금 표시사항 및 지침 상태를 선명 하게 볼수 있도록 제작되었습니다. ● 계기의 외함 조립 부분을 볼트인써트화하여 기존계기보다 견고히 제작 장수명화 하였습니다. ● 단자에 보호커버를 설치하여 안전사고에 만전을 기했습니다. � High reliability for surrounding environments � Suitable designation to be installed on the panel. � It in pivot type. and the size of wide angle type is 80×80mm. 110×110mm and the size of square type is 80×80mm. 100×84mm � No influence for magnetic force of outstanding. � This meter in manufactured specially the front cover to increase effect of the wide angle and if in very easy to find out indicating and locating of the needle due to manufacturing specially the top of cover � As assembling the case with incerting some bolts. if in longer life than the other meter Ordering procedure W : 광각형 (Wide Angle Type) S : 각형 (Square type) 8:80mm×80mm 11:110mm×110mm 8:80mm×80mm 10:100mm×84mm *7:72mm×72mm *4:48mm×48mm A: Ampere V: Volt W: Watt P: Power Factor(cosφ ) F: Frequency (Hz) R: Reactive power (var) *DIN SIZE Double Scale 눈금경우 외측이 흑색 내측 눈금이 적색으로 표시됩니다. 204 DEESYS TOTAL PRODUCTS GUIDE A: AC D: DE 1: 1P 2W 2: 1P 3W 3: 3P 3W 4: 3P 4W U: Unbalance B: Balance T: Transducer (INT type) M: Meter Relay Panel Board Meter Type division equipment Amperemeter & Voltmeters DC W8/S8 Type Model Class Model W8-AD 1.0% W11-AD W8-VD 1.5% W11-VD 2.5% S4.7-AD,VD Moving Coil type S8-AD S8-VD Operating method class 1.0 or 1.5% S10-AD Moving Coil Type 1.5% S10-VD W8-AA Rectifier Type W8-VA Amperemeter & Voltmeters W11/S10 Type Operating method S8-AA Moving lron Type 1.0% W11-AA 1.5% W11-AA S4.7-AA 2.5% S10-AA Rectifier Type 1.0 or 1.5% Moving Coil Type 1.5% Rectifier Type 1.5% S4-VA S8-VA Rectifier Type 2.5% S7-VA S10-VA AC W8-W Watt Meters(W) Transducer Type S8-W W8-R Var Meters(var) Power Factor (cosφ ) Meters Frequency Meters W8-F W11-W 2.5% S10-W 1.5% W11-R 2.5% S10-R Transducer Type S8-R W8-P 1.0%,1.5% S8-P S8-F Transducer Type 5.0% Transducer Type 1.0% 1.5% 1.0%,1.5% Transducer Type W1-P 1.5% 3.0%,5.0% Transducer Type S10-P W11-F 5.0% Transducer Type S10-F ※ 1.0%,1.5% Transducer Type 1.0% EXT Transducer Type / INT Transducer Type Standard specification Scale Type W8/S8 Type Scale Length(㎜) W11/S10 Type 122/68 176/80 Number of Division 24~52 Angle of Deflection 250。 / 90。 meterial : Case/Cover ABS Resin/Poly cabonate Resin colour : Case Munsell n1.5 (black), Munsell 7.5(blue-gray) Name Plate White Position of Use Vertical(⊥) Standard Pointer “W”Type Standard Ambient Temperture “S” Type Standard 0℃~ 40℃ Full scale formats of“W”type Full Scale 1 1.2 1.3 1.4 1.5 2 2.4 2.5 3 3.8 4 4.5 4.8 5 6 5.2 7.5 8 9 31.2 1.6 Divisions 50 24 26 28 30 40 48 50 30 38 40 45 48 50 30 52 37.5 40 45 31.2 32 ※ Actural full scale in the value of 10n times of table value. Full scale formats of“S”type Full Scale 1 1.2 1.5 2 2.4 2.5 3 4 4.5 5 6 7 7.5 Divisions 20 24 30 20 24 25 30 20 22.5 25 30 35 37.5 ※1 7.5 8 15 40 ※2 8 16 ※3 9 45 ※ Actural full scale in the value of 10n times of table value. ※ Remark ※1.2 in applicated for S8 type ※ Remark ※3 is applicated only for type S10 � The standard scale of power factor meter (cos�) � The standard scale of frequency meter(Hz) is indicated 45~55 and 55~66. DEESYS TOTAL PRODUCTS GUIDE 205 Panel Board Meter[DIN type] S7 type S4 type Specification Type Size S4-AA S4-VA 48X48mm Rating Freq(Hz) AC 5A 50/60 Moving lron 1.5VA 0.15 AC 150,300V 50/60 Rectfier 0.7VA 0.15 S4-AD DC50mV,1mA S7-AA AC 5A 50/60 Rectifier AC150,300V 50/60 Rectifier S7-VA 72X72mm S7-AD S7-F - Principle Class Moving Coil 1.5 Burden Weight(Kg) DC 1mA,50mA 0.15 1.5VA 0.22 0.7VA 0.18 DC50mV, 1mA - Moving Coil DC 1mA, 50mV 0.18 45~70Hz - Transducer 2.0VA 0.3 ※ 주문시 Hz 선택 특징 Features 1. Motor 회로에 사용시 기동전류를 감안하여 정격 전류치의 150~300%에 해당하는 초과눈금 계기를 사용하십시오. 2. 선로전압(측정대상 전압)이 300V를 초과 할시는 계기용 PT를 조합 하여 사용하십시오. 3. Panel 에 취부하기가 편리합니다. ■ S7형은“ㄷ” 형 Band를 이용 Nut로 조여 취부합니다. ■ S4형은 판 Spring (SUS)이 부착되어 있어 CUT부위에 밀어 넣 으면 간단히 취부됩니다. Dimension 206 DEESYS TOTAL PRODUCTS GUIDE 1. Select the 150~330% over scale meter of rating current due to starting current of motor if it is used in motor circuit. 2. Combine the P.T for meter if the voltage of circuit (Measuring voltafe) is over 300V 3. It is very easy to install the meter on panel ■ In case of S7 type. it can be installed by ㄷ type band. ■ In case of S4 type. if can be installed easing by pushing on the cut hole with plate spring (SUS) Panel Board Ampere Meter “W”type “S”type Specification Type W8-AA W8-AD W11-AA W11-AD S8-AA S8-AD S10-AA S10-AD Size 80X80mm 110X110mm 80X80mm 100X84mm Rating Freq(Hz) VA 5A 50/60 1.5 50mV - 50mV Drop 5A 50/60 1.5 50mV - 50mV Drop 5A 50/60 1.5 50mV - 50mV Drop 5A 50/60 1.5 50mV - 50mV Drop Class Weight(Kg) 1.0 or 1.5 0.40 1.0 or 1.5 0.52 2.5 0.25 1.5 0.27 ※ 주문시 Hz 선택 특징 Characteristics ●AC Amperemeter 1. 전류가 5A를 초과할 경우에는 정격 2차 전류가 5A(1A) 인 계기 용 변류기(C.T)를 조합하여 사용하십시오. 2. 회로전압이 500V를 초과하고 전류가 5A 이하인 회로의 경우에 도 확실한 절연을 위해 계기용 변류기를 조합하여 사용하십시오. 3. 전동기 사용시 전류계의 Full Scale를 Motor의 기동전류를 감안 하여 정격전류치의 150~500%에 해당하는 초과눈금 계기를 사 용하십시오. (초과 눈금의 오차는 ±10%입니다.) ●DC Amperemeter 1. 30A 이하인 전류에서는 자체 Meter에 분류기(Shunt)가 내장되 어 있어 필요없으나 30A 이상의 전류에서는 외부에 Shunt(50mV)를 연결하여 사용하십시오. 2. Shunt 결선시 마이너스(-)측에 설치하십시오. ■ AC Amperemeter 1. Combine C.T of rating 2ry current 5A(1A) for meter if current of case it in over 5A 2. Combine P.T & C.T for meter in order to insulate the circuit if voltage of circuit over 500V and current of circuit is below 5A. 3. Select 150~500% over scale meter of rating current due to starting current of motor if it in for motor circuit. ■ DC Amperemeter 1. In case of below 30A current. the shunt installed in the meter. But in case of over 30A current. the shunt in not installed in the meter. please connect the shunt (50mA) outside. 2. When you connect the shunt. connect the shunt on the minus side. External connection diagram ■ AC Ammeter ■ DC Ammeter DEESYS TOTAL PRODUCTS GUIDE 207 Panel Board Volt Meter “W”type “S”type Specification Type W8-VA W8-VD W11-VA W11-VD S8-VA S8-VD S10-VA S10-VD Size 80X80mm 110X110mm 80X80mm 100X84mm Rating Freq(Hz) VA 150, 300V 50/60 0.5 150, 300V - 1KΩ/V 150, 300V 50/60 0.5 150, 300V - 1KΩ/V 150, 300V 50/60 5.0(0.5) 150, 300V - 1KΩ/V 150, 300V 50/60 5.0(0.5) 150, 300V - 1KΩ/V ※ VA: AC, VD: DC, W:Wide Angle Types, S: Square Type ※ The value of ( ) in for rectifier type Class Weight(Kg) 1.0 or 1.5 0.33 1.0 or 1.5 0.45 2.5 0.18 1.5 0.20 ※ 주문시 Hz 선택 Characteristics ●AC Voltmeter 1. 입력전압이 AC 300V이상의 회로에는 150V전압계를 P.T와 조 합하여 사용하십시오.(600V 전압계는 주문에 의함) 예) meter scale 0~9.000V. Input range 0~150V P.T ratio 6.600/110V ■ AC Meter 1. Combine P.T with 150V meter if input voltage in over AC 300V circuit. EX) meter scale 0~9000V. input range 0~150V P.T ratio 6.600/110V ●DC Voltmeter 1. 입력전압이 DC 750V 이상의 경우에는 외부 배율기를 부착 사용 하십시오. 2. 배율기는 (+)측에 결선 하십시오. 3. DC Voltmeter의 전류감도는 1mA(1KΩ/V)입니다. ■ DC Meter 1. Connect the multiplier outside in case of over DC 750V of input voltage. 2. Connect the multiplier on pluse side. 3. The current sensitivity of DC voltmeter in 1mA (1KΪ/V) Ex) Choose of Meter ex1) 3P 3W (In case of 6.6KV line) full scale value (V):9KV P.T ratio:6.6KV/110V 9KV MAX. input range= =150V 6.6KV/110V ex) 3P 4W (In case of 22.9KV line) full scale value (V):31.2KV P.T ratio:22.9KV/110V 31.2KV MAX. input range= =150V 22.9KV/110V External connection diagram ■ DC Voltmeter 208 DEESYS TOTAL PRODUCTS GUIDE ■ AC Voltmeter Panel Board Watt Meter “W”type “S”type Specification Type Size Circuit W8-W2 (wide angle) W8-W3 80×80㎜ W8-W1 Rated VA Remark Weight Hz Class - 60 1.5 0.65 - 60 1.5 0.75 EXT. T/D V A V A V A 1P2W 110,220 5 0.5 0.5 - 1P3W 110 5 0.5 0.5 - (㎏) REF 3P3W 110,220 5 0.5 0.5 B U 60 1.5 0.75 3P4W 190/ √ 3, 380/ √ 3 5 0.5 0.5 B U 60 1.5 0.85 W8-W4U 3P4W 190/ √ 3, 380/ √ 3 5 0.5 0.5 U U 60 1.5 0.90 W11-W1 1P2W 110,220 5 0.5 0.5 - - 60 1.5 0.70 W11-W2 1P3W 110 5 0.5 0.5 - - 60 1.5 0.85 EXT. W11-W3 3P3W 110, 220 5 0.5 0.5 B U 60 1.5 0.85 T/D W8-W4 W11-W4 (wide angle) 3P4W 190/ √ 3, 380/ √ 3 5 0.5 0.5 B U 60 1.5 0.95 W11-W4U 110×110㎜ 3P4W 190/ √ 3, 380/ √ 3 5 0.5 0.5 U U 60 1.5 1.00 W11-W1T 1P2W 110, 220 5 0.5 0.5 - - 60 1.5 0.60 W11-W2T 1P3W 110 5 0.5 0.5 - - 60 1.5 0.85 INT. W11-W3T 3P3W 110, 220 5 0.5 0.5 B U 60 1.5 0.85 T/D W11-W4T 3P4W 190/ √ 3, 380/ √ 3 5 0.5 0.5 B U 60 1.5 0.90 W11-W4UT 3P4W 190/ √ 3, 380/ √ 3 5 0.5 0.5 U U 60 1.5 0.90 S8-W1 1P2W 110,220 5 0.5 0.5 - - 60 1.5 0.55 S8-W2 (Square type) 1P3W 110 5 0.5 0.5 - - 60 1.5 0.65 EXT. S8-W3 80×80㎜ 3P3W 110,220 5 0.5 0.5 B U 60 1.5 0.65 T/D S8-W4 3P4W 190/ √ 3, 380/ √ 3 5 0.5 0.5 B U 60 1.5 0.75 S8-W4U 3P4W 190/ √ 3, 380/ √ 3 5 0.5 0.5 U U 60 1.5 0.85 S10-W1 1P2W 110,220 5 0.5 0.5 - - 60 1.5 0.57 S10-W2 (Square type) 1P3W 110 5 0.5 0.5 - - 60 1.5 0.67 EXT. S10-W3 100×84㎜ T/D 3P3W 110, 220 5 0.5 0.5 B U 60 1.5 0.67 S10-W4 3P4W 190/ √ 3, 380/ √ 3 5 0.5 0.5 B U 60 1.5 0.77 S10-W4U 3P4W 190/ √ 3, 380/ √ 3 5 0.5 0.5 U U 60 1.5 0.87 ※U:Unbalance, T:Int. Transduce, W:Watt. ※EXT.T/D:Installation the Transducer outside, INT.T/D:Installation the transducer inside ※The specification of rating current 1A is based on ordering � EXT. Watt meter ※ 주문시 Hz 선택 �EXT. T/D DEESYS TOTAL PRODUCTS GUIDE 209 Panel Board Watt Meter Standard full scale table(Watt meters) Phase Wire 1P2W 1P3W P.T.ratio(V) 110 110 220 380 /110 440 /110 3300 /110 6600 /110 22000 /110 22900 /110 0.6㎾ 1.0㎾ 2.0㎾ 1.158㎾ 1.0㎾ 1.0㎾ 1.0㎾ 1.0㎾ 0.961㎾ 1.0㎾ 2.0㎾ 2.0㎾ 4.0㎾ 1.666㎾ 1.666㎾ 0.6 1 2 4 4 30 60 200 200 1400 2 4 4 100 200 C.T.ratio Calibrating watts 5/5 3P3W 3P4W 154㎾ 208/ 3 380/√ √ /190/√33 /110 380 11400/ √ 3 22900/ √ 3 /√ 3 /190/√ 3 /190/√ 3 10/5 1.2 2 4 8 8 60 120 400 400 2800 4 8 8 200 400 15/5 1.8 3 6 12 12 90 180 600 600 4200 6 12 12 300 600 20/5 2.4 4 8 16 16 120 240 800 800 5600 8 16 16 400 800 25/5 3.0 5 10 20 20 150 300 1000 1000 7000 10 20 20 500 1000 30/5 3.6 6 12 24 24 180 360 1200 1200 8400 12 24 24 600 1200 40/5 4.8 8 16 32 32 240 480 1600 1600 11.2㎿ 16 32 32 800 1600 50/5 6.0 10 20 40 40 300 600 2000 2000 14.0 20 40 40 1000 2000 60/5 7.2 12 24 48 48 360 720 2400 2400 16.8 24 48 48 1200 2400 3000 75/5 9.0 15 30 60 60 450 900 3000 3000 21.0 30 60 60 1500 80/5 9.6 16 32 64 64 480 960 3200 3200 2204 32 64 64 1600 3200 100/5 12.0 20 40 80 80 600 1200 4000 4000 28.0 40 80 80 2000 4000 120/5 14.4 24 48 96 96 720 1440 4800 4800 33.6 48 95 95 2400 4800 150/5 18.0 30 60 120 120 900 1800 6000 6000 42.0 60 120 120 3000 6000 200/5 24.0 40 80 160 160 1200 2400 8000 8000 56.0 80 160 160 4000 8000 250/5 30.0 50 100 200 200 1500 3000 10㎿ 10㎿ 70.0 100 200 200 5000 10㎿ 300/5 36.0 60 120 240 240 1800 3600 12 12 84.0 120 240 240 6000 12 400/5 48.0 80 160 320 320 2400 4800 16 16 112.0 160 320 320 8000 16 500/5 60.0 100 200 400 400 3000 6000 20 20 140 200 400 400 10㎿ 20 600/5 72.0 120 240 480 480 3600 7200 24 24 168 240 480 480 12 24 750/5 90.0 150 300 600 600 4500 9000 30 30 210 300 600 600 15 30 800/5 96.0 160 320 640 640 4800 9600 32 32 224 320 640 640 16 32 1000/5 120.0 200 400 800 800 6000 12㎿ 40 40 280 400 800 800 20 40 1200/5 144.0 240 480 960 960 7200 14.4 48 48 336 480 960 960 24 48 1500/5 180.0 300 600 1200 1200 9000 18.0 60 600 420 600 1200 1200 30 60 2000/5 240.0 400 800 1600 1600 12㎿ 24.0 80 80 560 800 1600 1600 40 80 2500/5 300.0 500 1000 2000 2000 15 30.0 100 100 700 1000 2000 2000 50 100 Characteristics 1. 정격을 초과하여 사용할 시에는 AC 110V, 5A 의 정격을 초과하여 사용시 PT, CT는 조합하여 사용하십시오. 2. 동작전압범위는 정격전압의 ±10% 이내입니다. 3. 최대 눈금은 위의 Standard Full Scale Table을 참조하여 사용하 십시오. 4. Watt Meter Transducer는 내부(INT.) 또는 외부(EXT.)형 2종류가 있습니다. /√ 3 )으로 표시합니다. 5. 3상 4선의 경우 상전압 (Vι MAX. scale value 6. 교 정 전 력 = PT ratio × CT ratio ex) 3P 3W full scale wattmeter : 600KW P.T ratio : 3300V/110V 210 600KW (3300/110)X(100/5) DEESYS TOTAL PRODUCTS GUIDE ex1) 3P 4W full scale wattmeter : 2000KW P.T ratio : 22900V √ 3 C.T ratio : 100A/5A calibrating watts = 1. Combine AC 110V P.T & AC 5A CT in case of over rating value. 2. Allowance of operating voltage is ± 10% of rating voltage. 3. For max scale. refer to the above Standard Full Scale Table. 4. Watt Meter Transducer is internal type and external type. 5. In case of 3�4W voltage in phase voltage(Vι/ √ 3) MAX. scale value 6. Calibrating Watt = PT ratio × CT ratio = 1.0KW 190V √ 3 C.T ratio : 50A/5A 2000KW calibrating watts = 22900V 190V ( √ 3 = ) √ 3 = 1.666KW X (50/5A) Panel Board Var Meter “W”type “S”type Specification Type Size Circuit Rated V VA A V Remark A V A Hz Class Weight (㎏) REF W8-R1 1P2W 110,220 5 0.5 0.5 - - 60 1.0/1.5 0.65 W8-R2 1P3W 110 5 0.5 0.5 - - 60 1.0/1.5 0.75 EXT. T/D W8-R3 80×80㎜ W8-R4 3P3W 110,220 5 0.5 0.5 B U 60 1.0/1.5 0.75 3P4W 190/ √ 3,380/ √ 3 5 0.5 0.5 B U 60 1.0/1.5 0.85 W8-R4U 3P4W 190/ √ 3,380/ √ 3 5 0.5 0.5 U U 60 1.0/1.5 0.90 W11-R1 1P2W 110,220 5 0.5 0.5 - - 60 1.0/1.5 0.70 W11-R2 1P3W 110 5 0.5 0.5 - - 60 1.0/1.5 0.85 EXT. W11-R3 3P3W 110,220 5 0.5 0.5 B U 60 1.0/1.5 0.85 T/D W11-R4 3P4W 190/ √ 3,380/ √ 3 5 0.5 0.5 B U 60 1.0/1.5 0.95 3P4W 190/ √ 3,380/ √ 3 5 0.5 0.5 U U 60 1.0/1.5 1.00 W11-R1T 1P2W 110,220 5 0.5 0.5 - - 60 1.0/1.5 0.60 W11-R2T 1P3W 110 5 0.5 0.5 - - 60 1.0/1.5 0.85 INT. W11-R3T 3P3W 110,220 5 0.5 0.5 B U 60 1.0/1.5 0.85 T/D W11-R4T 3P4W 190/ √ 3,380/ √ 3 5 0.5 0.5 B U 60 1.0/1.5 0.90 W11-R4UT 3P4W 190/ √ 3,380/ √ 3 5 0.5 0.5 U U 60 1.5 0.90 S8-R1 1P2W 110,220 5 0.5 0.5 - - 60 2.5 0.55 S8-R2 1P3W 110 5 0.5 0.5 - - 60 2.5 0.65 EXT. 3P3W 110,220 5 0.5 0.5 B U 60 2.5 0.65 T/D S8-R4 3P4W 190/ √ 3,380/ √ 3 5 0.5 0.5 B U 60 2.5 0.75 S8-R4U 3P4W 190/ √ 3,380/ √ 3 5 0.5 0.5 U U 60 2.5 0.85 S10-R1 1P2W 110,220 5 0.5 0.5 - - 60 1.5 0.57 S10-R2 1P3W 110 5 0.5 0.5 - - 60 1.5 0.67 EXT. T/D W11-R4U S8-R3 110×110㎜ 80×80㎜ S10-R3 3P3W 110,220 5 0.5 0.5 B U 60 1.5 0.67 S10-R4 100×84㎜ 3P4W 190/ √ 3,380/ √ 3 5 0.5 0.5 B U 60 1.5 0.77 S10-R4U 3P4W 190/ √ 3,380/ √ 3 5 0.5 0.5 U U 60 1.5 0.87 ※ U: Unbalance, T: Int.Transducer, R: VAR ※EXT.T/D: 트랜스듀서 외부설치용, INT.T/D: 트랜스듀서 내장형 ※ The specification of rating current 1A is based on ordering ※ 주문시 Hz선택 example scale ※The standard scale in lag scale ※set the var meter to lead in left side and to lag in right side from point if the var meter in used for the power factor DEESYS TOTAL PRODUCTS GUIDE 211 Panel Board Var Meter Standard full scale table(1/2 var meters) Phase Wire 1P2W 1P3W P.T.ratio(V) 110 110 Calibrating watts 3P 4W 220 380 /110 440 /110 3300 /110 6600 /110 22000 /110 22900 /110 0.5Kvar 1.0Kvar 0.5Kvar 0.48Kvar 154㎸ 208//√ 3 380/√ 3 /110 /190/√ 3 380 11400/√ 3 22900/ √ 3 /√ 3 /190/√ 3 /190/ √ 3 0.579Kvar 0.5Kvar 0.5Kvar 0.5Kvar 0.5Kvar 1.0Kvar 1.0Kvar 2.0Kvar 0.833Kvar 5/5 0.3 0.5 1 2 2 15 30 100 100 700 1 2 2 20 100 10/5 0.6 1 2 4 4 30 60 200 200 1400 2 4 4 100 200 C.T.ratio 0.3Kvar 3P 3W 0.833Kvar 15/5 0.9 1.5 3 6 6 45 90 300 300 2100 3 6 6 150 300 20/5 1.2 2 4 8 8 60 120 400 400 2800 4 8 8 200 400 25/5 1.5 2.5 5 10 10 75 150 500 500 3500 5 10 10 250 500 30/5 1.8 3 6 12 12 90 180 600 600 4200 6 12 12 300 600 40/5 2.4 4 8 16 16 120 240 800 800 5600 8 16 16 400 800 50/5 3.0 5 10 20 20 150 300 1000 1000 7000 10 20 20 500 1000 60/5 3.6 6 12 24 24 180 360 1200 1200 8000 12 24 24 600 1200 75/5 4.5 7.5 15 30 30 225 450 1500 1500 105Mvar 15 30 30 750 1500 80/5 4.8 8 16 32 32 240 480 1600 1600 11.2 16 32 32 800 1600 100/5 6.0 10 20 40 40 300 600 2000 2000 14.0 20 40 40 1000 2000 120/5 7.2 12 24 48 48 360 720 2400 2400 16.3 24 48 48 1200 2400 150/5 9.0 15 30 60 60 450 900 3000 3000 21.0 30 60 60 1500 3000 200/5 12.0 20 40 80 80 600 1200 4000 4000 28.0 40 80 80 2000 4000 250/5 15.0 25 50 100 100 750 1500 5000 5000 35.0 50 100 100 2500 5000 300/5 18.0 30 60 120 120 900 1800 6000 6000 42.0 60 120 120 3000 6000 400/5 24.0 40 80 160 160 1200 2400 8000 8000 56.0 80 160 160 4000 8000 10Mvar 500/5 30.0 50 100 200 200 1500 3000 10Mvar 10Mvar 70 100 200 200 5000 600/5 36.0 60 120 240 240 1800 3600 12 12 84 120 240 240 6000 12 750/5 45.0 75 150 300 300 2250 4500 15 15 105 150 300 300 7500 15 800/5 48.0 80 160 320 320 2400 4800 16 16 112 160 320 320 8000 16 1000/5 60.0 100 200 800 800 3000 6000 20 20 140 200 400 400 10Mvar 20 1200/5 72.0 120 240 480 480 3600 7200 24 24 168 240 480 480 12 24 1500/5 90.0 150 300 600 600 4500 9000 30 30 210 400 600 600 150 30 2000/5 120.0 200 400 800 800 6000 12Mvar 40 40 280 400 800 800 20 40 2500/5 150.0 250 500 1000 1000 7500 15 50 50 350 500 1000 1000 25 50 Characteristics 1. 정격을 초과하여 사용할 시에는 AC 110V, 5A의 PT, CT를 조합하 여 사용하십시오. 2. 동작전압범위는 정격전압의 ± 10% 이내입니다. 3. 최대 눈금은 위의 Standard Full scale Table 을 참조하여 사용하 십시오. 4. Var meter Transducer는 내부(INT.) 또는 외부(EXT.)형 2종류가 있습니다. 5. 3상 4선의 경우 상전압( √ 3 )으로 표시합니다. 6. 최대 눈금은 전부하용량의 1/2, 1/3, 1/4 로 선택하여 사용하십시오. MAX. scale value 6. 교 정 전 력 = PT ratio × CT ratio ex) 3P 3W full scale varmeter : 300KVar P.T ratio : 3300V/110V C.T ratio : 100A/5A calibrating Var = 212 300KVar (3300/110)X(100/5) DEESYS TOTAL PRODUCTS GUIDE = 0.5KVar 1. Combine AC 110V P,T & AC 5A C.T in case of over rating value. 2. Allowance of operating voltage is ± 10% of rating voltage. 3. For max scale. refer to the above standard full scale table. 4. Var meter Transducer is internal type and external type. 5. In case of 3�4W. the voltage in phase voltage (Vι/√ 3 ) 6. Select 1/2 or 1/3 or 1/4 value of total load capacity for max scale. MAX. scale value 7. Calibrating Watt = PT ratio × CT ratio ex1) 3P 4W full scale Var meter : 1000KVar 190V P.T ratio : 22900V √ √ 3 3 C.T ratio : 50A/5A 1000KVar calibrating Var = 22900V 190V ( √ ) X (50/5A) √ 3 3 = 0.833KVar Watt Meter, Var Meter External connection diagram �EXT. T/D type �INT. T/D type DEESYS TOTAL PRODUCTS GUIDE 213 Panel Board Power Factor Meter [COS ] “W”type “S”type Specification Type Size Circuit Rated VA V A V A Remark Hz Class Weight (㎏) 0.65 REF W8-P1 1P2W 110,220 5 0.5 0.5 - 50/60 3.0/5.0 W8-P2 1P3W 110 5 0.5 0.5 - 50/60 3.0/5.0 0.75 W8-P3B 3P3W 110,220 5 0.5 0.5 B 50/60 3.0/5.0 0.75 EXT. T/D W8-P3U 80×80㎜ 3P3W 110,220 5 0.5 0.5 U 50/60 3.0/5.0 0.85 3P4W 190/ 3,380/ 3 5 0.5 0.5 B 50/60 3.0/5.0 0.90 W8-P4U 3P4W 190/√ 3,380/ √ 3 5 0.5 0.5 U 50/60 3.0/5.0 0.90 W11-P1 1P2W 110,220 5 0.5 0.5 - 50/60 3.0/5.0 0.70 W11-P2 1P3W 110 5 0.5 0.5 - 50/60 3.0/5.0 0.85 W11-P3B 3P3W 110,220 5 0.5 0.5 B 50/60 3.0/5.0 0.85 EXT. W11-P3U 3P3W 110,220 5 0.5 0.5 U 50/60 3.0/5.0 0.95 T/D W11-P4B 3P4W 190/√ 3,380/ √ 3 5 0.5 0.5 B 50/60 3.0/5.0 1.00 W8-P4B 3P4W 190/√ 3,380/ √ 3 5 0.5 0.5 U 50/60 3.0/5.0 1.00 W11-P1T 1P2W 110,220 5 0.5 0.5 - 50/60 3.0/5.0 0.60 W11-P2T 1P3W 110 5 0.5 0.5 - 50/60 3.0/5.0 0.85 W11-P3BT 3P3W 110,220 5 0.5 0.5 B 50/60 3.0/5.0 0.85 INT. W11-P3UT 3P3W 110,220 5 0.5 0.5 U 50/60 3.0/5.0 0.90 T/D W11-P4BT 3P4W 190/√ 3,380/ √ 3 5 0.5 0.5 B 50/60 5.0 0.90 W11-P4UT 3P4W 190/√ 3,380/ √ 3 5 0.5 0.5 U 50/60 5.0 0.90 S8-P1 1P2W 110,220 5 0.5 0.5 - 50/60 5.0 0.55 0.65 W11-P4U 110×110㎜ S8-P2 1P3W 110 5 0.5 0.5 - 50/60 5.0 3P3W 110,220 5 0.5 0.5 B 50/60 5.0 0.75 EXT. S8-P3U 3P3W 110,220 5 0.5 0.5 U 50/60 5.0 0.85 T/D S8-P4B 3P4W 190/√ 3,380/ √ 3 5 0.5 0.5 B 50/60 5.0 0.85 S8-P4U 3P4W 190/√ 3,380/ √ 3 5 0.5 0.5 U 50/60 5.0 0.57 S10-P1 1P2W 110,220 5 0.5 0.5 - 50/60 5.0 0.67 S8-P3B 80×80㎜ S10-P2 S10-P3B 100×84㎜ 1P3W 110 5 0.5 0.5 - 50/60 5.0 0.67 3P3W 110,220 5 0.5 0.5 B 50/60 5.0 0.77 EXT. T/D S10-P3U 3P3W 110,220 5 0.5 0.5 U 50/60 5.0 0.87 S10-P4B 3P4W 190/√ 3,380/ √ 3 5 0.5 0.5 B 50/60 5.0 0.87 S10-P4U 3P4W 190/√ 3,380/ √ 3 5 0.5 0.5 U 50/60 5.0 0.87 ※ U:Unbalance, T:Int. Transduce, P:Power Factor. ※ EXT.T/D:External Transducer, INT.T/D:Internal Transducer ※ Order made is rating current 1A of meter ※ 주문시 Hz 선택 214 DEESYS TOTAL PRODUCTS GUIDE Panel Board Power Factor Meter[COS ] Feature 1. 정격을 초과하여 사용할 시에는 AC 110V, 5A의 PT, CT를 조합하 여 사용하십시오. 2. 동작전압범위는 정격전압의 ±10%이내입니다. 3. Power Factor meter, Transducer는 내부(INT.) 외부 (EXT.) 형 2종류가 있고 Balance형과 Unblance형으로 구분합니다. 4. 3상 4선의 경우 상전압(Vι /√ 3 )으로 표시합니다. 5. 2차 정격전류 5A의 10%인 소부하의 경우는 역률의 정상지시를 기 대할수 없으며 정격전류의 1/3 이상이 되어야 정확한 오차가 보증 됩니다. 6. 역률계의 Standard scale의 LEAD 0.5~1.0 ~ 0.5 LAG입니다. 1. Combine AC 110V. PT & AC 5A C.T in case of over rating value 2. Allowance of operating voltage is ± 10% of rating voltage. 3. Power Factor meter. Transducer can be classified 2type (internal and external) and it can be classified 2 type (Balance and unbalance) 4. In case of 3�4W, voltage is phase voltage (Vι /√ 3) 5. On over 1/3 value of rating current. it is certified the error correctly because it is not expected normal indication of power factor in case of 10% load of rating 2ry current 5A. 6. The standard scale of power factor meter is Lead 0.5~1.0~0.5 lag External connection diagram �EXT. T/D type �INT. T/D type DEESYS TOTAL PRODUCTS GUIDE 215 Panel Board Frequency Meter “W”type “S”type Specification Type Size Rated Voltage (V) VA Class Weight(Kg) 1.0 0.33 110.220 2.0 1.0 0.45 W8-F 80X80mm W11-F 110X110mm S8-F 80X80mm 1.0 0.10 S10-F 100X84mm 1.0 0.20 ※F : Frequency Characteristics 1. 주파수의 Standard full scale은 45Hz~55Hz, 55Hz~65Hz 2종 류가 있습니다. 2. 정격전압을 초과할 경우는 외부 P.T를 조합하여 사용하십시오. 3. 동작전압의 범위는 AC 110V: 80~120V, AC220V: 160~240V입 니다. 4. 주파수 METER의 Pointer는 Needle type입니다. External connection diagram 216 DEESYS TOTAL PRODUCTS GUIDE 1. Standard full scale of frequency meter in 2 types : 45HZ~55HZ and 55HZ~65HZ 2. Combine P.T in outside in case of over the rating voltage. 3. Allowance of operating voltage in 80~120V for AC 110V and 160~240V for AC 220V 4. Pointer of power factor meter in needle type. Panel Board Maximum Demand Meter [V0] 특징 이 Vo 메타는 기계식과 전자식을 겸한 영상전압지시계이며, 현재의 값은 기계식 아나로그 값으로 지시합니다. Vo 값이 변동할 때 마다 Peak를 EEPROM에 기억 하게하고 그 값은 메터 밑 부분에 있는 3 digital FND Display에 나타납니다. 본 전자형은 관성에 의한 오차가 없으므로 보다 정확히 그 Peak치를 확인할 수 있습니다. Feature The Vo meter is a electronic type for demand Vo. which is displayed by 3 digit FND window on the lower part of the meter with mechanical type indicatior for real time Vo value. Comparing with mechanical type. the Electronic Vo meter no slip error against inertia moment of indicating needle set. Application 적용 이 Vo메타는 1선 지락시 접지 전류량이 작아 전류요소로 접지 상태를 파악 할 수 없는 장소에 전원측 PT의 2차측을 Open-Delta 결선하여 이 메타에 연결, 사용합니다. 사용법 The Vo meter is application for detecting zero sequence voltage on the distribution line which has small ground current. As soon as one phase is grounded by fault. zero phase sequence voltage is generated, For the purpose, the meter would be connected with Open-Delta circuit of 3 phase PT secondary. Description 1. 아래의 결선도에서와 같이 결선합니다. 2. 외장형 재충전용 밧데리를 메터에 연결합니다. 3. 3상 전원을 살립니다. 4. 선로에 영상 전압이 발생하면 광각형 지시계기에 현재의 영상 전압 을 지시합니다. 이 값은 현재의 값이므로 선로의 상태 변경에 따라 변합니다. 5. 영상 전압의 크기가 최대값이 되면 그 값은 3digit Display에 나타 나며 EPROM에 저장 됩니다. 최대값이 되면 갱신 될 때 마다 Display 값은 상향 지시 합니다. 6. 표시된 최대치는 Display 오른 쪽에 있는 Reset Button 을 누르면 영구히 지워 집니다. 7. 영상전압이 10V 미만에서는 최대치를 표시하지 않습니다. 1. To connect a meter as shown below 2. To connect the meter with external rechargeable battery 3. To enerzise source PT 4. The wide range analog indicator will indicate real time Vo voltage. If any on the line. The indicating value will move according to real time line situation, 5. The demand value on the Display with 3 digit FND located lower part of the front plate of the meter, is shown a fixed peak vaule. The value is stored in a EEPROM in the meter. Whenever new peak vaule is generated, the vaule is renewed instead of the old data. 6. The Display is errassed by pressing reset button on the right side of the Display. 7. Demand display is designed to be indicated to be indicated for higher than 10Volt. 사양 Item Model Rating (AC) Full Scall Accuracy (%) Aux.Power (AC) Freq. (Hz) Burden (VA) Weight (Kg) Vo Meter W11 DVA 110/190 150/259 1.5 at FS 110V/190V 60 0.5 1.0 External connection diagram Dimension for External Power supply Box Dimension for Meter DEESYS TOTAL PRODUCTS GUIDE 217 Panel Board Maximum Demand Meter [A0] 특징 이 Ao메타는 기계식과 전자식을 겸한 영상전류지시계이며, 현재의 값 은 기계식 아나로그 값으로 지시합니다. Ao값이 변동할 때마다 Peak 치를 EEPROM에 기억 하게하고 그 값은 메터 밑 부분에 있는 3 digit FND Display에 나타납니다. 이 전자형은 관성에 의한 오차가 없으므 로 보다 정확히 그 Peak치를 확인할 수 있습니다. Feature The Ao meter is a electronic type for demand Ao. which is displayed by 3digit FND window on the lower part of the meter with mechanical type indicatior for real time Ao value. Comparing with mechanical type, the Electronic Ao meter no slip error against inertia moment of indicating needle set. Application 적용 이 Io메타는 계통사고 또는 비정상시 발생하는 영상전류를 측정하는 메타로, 직접 접지 또는 저항접지 계통에 적용하며 ZCT 또는 3 CT의 중성선에 연결하여 사용합니다. 사용법 The lo meter is applied for detecting zero sequence current on the distribution live which is ground solidly or with resistance. As soon as one phase is grounded by fault. zero phase sequence current is generated. For the purpose. the meter would be connected with a ZCT or neutral line of 3 CT connection. Description 1. 아래의 결선도에서와 같이 결선 합니다. 2. 외장형 재충전용 밧데리를 메터에 연결합니다. 3. 3상 전원을 투입시킵니다. 4. 선로에 영상 전류가 발생하면 광각형 지시계기에 현재의 영상 전류 를 지시합니다. 이 값은 현재의 값이므로 선로의 상태 변화에 따라 항상 변합니다. 5. 영상 전류의 크기가 최대값이 되면 그 값은 3 Digit Display에 타 나나며 EEPROM에 저장 됩니다. 최대값이 되면 갱신 될 때 마다 Display 값은 갱신된 값을 지시합니다. 6. 표시된 최대치는 Display 오른쪽에 있는 Reset Button을 누르면 영구히 지워집니다. 1. To connect a meter as shown below. 2. To Connect the meter with external rechargeable battery 3. To be flow unbalanced current at the relay terminal as the below diagram. 4. The wide range analog indicator will indicate real time lo current. The indicating value will move according to real time unbalanced line current. 5. The demand value on the Display with 3 digit FND located lower part of the front plate of the meter, is shown a fixed peak value. The value is stored in a EEPROM in the meter. Whenever new peak value is generated. the value is renewed instead of the old data. 6. The Display is errassed by pressing reset button on the right side of the Display. 사양 Item Model Rating (A) Full Scall (A) Accuracy (%) Aux.Power (AC) Freq. (Hz) Burden (VA) Weight (Kg) Ao Meter W11 DAA 1 or 5 1 or 5 1.5 at FS 110V/190V 60 0.5 1.0 ※주문시 ㎐ 선택 External connection diagram Dimension for Meter 218 DEESYS TOTAL PRODUCTS GUIDE Dimension for External Power supply Box Panel Board Meter Dimension UNIT : m/m �Wide angle type (80 x 80mm) �Wide angle type (110 x 110mm) �Square type (80 x 80mm) �Square type (100 x 84mm) DEESYS TOTAL PRODUCTS GUIDE 219 Panel Board Meter Dimension UNIT : m/m �INT. T/D (watt,var, unbalance type P.F meter, Demand meter) �INT. T/D (balance type P.F meter) �W11 type meter relay(110×110m) 220 DEESYS TOTAL PRODUCTS GUIDE 3상 절환형 각형 지시전기계기 [교류전압 전류계] KSC-1303 JIS C 1102 Model 특징 ∙ 단상 3선 또는 3상3선식 회로에서 각상의 상태를 전면부에서 직접 절환하여 전압, 전류를 볼 수 있는 계기입니다. ∙ AS, VS 스위치 가 필요 없으므로 공간 활용 및 배선 작업이 간편 하고 스위치로 인한 문제발생 요인을 제거하였습니다. ∙ 판넬 취부가 용이하도록 설계되어있습니다. ∙ 주위 환경에 대해 높은 신뢰성을 가지고 있습니다. ∙ 전류가 5A 초과시에는 변류기를 조합하여 사용하십시오. ∙ 회로 전압이 300V를 초과 사용시에는 VT를 사용 하십시오. S8 - S V A AC Voltage Phase Selection Square Type(80mm) Specification Part Name 3Phase Selection type panel Board Meter(V,A) Item Volt Meter(V) Ampere Meter(A) Type S8-SVA S8-SAA Accuracy ±2.5% ±2.5% Rating AC 150V, 300V AC 5A or 1A Input burden 0.5VA 1.5VA Frequency 동작원리 AC 50/60㎐ Rectifier(정류형) Moving lron type(가동철편형) 스위치 내구성 정격전류 인가하여 스위치 절체시 10,000회 절연저항 회전기회로와 외함간 500V Megger 100㏁ 이상 내전압 전기회로와 외함간 AC 2000V/MIN 재질 Cover:Poly cabonate(투명) 중량 Case:내열성 ABS(흑색) 0.3kg ※ 기타 계기에 대한 모든 적용 규격은 당사의 제품인 S8-VA, S8-AA와 같습니다. ※ 주문시 Hz 선택 DEESYS TOTAL PRODUCTS GUIDE 221 KSC-1303 JIS C 1102 3상 절환형 각형 지시전기계기[교류전압 전류계] Wiring Dimension 222 DEESYS TOTAL PRODUCTS GUIDE Digital Panel Meter General Specification Digital Panel Meter 96×48. Insulation Temperature � Insulation resistance at DC500V 100MΪ � Withstand voltage 2KV for 1 minuts between all terminals � Lightning impulse voltage 1.2/50μ s 4.5kV Display and Rating � � � � � � � Display range : 1999 4digit-LED 7 segment Digit Height : 14.22mm Color: Red Aux. power : AC 110/220V Frequency : 50/60Hz Outside dim. : 96×48×112mm Response time : less than 500ms � Operating temperature : 0~ 50℃ � Storage temperature : -20 ~ +70℃ Standard operating condition � � � � Temperature 0~50℃ Humidity 5~85% Aux. supply ±10% Power harmonic sine wave 10% Example of Application Direct type With TD type(Analog입력) Communication type DEESYS TOTAL PRODUCTS GUIDE 223 Digital Panel Meter [96 48mm] Specification Commercial type Panel Board Meter 96 X 48mm - DIN std. Part Name Digital Panel Meter Front view Type Connection Input Input burden Aux. power AC-A,V DC-A,V Hz CT or VT Direct. others VT A:0.1~10A A : 1㎃~10A AC 50~300V V;1~500V V : 50㎷~350 V40~70㎑ 0.3VA이하 A : 0.2V drop 0.3VA이하 V : 10㏁ AC110/220V±15%, 50/60㎐ 3VA 이하 Aux. power burden 3VA 이하 Display resolution 1.999/0.001, 19.99/0.01, 199.9/0.1, 1999/1 step Respons time 1 sec 이하 Accuracy ±0.5% + 1digit Display range 1999 4 digit-LED 7 segment Display color Red Terminal withstand Current : for 5sec 20×In capability Voltage : for 5sec 1.5×Vn Temperature Operating temperature 0~50℃ RH<95% Storage temperature -20~+70℃ Mounting Flush mounted type Insulation resistance DC 500V Megger 100㏁ More-between all terminals Withstand voltage 2㎸ for 1 minuts - between all terminals Lightning impulse withstand voltage Vibration Shock Weight 224 DEESYS TOTAL PRODUCTS GUIDE 1.2/50㎲ 4.5㎸ Vibration frequency:16.7㎐ Double amplitude:0.4㎜ Direction:horizontal, vertical, transerse Shock acceleration : 50G Shock application Direction : horizontal, vertical, transverse Shock times : 3 times 350g Digital Panel Meter [96 48mm] Ordering Code D D : Direct(직가) A : analog(입력) Digital Meter 9:W96mmXH48mm AA : AC Ammeter(A) AV : AC Voltmeter(V) DA : DC Ammeter(A) DV : DC Voltmeter(V) WT : Watt(W) VR : var(var) PF : PowerFactor(cosφ ) HZ : Frequency(㎐) (50,60㎐선정) WH : kWhr meter VH : kVarh meter 01 : Ampere-(19.99A,199.99A, 1999A중 선택) 02 : Volt-AC0~500V(500V이상의 경우는 보조 PT사용) 03 : DC 1㎃~10A(F.S지정) 04 : DC 50㎃~350V(F.S지정) 05 : DC 4~20㎃(With TD-F.S는 주문에 의함) 06 : DC 4~20㎃(With TD-F.S는 Program 방식) Digital Panel Meter 96X48mm Ammeter는 직접 Line에 연결하여 사용하는 type과 계장용 Transducer와 조합하여 사 용되는 type RS-485를 이용한 통신방식으로 나누어지며 전면에서 사용조건에 맞도록 Program으로 설정이 가능합니다. CT의 정격은 1 또는 5A 이며 True rms 방식을 채택 하였습니다. AC Ammeter Ordering Procedure Model Display Connection Accuracy D9AA-D01 D9AA-A05 Aux.Power 19.99A, 199.9A, 1999A선택(Input 5A) Direct(직가) 0.5% or 1 digit AC110/220V,50/60㎐ 1999,9999(4~20㎃) WithT/D-FS주문사양 0.5% or 1 digit AC110/220V,50/60㎐ Model Display Connection Accuracy Aux.Power D9AV-D02 19.99A,199.9A,1999A선택(Input Max.500V) Direct 0.5% or 1 digit AC110/220V,50/60㎐ D9AV-A05 1999,9999V(4~20㎃) WithT/D-FS주문사양 0.5% or 1 digit AC110/220V,50/60㎐ AC Voltmeter Ordering Procedure DEESYS TOTAL PRODUCTS GUIDE 225 Digital Panel Meter [96 48mm] DC Ammeter Ordering Procedure Model Display Connection Accuracy Aux.Power D9DA-D03 19.99A,199.9A,1999A선택(Input 1㎃~10A) D9DA-A05 1999,9999A(4~20㎃) Direct(직가) 0.5% or 1 digit AC110/220V,50/60㎐ WithT/D-FS주문사양 0.5% or 1 digit AC110/220V,50/60㎐ Model Display Connection Accuracy Aux.Power D9DV-D04 D9DV-A05 19.99A,199.9A,1999A선택(50㎷~350V) Direct(직가) 0.5% or 1 digit AC110/220V,50/60㎐ 1999,9999A(4~20㎃) WithT/D-FS주문사양 0.5% or 1 digit AC110/220V,50/60㎐ DC Voltmeter Ordering Procedure Watt, var, Power Factor-meter Ordering Procedure Item Watt Model Display D9WT-A05 1999,9999㎾(4~20㎃) D9WT-A06 D9WT-A05 Var D9WT-A06 0~999.9㎾(4~20㎃) Program setting (cos∅) D9PF-A05 D9PF-A06 0~999.9kvar(4~20㎃) 226 DEESYS TOTAL PRODUCTS GUIDE Aux.Power WithT/D 0.5% or 1 digit AC110/220V,50/60㎐ 0.5% or 1 digit AC110/220V,50/60H 0.5% or 1 digit AC110/220V,50/60㎐ 계장신호 WithT/D 계장신호 4㎃(-0.5)~12㎃(1)~20㎃(0.5) 4~20㎃ WithT/D 4㎃(-0.5)~12㎃(1)~20㎃(0.5) 계장신호 4~20㎃ Program set. P.F의 극성 표시는“-” 만 표시됩니다. Accuracy 1999,9999kvar(4~20㎃) Program setting PF Connection Digital Panel Meter [96 48mm] Hz meter Ordering Procedure Model D9HZ-D02 Display Connection 50㎐:40~60㎐ Direct 60㎐:50~70㎐(AC110) (직결 Max.300V) 50㎐:40~60㎐ D9HZ-D05 WithT/D-FS주문사양 60㎐:50~70㎐(4~20㎃) Accuracy Aux.Power 0.5% or 1 digit AC110/220V,50/60㎐ 0.5% or 1 digit AC110/220V,50/60㎐ kWhr, kVarh meter Ordering Procedure Model Display Connection Aux.Power D9WH-A08 999999 count WithT/D-계장신호(dry contact) AC110/220V Dimension Terminal connection Wiring Ampere Volt DEESYS TOTAL PRODUCTS GUIDE 227 Current and Voltage Transformer ■Round Type Current Transformer [1.15kV] ■Winding Type Current Transformer [1.15kV] ■Square Type Current Transformer [1.15kV] ■Voltage Type Transformer [0.72kV] ■Busbar Type Current Transformer [3.45-7.2kV] ■Square WindowType Current Transformer [3.45-7.2kV] ■Voltage Transformer [3.45-7.2kV] ■Ground Type Voltage Transformer [3.45-7.2kV] ■Round Type Zero PhaseCurrent Transformer [3.45-7.2kV] ■Epoxy Resin Insulator [0.6kV] ■Epoxy Resin Insulator [7.2, 12kV] ■Epoxy Resin Insulator [24, 36kV] ■Shunt [Voltage Drop 50mV] ■Current Limit Resister [CLR] CT, VT (저압, 고압,) 절연애자 (0.6kV, 7.2kV, 12kV, 24kV, 36kV) Round Type Current Transfomer [1.15kV] KSC-1706 DR-1, DR-2, DR-3, DR-18 ∙Resin : ABS Non-flamable(case) ∙Mold : Polyester ∙Cable through type ∙Mounting parts to be changeable at 90。 direction ∙For metering application ∙For indor ∙Color : Brown ∙케이블 관통형 ∙취부방향 90。회전가능 ∙일반 계기용 ∙옥내용 ∙케이스 ABS 난연성 ●정격 Ampere turn이란? 정격 AT는 정격 1차전류“A” 에 1차도체의 관통회수 ” T”를 곱한 값 을 나타냅니다. 따라서 1차도체를 달리하면 여러 가지의 정격 1차전류를 얻을수 있 습니다. [예] 정격 AT가 200AT 인 경우 관통수 1T 정격 1차 전류 200A 의 회로에 사용할수 관통수 2T 정격 1차 전류 100A 있습니다. 관통수 4T 정격 1차 전류 50A ●Specification Type Rated (AT) Burden (VA) Class (%) 5 1.0 Over Frequen Current -cy Strength (Hz) (times) Weight (kg) 75 100 DR-18 120 150 200 100 ●What is rating ampere turn? The rating A.T is the value of rating 1ry current(A) a multiplies the turn of 1ry conductor. According to the method how the turn of 1ry conductor is changed. It is able to change rating 1ry current. ex) In case of rating AT : 200 AT The turn of cable 1T :rating 1ry current 200A The turn of cable 2T :rating 1ry current 100A The turn of cable 4T :rating 1ry current 50A Refer to page 231 for the turn and cross area of 1’ ry conductor according to rating 1’ ry current. 120 150 160 DR-1 0.55 5 1.0 180 or 200 3.0 240 250 5 or 15 300 40In 50/60 240 250 DR-2 15 1.0 300 0.75 400 500 15 or 40 600 500 ●Dimension 600 230 Type A B ∅C ∅D E F G DR-18 84 48 18 64 65 80 50 DR-1 95 55 27 70 75 94 40 DR-2 108 65 40 87 75 94 40 1200 DR-3 134 77 60 114 75 94 40 1500 DEESYS TOTAL PRODUCTS GUIDE 750 DR-3 800 1000 15 or40 1.0 1.10 Round Type Current Transfomer [1.15kV] KSC-1706 ●DR CT 1차 도체 관통회수에 따른 전류비와 1차도체 단면적 다음 표는 정격 1차 전류와 1차 도체 관통회수 및 관통가능한 600V 비닐 전선(600V Ⅳ 전선)의 최대공칭 단면적을 기재하였습니다. 이 표의 값은 주위온도 40℃에서 전선의 허용 전류를 표시하였습니다. Rated AT 75 100 150 160 180 200 250 300 5VA 15VA DR-1 / DR-18 DR-2 1ry current (A) turns (T) 5 15 25 75 5 10 20 25 50 100 15 25 30 50 75 100 10 20 40 80 160 10 20 30 60 90 180 20 25 40 50 100 200 25 50 125 250 50 60 75 100 150 300 15 5 3 1 20 10 5 4 2 1 10 6 5 3 2 1 16 8 4 2 1 18 9 6 3 2 1 10 8 5 4 2 1 10 5 2 1 6 5 4 3 2 1 1ry cable (mm2) ( Rated AT ) 8 14 50 ) 8 14 14 22 200 8 14 14 38 50 200 8 14 38 50 200 8 14 22 50 60 200 8 14 22 38 50 200 8 14 50 200 14 14 22 38 50 200 240 ( 250 300 400 500 600 ●Current ratio and across area of 1ry conductor According to turn of DR. CT 1ry conductor Follwing table is discribed the trun rating 1ry current, 1ry conductor and the cross area of 600V vinyl wire(6000.I Wire) The allownace current of wire is the value at amboent temperaure 40℃ discribed. 40VA DR-3 1ry current (A) turns (T) 1ry cable (mm2) 15 20 30 60 120 240 25 50 125 250 30 50 75 100 150 300 40 50 100 200 400 50 100 125 250 500 70 100 150 200 300 600 16 12 8 4 2 1 10 5 2 1 10 6 4 3 2 1 10 8 4 2 1 10 5 4 2 1 8 6 4 3 2 1 5.5 14 22 80 125 500 14 60 125 500 22 38 80 80 125 500 14 22 80 200 500 14 60 80 125 500 22 60 80 100 125 500 Rated AT 500 600 750 800 1000 1200 1500 1ry current (A) turns (T) 50 100 125 250 500 75 100 150 200 300 600 75 150 250 750 80 100 200 400 800 100 200 250 500 1000 100 200 300 400 600 1200 150 300 500 750 1500 10 5 4 2 1 8 6 4 3 2 1 10 5 3 1 10 8 4 2 1 10 5 4 2 1 12 6 4 3 2 1 10 5 3 2 1 1ry cable (mm2) 38 125 125 250 500 60 60 125 150 250 500 38 125 250 500 38 50 125 250 500 38 125 125 250 500 38 125 125 ( ) 80×3( 250×3( 38 125 250 80×3( 250×3( ) ) ) ) ●DR CT의 내경과 관통전선의 외경과의 관계 (ex)In case of DR-1type CT and 3 trun of 38㎟ outer cross lengh of 38㎟ will 11.5 The error 120 & 100AT is 0.3 class and then inner cross lengh of DP-50F CT is 27mm and the CTcan be used ㎟ DEESYS TOTAL PRODUCTS GUIDE 231 Winding Type Current Transfomer [1.15kV] DRW-15, DRW-40, DRB-1, DRB-2, DRBD-1, DRBD-2 ∙권선형 ∙일반계기용 ∙보통전력계량용 ∙케이스 ABS 난연성 ∙Winding type ∙Color : Brown ∙For metering ∙Resin : ABS Non-flamable(case) ∙For watt hour meter ∙Mold : Polyester ∙Changeable 90。at mounting direction ●Single ratio C.T DRW C.T Type Primary (A) 5~30 40~150 DRB-1 200~300 400~500 DRW-40 5~30 40~150 DRB-2 200~300 400~500 SeconBurden dary (VA) (A) Class (%) DRW-15 5 or 1 5 or 1 15 40 1.0 over curr. Frequdimen- Weight strenght ency Remark sion (kg) (times) (Hz) Fig 1 0.70 Terminal Type 40in 1.0 40in 50/60 50/60 Type Primary (A) 10~150 5~75 DRBD-1 200~300 100~150 400~500 200~250 10~150 5~75 200~300 DRBD-2 100~150 400~500 200~250 Fig1.5~30A(DRW C.T) SeconBurden dary (VA) (A) 5 or 1 Class (%) Primary curreent DRW-15 Fig 1 1.0 Terminal Type Fig 2 1.2 Busbar Type 5 or 15 Remark 0.92 1.0 40in 50/60 Fig 2 5 or 1 15 or 40 Busbar Type 1.35 Fig2. 200~500A(DRB C.T) Type Dimension A B D 80 100 90 100 118 102 5~30 DEESYS TOTAL PRODUCTS GUIDE Primary current(A) Dimension A 40~150 80 (20~75) DRB-1 200~300 80 DRBD-1 (100~150) 400~500 (200~250) 80 40~150 100 (20~75) DRB-2 200~300 100 DRBD-2 (100~150) 400~500 (200~250) 100 ※( 232 Busbar Type over curr. Frequdimen- Weight strenght ency sion (kg) (times) (Hz) Unit : mm DRW-40 0.85 ●Double ratio C.T DRB C.T Type Fig 2 B C D E F G H(∅) 100 60 125 100 25 3.2 6 100 60 135 105 30 6 10 100 60 155 115 30 6 12 118 70 135 110 25 3.2 6 118 70 145 115 30 6 10 118 70 165 130 40 6 12 )안의 전류값은 DRBD(Double Ratio)type 일때 적용 Square Type Current Transfomer [1.15kV]Busbar취부용 DS-1, DS-2, DS-3, DS-4, DS-5, DS-6 DSD-1, DSD-2, DSD-3, DSD-4, DSD-5, DSD-6 ∙부스바 관통형 ∙일반계기용 ∙옥내용 ∙케이스 ABS 난연성 ∙Busbar through type ∙Color : Brown ∙For metering ∙Resin : ABS Non-flamable(case) ∙For indoor ∙Mold : Polyester ●Single ratio C.T Type DS-1 DS-2 DS-3 DS-4 DS-5 DS-6 Primary (A) 100~150 200~300 300 400 500~600 600~1000 750~2000 1000~4000 2500~8000 Secondary (A) 5 or 1 Burden (VA) Class (%) 5 5 or 15 40 15 or 40 40 40 3.0 over curr. strenght (times) Frequency (Hz) Weight (kg) 1.3 40in 50/60 over curr. strenght (times) Frequency (Hz) 1.0 40 1.5 1.5 1.6 1.9 4.8 ●Double ratio C.T Type DSD-1 DSD-2 Primary (A) Secondary (A) Burden (VA) 200~100 5 300~150 5 400~200 5 Class (%) 3.0 Weight (kg) 1.3 500~250 1.5 600~300 DSD-3 DSD-4 800~400 1000~500 1200~600 2000~1000 15 5 or 1 (생산의뢰) 1.5 1.0 40in 50/60 1.6 40 2000~1000 DSD-5 2400~1200 3000~1500 1.9 40 4000~2000 DSD-6 Unit : mm 4.8 ●Double C.T Connection diagram Dimension Type DS-1, DSD-1 6000~3000 A B C D 44 110 80 10 DS-2, DSD-2 65 115 65 11 DS-3, DSD-3 85 135 70 13 DS-4, DSD-4 105 155 85 22 DS-5, DSD-5 130 212 126 41 DS-6, DSD-6 160 260 180 75 DS CT is designed how to install the busbar is very easy being used the installing metal. Busbar. DEESYS TOTAL PRODUCTS GUIDE 233 Square Type Current Transfomer [1.15kV]Panel취부용 DS-1, DS-2, DS-3, DS-4, DS-5, DS-6 DSD-1, DSD-2, DSD-3, DSD-4, DSD-5, DSD-6 ∙부스바 관통형 ∙일반계기용 ∙옥내용 ∙케이스 ABS 난연성 ∙Busbar through type ∙Color : Brown ∙For metering ∙Resin : ABS Non-flamable(case) ∙For indoor ∙Mold : Polyester ∙취부가 견고하므로 진동이 많은 곳에 사용하시기 바랍니다. ●Single ratio C.T Type DS-1 DS-2 DS-3 DS-4 DS-5 DS-6 Primary (A) 100 150~200 250~300 300 400 500~600 750~1000 1200~2000 2500~4000 3000~8000 Secondary (A) 5 or 1 Burden (VA) Class (%) 5 5 or 15 15 40 15 or 40 40 40 3.0 over curr. strenght (times) Frequency (Hz) Weight (kg) 1.3 1.0 40in 50/60 over curr. strenght (times) Frequency (Hz) 40 1.5 1.5 1.6 1.9 4.8 ●Double ratio C.T Type DSD-1 Primary (A) Secondary (A) 200~100 Burden (VA) 5 300~150 Class (%) 3.0 Weight (kg) 1.3 400~200 DSD-2 500~250 1.5 600~300 DSD-3 DSD-4 15 800~400 1000~500 1200~600 1.5 5 or 1 40in 1.0 2000~1000 50/60 1.6 2000~1000 DSD-5 2400~1200 3000~1500 40 1.9 4000~2000 DSD-6 234 DEESYS TOTAL PRODUCTS GUIDE 6000~3000 4.8 Voltage Transformer and Grounding Voltage Transformer [0.72kV] ∙단상 ∙계기용 및 계전기용 ∙옥내용 ∙케이스 ABS 난연성 ∙Single phase ∙Color : Brown ∙metering & relaying ∙Resin : ABS Non-flamable(case ∙For indoor ∙Mold : Epoxy ●Specification Name Type Rated voltage(V) 1’ry 2’ry 3’ry Burden(VA) 2’ry 2’ry 3’ry DP-50 DP-50F V.T DP-100 50 2.5 220 380 DP-100F DP-200 Frequ Voltage Weight -ency Factor 3’ry (Hz) (IEC-186) (kg) Accuracy Class 110 or 190 1.2Vn cont 100 3.2 440 - - 200 5.8 DP-200F DGP-100 1.0 ※ 주의 : 3차 권선의 open terminal 간의 부담이 정격 부단보다 많이 작게되면 잔류전압이 발생되어 계전기의 오동작 원인이 될 수도 있습니다. 사용부담을 정격 부담의 100~70%가 되도록하여 주 시기 바랍니다. ※ Note : It the burden of 3ry winding open terinal is less than rating burden. It may be the reason of relay malfunction due to remaining voltage. Please select the pit that applieable burden of PT will be 100~70% of rating burden. 50/60 50 3.2 DGP-100F DGP-200 220 3 190/ 3 100 DGP-200F GPT DGP-100T DGP-100TF DGP-200T DGP-200TF 380 3 or 440 3 110/ 3 5.8 100 190/3 or 110/3 50 3P 3.0C 1.2Vn cont 1.9Vn 30s 3.2 200 100 3.0C 5.8 ●Dimension Model A B C D E DP-50 100 102 30 75 77 DP-100/DGP-100 118 112 33 75 73 DP-200/DGP-200 166 126 37 82 142 DEESYS TOTAL PRODUCTS GUIDE 235 Busbar Type Current Transformer [3.45-7.2kV] ∙계기용 ∙For metering ∙계전기용∙For protective relay Dimension ∙Color : Brown ∙Resin : Lupoy Non-flamable (case) ∙Mold : Epoxy Specification Type Specificaton Standard KS C-1706 Max. Voltage 3.45kV/7.2KV Rated Burden 15, 40VA Accuracy Class 1.0/10P10 Frequency 50/60HZ Rating Model AHB-1 AHB-1R ※ Primary(A) Secondary(A) Class(%) Burden(VA) Over Current 1.0 40 - 1.0/10P10 15 n〉 10 Over curr.strength Weight(kg) 40 times 4.0 5~300 5 Primary(A) A B C D E F 5~300 187 100 110 35 66 4 Dimension Model AHB-1 AHB-1R ※ *R: For Protective Relay 236 DEESYS TOTAL PRODUCTS GUIDE Square Window Type Current Transformer [3.45-7.2kV] ∙계기용 ∙계전기용 ∙부스바관통형 ∙For metering ∙For protective relay ∙Bus bar through Dimension ∙Color : Brown ∙Resin : Lupoy Non-flamable(case) ∙Mold : Epoxy Unit: mm Model A B C D E AHS-1/AHSD-1 146 145 92.5 10 65 AHS-2/AHSD-2 186 155 97.5 20 105 Specification (Single Ratio) Type Specificaton Standard KS C-1706 Max. Voltage 3.45kV/7.2KV Rated Burden 15, 40VA Accuracy Class 1.0/10P10 Frequency 50/60HZ Rating (Single Ratio) Model 1ry current(A) AHS-1 300~600 AHS-2 750~2000 AHS-1R ※ AHS-2R ※ 400~600 750~2000 2ry current(A) Class(%) Burden(VA) Over Current consrant Over curr.strength 5 or 1 1.0 5 or 1 1.0/10P10 2ry current(A) Class(%) Burden(VA) 1.0 40 - 5.0 1.0 40 - 5.0 1.0/10P10 15 n〉 10, n〉 5 1.0/10P10 15 n〉 10, n〉 5 40 - 40 - 15 n〉 10 15 n〉 10 40 times Weight(kg) 5.0 *R: For Protective Relay Rating (Double Ratio) Model AHSD-1 AHSD-2 AHSD-1R※ AHSD-2R※ 1ry current(A) 400~600 200~300 800~2000 5 or 1 400~1000 400~600 200~300 800~2000 400~1000 5 or 1 Over Current consrant Over curr.strength 40 times Weight(kg) 5.0 5.0 *R: For Protective Relay DEESYS TOTAL PRODUCTS GUIDE 237 Voltage Transformer [3.45-7.2kV] Dimension ∙계기용 ∙For metering ∙계전기용 ∙For protective ∙Color : Brown ∙Resin : Lupoy Non-flamable (case) ∙Mold : Epoxy Type A B C D E F AHP-1 125 160 223 107 55 87 138 160 223 107 55 98 AHP-2 AHP-3 Specification Type Specificaton Standard KS C-1706 Max. Voltage 3.45kV/7.2kV PRI. Voltage 3,300 or 6,600V Accuracy Class 1.0/ 3.0 Frequency 50/60HZ Secondary Voltage 110V Rating(Single ratio) 238 Model 1ry current(A) 2ry current(A) Class(%) Burden(VA) Weight(kg) AHP-1 3300~6600 110 1.0 50 8 AHP-2 3300~6600 110 1.0 100 10 AHP-3 3300~6600 110 3.0 200 10 DEESYS TOTAL PRODUCTS GUIDE Ground VoltageTransformer [3.45-7.2kV] Dimension ∙계기용 ∙For metering ∙계전기용 ∙For protective ∙Color : Brown ∙Resin : Lupoy Non-flamable (case) ∙Mold : Epoxy Type A B C D E F AHGP-2 125 160 223 107 55 87 AHGP-3 138 160 223 107 55 98 Specification Type Specificaton Standard KS C-1706 Max. Voltage 3.45kV/7.2KV PRI. Voltage 3,300/ 6,600V Accuracy Class 1.0/3G Frequency 50/60HZ Secondary, third Voltage 110/3. 190/3 Rating(Single ratio) Model AHGP-2 AHGP-3 1ry Voltage(V) 2ry Voltage(V) 3ry Voltage(V) 3300/√3 or 190/√3 190/ 3 6600/√3 110/√3 110/ 3 3300/√3 or 190/√3 190/ 3 6600/√3 110/√3 110/ 3 Class(%) Burden(VA) Weight(kg) 2ry 3ry 2ry 3ry 1.0 3G 50 100 8 1.0 3G 100 200 10 ※ 주의 : 3차 권선의 open단자간의 사용부담이 정격 부담보다 작게되면 잔류전압이 발생되어 계전기의 오동작 원이이 될 수도 있습니다. 사용부담을 정격부담의 100~70%가 되도록하여 주시기 바랍니다. ※ Note : It the burden of 3ry winding open terminal is less than rating burden. It may be the reason of realy malfunction due to remaining voltage please select the pit applieable burden of P.T will be 100~70% of rating burden. DEESYS TOTAL PRODUCTS GUIDE 239 Round Type Zero Phase Sequence Current Transformer [3.45-7.2kV] ∙케이블 관통형 ∙방향성 계전기용 ∙옥내용 ∙Cable through type ∙Color : Brown ∙For SGR protective relay(induction)∙Resin : ABS Non-flamable(case) ∙For indoor type ∙Mold : Polyester Dimension Type A B C D ZT-1 177 70 175 95 ZT-2 220 110 220 120 Specification Type Specificaton Standard KS C-1706 Rated Impedance 10Ω(P.F : 0.5LAG) Accuracy Class “L”CLASS Frequency 50/60HZ Rating(Single ratio) 240 Model Rated current(A) Zero phase 1ry(mA) Zero phase 2ry(mA) error(mA) burden(Ω) ZT-1 5~300 200 1.5 1.5 (1.0-2.0) 10(PF : 0.5LAG) ZT-2 400~1200 200 1.5 1.5 (1.0-2.0) 10(PF : 0.5LAG) DEESYS TOTAL PRODUCTS GUIDE Epoxy Resin Insulators [0.6kV] ∙분전반, 배전반 제어반 등의 절연을 위하여 사용되는 EPOXY 수지로 된 절연지지 애자로 저압회로에 사용됩니다. unit: mm LGD-2010 LGD-266 LGD-260 LGD-C30 LGD-3030 30 2-M6 DP7 Rating LGD-2010 LGD-266 LGD-260 LGD-C30 LGD-3030 Rated Voltage (kv) 0.6 0.6 0.6 - 0.6 Power Frequency Withstand Voltage (kv) - - - - - Impulse Withstand Voltage (kv) - - - - - Power Frequncy Flashover Voltage (kv) - - - - - Impulse flashover Voltage (kv) - - - - - Tensile Strength (kg) - - - - - - 60 Contents Type Bending Strength (kg) - 30 30 Net Weight (kg) - 0.03 0.03 - 0.05 Leakage Distance (mm) - 26 26 - 30 Insulation Level - - - - - Remark - - - - - DEESYS TOTAL PRODUCTS GUIDE 241 Epoxy Resin Insulators [0.6kV] ∙분전반, 배전반 제어반 등의 절연을 위하여 사용되는 EPOXY 수지로 된 절연지지 애자로 저압회로에 사용됩니다. unit: mm LGD-4040 LGD-5040 LGD-5050 LGD-6040 LGD-6070 2-M10 DP14 Rating Contents Type LGD-4040 LGD-5040 LGD-5050 LGD-6040 LGD-6070 0.6 0.6 Rated Voltage (kv) 0.6 0.6 0.6 Power Frequency Withstand Voltage (kv) - - - - - Impulse Withstand Voltage (kv) - - - - - Power Frequncy Flashover Voltage (kv) - - - - - Impulse flashover Voltage (kv) - - - - - Tensile Strength (kg) 600 500 1200 500 1200 Bending Strength (kg) 60 60 200 60 360 Net Weight (kg) 0.14 0.13 0.17 0.18 0.55 Leakage Distance (mm) 40 57 58 60 65 Insulation Level - - - - - Remark - - - - - 242 DEESYS TOTAL PRODUCTS GUIDE Epoxy Resin Insulators [7.2kV] ∙분전반, 배전반 제어반 등의 절연을 위하여 사용되는 EPOXY 수지로 된 절연지지 애자로 고압회로에 사용됩니다. ∙전기적, 기계적 내구성이 우수합니다. unit: mm LGD-8030 LGD-8055 LGD-8075 LGD-8085 Rating Contents Type LGD-8030 LGD-8055 LGD-8075 LGD-8085 7.2 Rated Voltage (kv) 7.2 7.2 7.2 Power Frequency Withstand Voltage (kv) 22 22 22 22 Impulse Withstand Voltage (kv) 60 60 60 60 Power Frequncy Flashover Voltage (kv) 50 50 55 55 Impulse flashover Voltage (kv) 80 80 90 90 Tensile Strength (kg) 210 600 1200 2000 Bending Strength (kg) 60 180 360 720 Net Weight (kg) 0.25 0.39 0.77 0.95 Leakage Distance (mm) 110 110 122 127 6A 6A 6A 6A EIB6A2 EID6A2 EIF6A2 EIH6A2 Insulation Level Remark DEESYS TOTAL PRODUCTS GUIDE 243 Epoxy Resin Insulators [7.2kV] ∙분전반, 배전반 제어반 등의 절연을 위하여 사용되는 EPOXY 수지로 된 절연지지 애자로 고압회로에 사용됩니다. ∙전기적, 기계적 내구성이 우수합니다. unit: mm LGD-9075 LGD-9085 Rating Contents Type LGD-9075 LGD-9085 Rated Voltage (kv) 7.2 7.2 Power Frequency Withstand Voltage (kv) 22 22 Impulse Withstand Voltage (kv) 60 60 Power Frequncy Flashover Voltage (kv) 55 55 Impulse flashover Voltage (kv) 90 90 Tensile Strength (kg) 1200 2000 Bending Strength (kg) 360 720 Net Weight (kg) 0.78 0.88 Leakage Distance (mm) 132 137 6A 6A - - Insulation Level Remark 244 DEESYS TOTAL PRODUCTS GUIDE Epoxy Resin Insulators [12kV] ∙분전반, 배전반 제어반 등의 절연을 위하여 사용되는 EPOXY 수지로 된 절연지지 애자로 고압회로에 사용됩니다. ∙전기적, 기계적 내구성이 우수합니다. unit: mm LGD-11090 LGD-14586 LGD-145100 ※액상 Rating Contents Type LGD-11090 LGD-14586 LGD-145100 Rated Voltage (kv) 12 12 12 Power Frequency Withstand Voltage (kv) 28 36 36 Impulse Withstand Voltage (kv) 75 95 95 Power Frequncy Flashover Voltage (kv) 70 80 80 Impulse Flashover Voltage (kv) 120 125 125 Tensile Strength (kg) 2000 2000 3000 Bending Strength (kg) 900 600 1400 Net Weight (kg) 1.59 1.58 1.72 Leakage Distance (mm) Insulation Level Remark 170 192 225 10B 10A 10A EIJ10B2 EIJ10B2 - DEESYS TOTAL PRODUCTS GUIDE 245 Epoxy Resin Insulators [24kV] ∙분전반, 배전반 제어반 등의 절연을 위하여 사용되는 EPOXY 수지로 된 절연지지 애자로 특고압회로에 사용됩니다. ∙전기적, 기계적 내구성이 우수합니다. unit: mm LGD-21090 LGD-22075 LGD-22090 Rating Contents Type LGD-21090 LGD-22075 LGD-22090 Rated Voltage (kv) 24 24 24 Power Frequency Withstand Voltage (kv) 50 50 50 Impulse Withstand Voltage (kv) 125 125 125 Power Frequncy Flashover Voltage (kv) 115 115 115 Impulse flashover Voltage (kv) 170 170 170 Tensile Strength (kg) 2000 1500 2000 Bending Strength (kg) 600 240 600 Net Weight (kg) 2.12 1.49 2.22 Leakage Distance (mm) Insulation Level Remark 246 DEESYS TOTAL PRODUCTS GUIDE 330 340 340 20B 20B 20B EIG20B4 EIE20B2 EIG20B2 Epoxy Resin Insulators [24kV, 36kV] ∙분전반, 배전반 제어반 등의 절연을 위하여 사용되는 EPOXY 수지로 된 절연지지 애자로 고압회로에 사용됩니다. ∙전기적, 기계적 내구성이 우수합니다. unit: mm LGD-280100 LGD-310115 Rating Contents Type LGD-280100 LGD-310115 Rated Voltage (kv) 24 36 Power Frequency Withstand Voltage (kv) 60 70 Impulse Withstand Voltage (kv) 150 170 Power Frequncy Flashover Voltage (kv) 140 150 Impulse flashover Voltage (kv) 150 170 Tensile Strength (kg) 2000 2000 Bending Strength (kg) 600 600 Net Weight (kg) 4.3 5.2 Leakage Distance (mm) Insulation Level Remark 396 485 20A 30B EIG20A2 EIG30B2 DEESYS TOTAL PRODUCTS GUIDE 247 Shunt [Voltage Drop 50mV] Accuracy class : 1.0% 2’ ry drop voltage : DC 50mV DC 100mV용 적용시 당사와 Dimension을 협의하십시요. Dimension Division A B C D E F H Type 130 26 75 103 150 17 13 DST-1 120~200 139 30 75 103 160 24 17 DST-2 220~300 139 30 75 103 160 24 17 DST-3 Rating(DC A) 10~100 ● DST-4~7(400~750A) ● DST-10~30(1000~3000A) Dimension Division TYPE Rating(DC A) A DST-4 DST-5 DST-6 DST-7 DST-10 DST-12 DST-15 DST-20 DST-25 DST-30 400 500 600 750 1000 1200 1500 2000 2500 3000 40 50 50 60 70 80 90 100 100 100 ● DST-40(4000A) 248 ● DST-50(5000A) TYPE DST-40 DST-50 Rating(A) 4000 5000 DEESYS TOTAL PRODUCTS GUIDE Current Limit Resistor [CLR] 한류저항은 GPT 3차측, a, f간에 접속되어 사고시 1차측 중성선에 흐르는 전류(lg)를 조정하여 (통상 380mA) 유효 전류를 발생시켜 지락계전기 및 영상전압계를 동직시킵니다. 또한 GPT 3차 측(OPEN DELTA)에 발생하는 제3고조파 및 이상전위 발생을 억제시켜 줍니다. Current limit resistor(CLR) will make the grounding relay and zero voltage meter operate due to the current which in a djusted primary neutral side current when fault. And it will be connected with 3ry side of GPT between terminal “a” and terminal “f” and then it restrains the 3ry harm once voltage and abnormal potential. Specification MODEL 1ry voltage of GPT(KV) 3ry voltage of GPT(V) Resistance value(Ω) DCR-1 3.3 110 16 DCR-2 3.3 190 50 DCR-3 6.6 110 8 DCR-4 6.6 190 25 DCR-5 3.3, 6.6 110, 190 by order capacity ● How to calculate the resistor value (3300V, 6600V급에만 적용) Ig= E1 √3 × 1 n2 × 9 R 400W Ig= E1 √3 × 1 n2 × 9 Ig ※ Remark : 1. If max 3ry voltage of GPT is on CLR during 1 minute over, the E1= E2= √3 190 3 V R=25(Ω) Ig= R= CLR may be fired. 6.600V 6.600V √3 6.600V √3 × × 1 2 60 1 602 × 9 25 = 0.38(A) 9 × = 25(Ω) 0.38 2. In case og low voltage G.P.T. Please adjust the value of CLR to 100~70% loading value of rating burden on GPT 3ry open Ig : Ground Fault Current terminal. E1 : GPT 1ry voltage n : Voltage Ratio = Winding Ratio ※ 비고 : 1. GPT의 최고전압이 1분이상 인가되면 CLR이 소손될 우려가 있습니다. R : Limting Resister(Ϊ ) 2. 저압 GPT인 경우 3차 정격부담의 70~100%가 되도록 CLR 저항값을 조정 해서 사용하시기 바랍니다. ※ Remark : In case of low voltage GPT, the above formula can not be used ※ 비고 : 저압 GPT의 경우는 상기식을 적용할 수 없습니다. Dimension Unit : mm DEESYS TOTAL PRODUCTS GUIDE 249 Digital Electric& Electronics System (Formerly Known as DAIYUN Electronics Co., Ltd.) HEADOFFICE & FACTORY (R/D CENTER) ���-��� 경기도 김포시 대곶면 대능리 257-18 #257-18, Daenung-Ri, Daegod-Myeon, Kimpo-City, Gyunggi-Do, KOREA TEL: 031-987-8771, 996-5661~5 FAX: 031-987-9197, 996-5564 A/S PART TEL: 031-987-2420 http://www.deesys.com
© Copyright 2024 Paperzz